Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Corrosion Lab Post Test

Total questions: 10

Worksheet time: 3mins

Name
Class
Date
1.

Corrosion occurs on

a)

variable temperature

b)

increasing temperature

c)

constant temperature

d)

decreasing temperature

2.

The use of SHE in real conditions, is not possible, because

a)

it only work on high temperatures

b)

might freeze during operation

c)

not easy to be conducted

d)

yields invalid result

3.

The following statements are the application of a potential series or volta series, except:

a)

Electrode selection on the battery design

b)

selection of sacrificial anode

c)

Anodic reaction selection

d)

selection of Dummy anode

4.

Here are some chemical reactions involving compounds and elements.

(1) HCl + Fe

(2) FeOH2 + Cu

(3) HNO3 + Fe

(4) Al2O3 + Fe

(5) FeCO3 + H2O

Reactions which are not possible in STP conditions are

a)

(1) (2) (3)

b)

(2) (4) (5)

c)

(1) (4) (5)

d)

(1) (2) (4)

5.

Examples of compounds that might be able to corrode Iron are

a)

H2SO4, HNO3, FeCO3, H3PO4

b)

H2SO4, HNO3, H3PO4, HCl

c)

HNO3, HCl, H2CO3, FeS

d)

HCl, HNO3, H2S, FeSO4

6.

Inhibitors which work by reacting with solution is called

a)

Commercial inhibitors

b)

Anodic inhibitors

c)

Cathodic inhibitors

d)

Mixed inhibitors

7.

Inhibitor efficiency shows

a)

Solubility of inhibitors

b)

Effectiveness in protecting metal from corrosion

c)

Effectiveness in protecting solution from corrosion

d)

Values ​​of corrosion rate after inhibitors injected

8.

Here are some causes of increasing corrosion rates after the inhibitors are injected in corrosive media:

(1) evaporation of inhibitors

(2) Inhibitors vanish because they join the flow of corrosive media

(3) Inhibitors vanish because of reaction with corrosive media

(4) Inhibitors vanish because of reaction with metal

(5) Solidification of inhibitors

The correct statement is shown by the number

a)

(4) (5)

b)

(1) (5)

c)

(2) (3)

d)

(1) (2)

9.

Below are the step on Cathodic Protection (CP) design is, except

a)

Wenner Four Pin Testing for soil environment

b)

Selection of sacrificial anode types

c)

Potential surveys in the water environment after installing CP System

d)

The calculation of the area which the structure buried

10.

The anode installed on ICCP and SACP are selected from metal with opposite characteristics, this is because:

a)

The SACP anode must be small, while the anode ICCP must be large

b)

The SACP anode must be consumed by corrosive media, while the anode ICCP only closes the circuit

c)

The SACP anode must be more positive than the structure, while the ICCP anode only closes the circuit

d)

The anode SACP and anode ICCP only close the circuit