QUIZ AU680 SET B

Total questions: 30

Worksheet time: 17mins

Name
Class
Date
1.

Analyzer AU680 (photometric + ISE optional)?

a)

800

b)

1200

c)

600

d)

1600

2.

How many sample positions in the STAT Table?

a)

18

b)

22

c)

24

d)

25

3.

What is the suitable temperature for reagent compartment in AU680?

a)

2 - 4°C

b)

4 - 10°C

c)

4 - 12°C

d)

8 – 12 °C

4.

Selectivity Check should be performed after a successful ISE Calibration


The above statement is true or false?

a)

True

b)

False

5.

What is solution used for W1?

a)

2.0% Cleaning Solution

b)

0.5 M HCl

c)

2.0 % detergent

d)

1.0 M HCl

6.

How many samples can run on rack holder for AU680 in one time?

a)

150 Sample

b)

200 sample

c)

100 sample

d)

80 sample

7.

What are the important items need to be changed every time when performing W2?

a)

Reagent Probe and Sample Probe

b)

Sample Syringe and Reagent Syringe

c)

ISE solution and Detergent

d)

Pre Diluent Bottle (61), W2 bottle and DET -1 position (64). (3 bottles)

8.

How many cuvettes there is in AU680 Chemistry Analyzer?

a)

80

b)

153

c)

165

d)

145

9.

How many slots available in the STAT table?

a)

22 slots for sample, 4 for ISE, 1 for Maintenance (Clean), 2 for Reagent Blank (RB)

b)

22 slots for sample, 4 for ISE, 2 for Maintenance (Clean) ,2 for Reagent Blank (RB)

c)

23 slots for sample, 6 for ISE, 3 for Maintenance (Clean), 1 for Reagent Blank (RB)

d)

23 slots for sample, 6 for ISE, 3 for Maintenance (Clean), 3 for Reagent Blank (RB)

10.

What are solutions used for W2?

a)

0.5% Cleaning Solution

b)

1.0% Cleaning Solution

c)

1 M HCl

d)

1 M NaCl

11.

What is the correct sequence to perform an Emergency Stop and Restarting system?


1) Turn Off CPU

2) Push Emergency Stop Button

3) Push Reset Button

4) Push Power ON Button

a)

1 > 2 > 3 > 4

b)

2 > 1 > 3 > 4

c)

3 > 1 > 4 > 2

d)

4 > 3 > 2 > 1

12.

Which priming procedure need to be done after cleaning?

a)

Buffer Prime

b)

Prime Bypass

c)

Mid/Ref Prime

d)

Total Prime

13.

All the following considered as daily maintenance

a)

Inspect the syringes for leaks

b)

Inspect the wash solution roller pump for leaks

c)

Clean the pre-dilution bottles

d)

Inspect and clean mix bars

14.

14. These conditions require for re-calibrate EXCEPT

a)

Change detergent

b)

Change calibrator

c)

The QC is outside SD limit

d)

Change reagent

15.

You can load multiple bottles of the same reagent on the analyzer. The AU identifies each bottle as a sequence.


Up to how many bottle sequences of the same reagent can be on the analyzer at one time?

a)

4

b)

5

c)

6

d)

There are no limit

16.

What is the maximum average photocal reading that user needs to change photo lamp?

a)

0.1

b)

0.8

c)

0.9

d)

1.5

17.

Which of the following are the factors that affect a calibration result?

a)

Reagent Stability

b)

Calibrator preparation

c)

Quality Control preparation

d)

Parameter Set up

18.

Which of the following are the factors that affect a Quality Control result?

a)

Parameter

b)

Calibration

c)

Index

d)

Reagent

19.

Which of the following stability period for the ISE Reagents once open?

a)

ISE Reference – 2 months / ISE Buffer – 1 month / ISE Mid Standard – 2 months

b)

ISE Reference – 2 months / ISE Buffer – 2 months / ISE Mid Standard – 1 months

c)

ISE Reference – 3 months / ISE Buffer –2 months / ISE Mid Standard – 1 month

d)

ISE Reference – 1 months / ISE Buffer – 2 months / ISE Mid Standard – 1 month

20.

Which are following rack function is CORRECT

a)

Blue – Calibration

b)

Yellow – Reagent Blank

c)

Green – Emergency

d)

Orange – Repeat

e)

White – QC

21.

What are the position need to be changed every time before performing W2?

a)

W2 Position

b)

64

c)

61

d)

62

22.

Which position will be used for ISE calibration for serum?

a)

1

b)

2

c)

3

d)

4

23.

For ISE Selectivity check, we must placed Na+/K+Selectivity Check into position ...

a)

1

b)

2

c)

3

d)

4

24.

How many racks that applied in AU680?

a)

7

b)

5

c)

4

d)

6

25.

What solution will be placed in this position?

a)

Detergent

b)

Deionised water

c)

Cleaning Solution

d)

Serum standard

26.

What is the name of this component?

a)

Mix Bar

b)

Cuvette Wheel

c)

Sample probe

d)

Wash Nozzle

27.

What is the function of this button

a)

To rerun the QC

b)

To order QC same requisition as Calibration Requisition

c)

To monitor QC

d)

To run the QC sample

28.

All the statements about Wash 1 (W1) solution are true EXCEPT

a)

Concentration of W1 solution is 2% Wash Solution

b)

Also known as Sample Probe Wash Solution

c)

Use for Weekly Maintenance

d)

Positions for W1 solution is Position 64 & 65

29.

Based on the picture given, which position will be used to perform QC Immuno?

a)

1 & 2

b)

3 & 4

c)

5 & 6

d)

All position

30.

Which statements are TRUE about this component?

a)

One of the photometry components

b)

Mix the reagent and sample in cuvette

c)

Transfer the sample from tubes to cuvettes

d)

Source of light for measuring the reaction mixture