NEW
Font size
WorksheetsBP 344
Total questions: 50
Worksheet time: 26mins
What is B.P 344?
Economic and Socialized Housing Projects
Accessibility Law
Fire Code of the Philippines
Subdivision and Condominium Buyers Protection Decree
As per BP 344, all doors shall have a minimum clear width of ____.
0.90 m
0.80 m
1.00 m
0.75 m
With regards to stoplights, the flashing green period required for the disabled should be determined on the basis of walking speed of?
0.90 m / sec
1.20 m / sec
0.80 m / sec
6 seconds
Manual switch should be located from the latch side of the door about ____.
200 mm
300 mm
250 mm
350 mm
Manual switches should be positioned above the floor within ____.
1.20 m to 1.30 m
1.30 m to 1.40 m
1.15 m to 1.25 m
1.35 m to 1.45 m
The threshold shall be kept to a minimum; whenever necessary, thresholds and sliding door tracks shall be preferably ramped and have a maximum height of how many mm?
20 mm
30 mm
25 mm
35 mm
Recesses or turnabout spaces should be provided for wheelchairs to turn around or to enable another wheelchair to pass; these spaces shall have a minimum area of?
1.20 m to 1.20 m
2.50 m to 1.50 m
1.50 m to 1.50 m
2.70 m to 1.20 m
As per BP 344. what is the minimum width of accessible parking slot?
3.70 m
2.40 m
3.40 m
2.70 m
Regular busses shall have how many designated seats for disabled persons according to BP 344?
5 seats
6 seats
2 seats
4 seats
This is also known as the Magna Carta for Disabled Persons.
R.A 7277
R.A 727
R.A 2777
R.A 7217
As per BP 344, dropped curbs shall be ramped towards adjoining curbs with a maximum gradient of ____.
1:20
1:12
1:8
1:10
As per B.P 344, long extension of handrails should be provided at the start and end of ramps and stairs at how many mm?
400 mm
300 mm
500 mm
250 mm
Accessible water closet stalls shall have a minimum area of ____.
1.90 m x 2.00 m
1.70 m x 1.80 m
1.80 m x 1.90 m
1.60 m x 1.70 m
B.P 344 requires that a certain number of units in public housing shall be accessible and fully usable for disabled persons.
What is the percentage based on the total number of units?
10%
5%
15%
20%
Minimum dimensions of accessible elevators as per B.P 344?
1.20 m x 1.40 m
1.50 m x 1.40 m
1.10 m x 1.40 m
1.50 m x 1.80 m
As per B.P 344, ramps shall be equipped with curbs on both sides with a minimum height of ___.
600 mm
200 mm
1800 mm
100 mm
As per B.P 344, corridors shall have a minimum clear width of?
1100 mm
1200 mm
1250 mm
1350 mm
As per B.P 344, handrails shall be installed at how many meters above steps or ramps?
0.90 m and 0.70 m
0.90 m and 0.80 m
0.80 m and 0.70 m
0.80 m and 0.75 m
Urinals should have an elongated lip or through type.
The maximum height of the lip should be ___.
840 mm
480 mm
804 mm
408 mm
What is the minimum turning space of water closet stalls?
3.06 sqm
2.25 sqm
2.70 sqm
3.24 sqm
In order to aid visually impaired persons to readily determine whether a washroom is for men or for women, the signage for women's washroom door shall be?
equilateral triangle
square
circle
ellipse
As per B.P 344, the maximum height of lavatories should be?
700 mm
800 mm
500 mm
600 mm
As per B.P 344, handrails for protection at great heights may be installed at?
0.90 m to 1.40 m
0.90 m and 1.20 m
0.80 m to 1.60 m
1.00 m to 1.60 m
Control panels and the emergency system of accessible elevators shall be within reach of a seated person.
The centerline heights for the topmost buttons shall be between ____ from the floor.
1.00 m to 1.20 m
1.20 m to 1.30 m
0.90 m to 1.30 m
0.90 m to 1.20 m
As per B.P 344, what is the maximum ramp gradient?
1:10
1:3
1:12
1:15
Signs on walls and doors shall be located at a minimum height of ____.
1600 mm
1200 mm
1400 mm
1500 mm
As per B.P 344, what is the maximum length of a ramp?
12 m
6 m
15 m
30 m
Recesses or turnabout spaces should be provided for wheelchairs to turn around and shall be spaced at a maximum of ___.
10 m
12 m
6 m
3.50 m
Under B.P 344, which of the following is not considered as a special design elements for accessibility?
windows
corridors
doors and entrances
drinking fountains
threshold
Air conditioned buses shall have how many designated seats for disabled persons?
5
6
2
4
Passenger trains shall have how many designated seats for disabled persons according to B.P 344?
5
6
2
4
Airplanes shall have how many designated seats for disabled persons according to B.P 344?
5
6
2
4
As per B.P 344, what is the minimum width of a dropped curb?
800 mm
900 mm
700 mm
1000 mm
As per B.P 344, to prevent water from collecting at the walkway dropped curbs shall be sloped towards the roads with a maximum cross gradient of ___.
1:20
1:8
1:12
1:10
Longer ramps whose gradient is more than the maximum shall be provided with a landing not less then ___.
1.80 m
1.50 m
1.40 m
1.60 m
In lengthy and busy walkways, spaces should be provided at some point along the route so that a wheelchair may pass another or turn around.
These spaces should have a minimum dimension of ____ and should be spaced at a maximum distance of ____ between stops.
12.0 m, 1.50 m
1.20, 12.0 m
1.50 m, 6.0 m
1.50 m, 12.0 m
Any ramp with a rise greater than 0.20 m and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end from the foot of the ramp of minimum how many meters from the foot of the ramp?
1.80 m
1.50 m
1.40 m
1.60 m
What is the preferred design for the stairs considering users of crutches?
slanted thread
right angle stairs
open riser stairs
slanted nosing
As per B.P 344, the minimum period for the steady green (for pedestrian) should not be less than ___.
0.90 m / sec
1.20 m / sec
0.800 m / sec
6 seconds
Doors should be operable by a pressure of force not more than how many kg?
1 kg
2 kg
3 kg
4 kg
Doors along major circulation routes should be provided with a kick plate made of durable materials at a height of ___.
0.20 m to 0.30 m
0.30 m to 0.40 m
0.15 m to 0.25 m
0.35 m to 0.45 m
Accessible elevators should be located from the entrance and should be easy to locate with the aid sign of not more than ___.
60 m
30 m
45 m
15 m
Signs on walls and doors should be located at a minimum height of?
1600 mm
1200 mm
1400 mm
1500 mm
What is the minimum clear width of ramps?
1.10 m
1.20 m
1.30 m
1.40 m
As per B.P 344, what is the maximum height of water closets?
400 mm
350 mm
550 mm
450 mm
As per B.P 344, handrails will be provided on both sides of the ramp at the height of ___ from the ramp level.
0.70 m and 1.10 m
1.00 m and 1.20 m
1.00 m and 0.90 m
0.70 and 0.90 m
What is the minimum depth of central refuge?
2000 mm
1400 mm
1200 mm
1500 mm
A level area should be provided at the top and bottom of any ramp of not less than ____.
1.80 m
1.50 m
1.40 m
1.60 m
Turnabout spaces should also be provided at or within of every dead end within ___.
10 m
6 m
12 m
3.50 m
What is the minimum clear level space to be provided before and extending beyond a door as per B.P 344?
1.20 m x 1.20 m
2.50 m x 1.50 m
1.50 m x 1.50 m
2.70 m x 1.20 m
