wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Manufacturing of sterile and non sterile products

Total questions: 25

Worksheet time: 49mins

Name
Class
Date
1.

Moist heat sterilisation kills microorganisms by

a)

oxidation

b)

disruption of DNA

c)

coagulation of cell wall proteins

d)

free radical formation

2.

You can select more than one options

Factors affecting Make or Buy Decision of medicines in hospital are...

a)

Quality

b)

Quantity

c)

Cost

d)

Patients condition

3.

Multidose parenteral containers must contain....

a)

Vehicle

b)

Antioxidant

c)

Antimicrobial agent

d)

Stabilizer

4.

This is an example of _______________ laminar flow station.

a)

Turbulence

b)

Horizontal

c)

Vertical

d)

Diagonal

5.

Statement -1 Manufacturing is the converting raw materials into finished goods.

Statement-2 value-adding process allowing businesses to sell finished products at a higher cost over value of raw materials

a)

Both are True

b)

Both are False

c)

Only statement 1 is true

d)

Only statement 2 is true

6.

Dry heat sterilisation kills microorganisms by

a)

DNA disruption

b)

excitation of covalent bonds

c)

pyrolysis and oxidation

d)

coagulation of cell wall proteins

7.

Statement-1-HEPA Efficiency testing done, Monthly

Statement-2-HEPA filter integrity testing (cold DOP testing) -Yearly

a)

Statement-1 is true

b)

Statement-2 is true

c)

Both are true

d)

Both are false

8.

Which of the following sources are potential contaminants of the clean room? Select one or more options-

a)

Human

b)

Raw material

c)

Air

d)

Processing method

9.

Laminar air flow provides....flow

a)

Unidirectional

b)

bidirectional

c)

multidirectional

d)

Any one of the above

10.

What is the sterilisation parameter of moist heat sterilisation?

a)

121°C for 20 min 15 lbs

b)

140°C for 4 hour 10 lbs

c)

160°C for 2 hour 20 lbs

d)

170°C for 1 hour 10 lbs

11.

Which of the images below is not an LVP preparation?

a)
b)
c)
d)
12.

Sterile Water for injection(SWFI) must be

a)

Sterile

b)

Pyrogen free

c)

Free from Visible particle

d)

All of the above

13.

Vegetable oil Sterilized by Hot air oven and not autoclave

a)

True

b)

False

14.

Antioxidants

a)

Prevent degradation against oxidation

b)

Not prevent rancidity of oils

c)

Both statements are true

d)

Both statements are false

15.

Which of the following NOT used as tonicity adjuster in parenteral preparation...

a)

NaCl

b)

Dextrose

c)

Glucose

d)

Mannitol

e)

Cresol

16.

In sterility test-Method-A- is Direct innoculation and Method-B- is Membrane Filtration

a)

True

b)

False

17.

You can select mulptiple answers.

LAL test is....

a)

Bacterial endotoxin test

b)

Used for testing pyrogens

c)

It is container clarity test

d)

None of the above

18.

Non staining iodine ointment is prepared by

a)

Emulsification

b)

Chemical Reaction

c)

Trituration-

d)

Fusion-

19.

Oil:water:gum ratio is .... for emulsions with fixed oils

a)

4:2:1

b)

3:2:1

c)

2:2:1

d)

1:2:1

20.

What does HVAC stand for?

a)

Heating, ventilation and air

b)

Heating, ventilation and air conditioning

c)

Heating , ventilation and air cooling

d)

Heating, ventilation and air solutions

21.

You can select multiple options-

Hot DOP testing is carried out to check...and.....

a)

HEPA filter efficiency

b)

Hepa Filter Integrity

c)

Performed yearly

d)

Performed 6 Monthly

22.

All the following are advantages of moist heat sterilisation except ________________.

a)

shorter duration

b)

performed at lower temperature than dry heat

c)

cost effective

d)

effective method

23.

Which sterilisation method is recommended for thermostable, large volume parenteral liquid?

a)

Dry heat

b)

Moist heat

c)

EtO

d)

Filtration

24.

Which sterilisation method is recommended for thermostable, dry powdered drugs?

a)

Dry heat

b)

Moist heat

c)

EtO

d)

Filtration

25.

What is the pH of human blood?

a)

5.5

b)

6.8

c)

7.4

d)

8.1