Power System RASL Activity 6

Total questions: 40

Worksheet time: 20mins

Name
Class
Date
1.

which of these are symmetrical fault

a)

L-G

b)

L-L-G

c)

L-L

d)

L-L-L

2.

The component which provides a signal to circuit breaker under the fault condition:

a)

Isolator

b)

Fuse

c)

Relay

d)

CT

3.

The correct statement about Buchholz relay

a)

It can only be used with largely sized alternators

b)

It is installed with largely sized transformers which have no conservator tank

c)

It can detect incipient faults

d)

It should never be used with oil immersed transformers

4.

Buchholz relay is used to protect:

a)

ALTERNATOR

b)

INDUCTION MOTOR

c)

SYNCHRONOUS MOTOR

d)

TRANSFORMER

5.

____________________ is/are an instantaneous relay/s:

a)

PMMC type

b)

Shaded pole type

c)

Both of these

d)

None of these

6.

Plug setting multiplier is defined as the ratio of:

a)

Fault current in relay coil x Pick up current

b)

Fault current in relay coil / Pick up current

c)

Fault current in relay coil x Transformer secondary turns

d)

Fault current in relay coil / Transformer secondary turns

7.

High-speed circuit breakers result in:

a)

Increased stability of power systems

b)

decreased stability of power systems

8.

The basic purpose of a relay is to:

a)

Detect the fault

b)

Remove the fault

c)

Trip the circuit

d)

All of these

9.

In Electrical power protection schemes ______________ transformer is used:

a)

VT

b)

CAPACITIVE VOLTAGE TRANFORMER

c)

Both of these

d)

None of these

10.

The equipment which has lowest chances of fault occurrence:

a)

Alternator

b)

Transformer

c)

Switchgear

d)

Induction motors

11.

A definite time relay is ___________ the amount of current:

a)

Dependent on

b)

Independent of

12.

The extent of damage and injuries caused due to a shock depends on:

a)

Amount of current

b)

Path of the current

c)

Time for which current flows

d)

All of these

13.

Backup protection is installed to:

a)

Increase the protection reliability of the system

b)

To increase the speed of protection system

c)

Both of these

d)

None of these

14.

station type LA can discharge current of

a)

>100kA

b)

<100kA and >65kA

c)

<65kA

d)

none

15.

In which part of the power system has lowest voltage?

a)

Generation

b)

Distribution

c)

Transmission

d)

Grid

16.

Transmission line usually have highest voltage in the components of power system.

a)

True

b)

False

17.

How will you calculate the Per unit value?

a)

Base value/Actual value

b)

Actual value/Per unit value

c)

Per unit value/Actual value

d)

Actual value/Base value

18.

Base impedance of the power system is given as:

a)

(Base kV)2/Base MVA

b)

(Base kV)/Base MVA

c)

Base MVA/(Base kV)2

d)

None of these

19.

A generator is rated of of 10 MVA, and 33 kV. The base impedance will be

a)

2089 ohm

b)

100 ohm

c)

1089 ohm

d)

4089 ohm

20.

The unit for base impedance is in .......... ohm

a)

True

b)

False

21.

Use of high speed circuit breaker will actually increase the system stability.

a)

False

b)

True

22.

Which one of the following device is used for improving the power factor of the system:

a)

Synchronous Phase Modifier

b)

Shunt Reactor

c)

Series Reactor

d)

Asynchronous Generator

23.

In a transmission line system, the feeders act as input to _________

a)

a) distributors

b)

b) service mains

c)

c) transformer sub stations

d)

d) all of the mentioned

24.

Which sequence this ?

a)

Positive sequence

b)

Negative sequence

c)

Zero sequence

d)

All

25.

The operator a^2 is

a)

-0.5+j0.866

b)

-0.5-j0.866

c)

-1+j0.5

d)

-1-j0.5

26.

If a positive sequence current passes through a transformer and its phase shift is 30 degrees, the negative sequence current flowing through the transformer will have a phase shift of

a)

30 deg

b)

-30deg

c)

120 deg

d)

-120 deg

27.

The zero sequence impedances of an ideal star-delta connected transformer (star-grounded)

a)

looking from star side is zero and looking from delta side is infinite

b)

looking from star side is zero and looking from delta side is also zero

c)

looking from star side is infinite and looking from delta side is zero

d)

looking from star side is infinite and looking from delta side is zero

28.

What is the value of zero sequence impedance in line to line faults?

a)

Z0 = 1

b)

Z0 =  \infty  

c)

Z0 = 3 Zn

d)

Z0 = 0

29.

Which among these is the connection diagram for line to line faults?

a)

only a

b)

only b

c)

only c

d)

only d

30.

What is the expression for fault current in line to line fault?

a)

If = √3 * (Ea / Z1 + Z2)

b)

If = 3 * (Ea / Z1 + Z2)

c)

If = √3 * (Ea / Z1 + Z2 + Z0)

d)

If = 3 * (Ea / Z1 + Z2 + Z0)

31.

What are the terminal conditions in case of SLG fault, if the fault occurs in the phase A?

a)

Vb = 0, Ia = 0, Ic = 0

b)

Va = 0, Ib = 0, Ic = 0

c)

Va = 0, Ia = 0, Ic = 0

d)

Vb = 0, Ia = 0, Ib = 0

32.

What percentage of faults occurring is single line to ground fault?

a)

50 %

b)

60 %

c)

35 %

d)

70 %

33.

What are the types of unsymmetrical faults?

a)

Single line to ground fault

b)

Double line to ground fault

c)

Line to line fault

d)

All of these

34.

Positive, negative and zero sequence impedances of line are 2,2 and 5 pu respectively. Find self and mutual impedances respectively?

a)

1 and 3 pu

b)

3 and 1 pu

c)

2 and 2 pu

d)

2 and 5 pu

35.

A transmission line has self and mutual impedances are 0.8 and 0 pu respectively. Find the positive, negative and zero sequence impedances respectively?

a)

0.6, 0.8 and 1.2 pu

b)

0.6, 0.6 and 1.2 pu

c)

0.6, 0.6 and 0.6 pu

d)

0.8, 0.8 and 0.8 pu

36.

For symmetrical network, the neutral current is

a)

zero

b)

infinity

c)

maximum

d)

any of the above

37.

The positive, negative and zero sequence impedances of a transmission line are 0.5,0.5 and 1.1 pu respectively. The self (Zs) and mutual (Zm) impedances of the line will be given by

a)

Zs = 0.7 pu, Zm =0.2 pu

b)

Zs = 0.5 pu, Zm =0.6 pu

c)

Zs = 0.6 pu, Zm =0.5 pu

d)

Zs = 0.2 pu, Zm =0.7 pu

38.

If all the sequence voltages at the fault point in a power system are equal, then the fault point is a

a)

LLL

b)

LL

c)

LG

d)

LLG

39.

The zero sequence current of a generator for line to ground fault is j3 pu. Then the current through the neutral during the fault is

a)

j3 pu

b)

j1 pu

c)

j9 pu

d)

j6 pu

40.

Which of the following statement is/are true?Zn

a)

The neutral grounding impedance Zn appears as 3Zn in zero sequence equivalent circuit

b)

The neutral grounding impedance Zn appears as Zn in zero sequence equivalent circuit

c)

both 1 and 2

d)

nether 1 nor 2