wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

EAL unit 4 revision 2

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

Additional protection is applicable to:

a)

HRC fuse

b)

BS 3036 rewireable fuse

c)

RCBO

d)

CB

2.

which of the following would not operate if the line conductor bypasses the load and shorts out against the neutral conductor?

a)

HRC fuse

b)

RCD

c)

RCBO

d)

CB

3.

coordination of fuses during fault or overload conditions is known as:

a)

Diversity

b)

Diverging

c)

Discrimination

d)

Deviation

4.

A circuit breaker has two modes of operation:

a)

overload due to thermal effect, or short circuit due to magnetic trip

b)

overload due to magnetic trip or short circuit due to thermal

c)

overload due to chemical reaction, or short circuit due to magnetic trip

d)

overload due to thermal trip, or short circuit due to chemical reaction

5.

A CB rated at 40A will trip:

a)

only when a short circuit occurs

b)

only when an overload occurs

c)

when an overload, short circuit or earth fault occurs

d)

when 41A flows through it

6.

An RCD rated at 30mA will trip:

a)

when enough current flows to earth

b)

when an overload occurs

c)

when the load reaches 30mA

d)

when a L-N short circuit occurs

7.

which type of CB is associated with commercial applications, especially fluorescent lighting?

a)

type 3

b)

type B

c)

type C

d)

type D

8.

Which devices will detect an imbalance between the line and neutral, overload and all type of overcurrent fault?

a)

RCD

b)

RCBO

c)

CB

d)

BBC

9.

A fuse protects:

a)

the person

b)

the switch

c)

the cable

d)

the load

10.

an RCD protects

a)

the person

b)

the switch

c)

the cable

d)

the load

11.

A value that ensures that a circuit breaker can withstand a fault current is known as:

a)

breaking capacity

b)

rating

c)

thermal constraint

d)

shock protection

12.

the normal ICN value of a domestic CB is:

a)

1KA

b)

6KA

c)

8KA

d)

10KA

13.

the protection provided by insulating live parts is called:

a)

Extraneous protection

b)

Basic protection

c)

Fault protection

d)

Additional protection

14.

Ladder racking is a system for:

a)

allowing access to storage racks

b)

allowing multiple section extension ladders

c)

supporting armoured cables

d)

supporting vertical cable basket systems

15.

An appropriate wiring method for an underground feed to a remote building would be:

a)

metal conduit

b)

trunking and tray

c)

PVC cables

d)

PVC/SWA cables