1.

Which of the following are classified as a statutory?

a)

Chemicals or substances hazardous to health (COSHH)

b)

Guidance notes

c)

BS7671:2018

d)

Personal protective equipment (PPE)

2.

Which of the following are classified as non statutory?

a)

BS7671:2018

b)

Codes of practice

c)

On-Site Guide

d)

Unite Union Book

3.

What type of diagram shows how a circuit is wired in practice?

a)

Circuit diagram

b)

Wiring diagram

c)

Schematic diagram

d)

Block diagram

4.

What type of diagram shows the sequence of equipment?

a)

Architectural plans

b)

Schematic diagram

c)

Block diagram

d)

Circuit diagram

5.

The length of a road is 380Km If 0.2cm represents 20Km, calculate the length of the road on the map.

a)

190

b)

0.19

c)

19

d)

4

6.

The dimensions of a building are 125m by 60m. If 5mm represents 10m on a scale drawing, calculate the dimensions of the building on the map.

a)

62.5mm by 30mm

b)

25mm by 12mm

c)

62.5mm by 12mm

d)

25mm by 30mm

7.

The number of outlets connected to an A1 ring final circuit is unlimited providing the floor area served does not exceed...

a)

100m2100m^2  

b)

75m275m^2  

c)

50m250m^2  

8.

State the protective device rating for an A3 radial final circuit.

a)

16A

b)

32A

c)

20A

d)

40A

9.

Name one means of heat transference used in space heating.

(a)  

10.

State the two classifications for emergency lighting.

(a)  

11.

What two things are fire alarm circuits designed to protect?

(a)  

12.

Fire alarm systems are normally connected in.

a)

Series

b)

Parallel

13.

Which are diameters of steel conduit?

a)

15mm

b)

20mm

c)

22mm

d)

32mm

14.

What is the colour for a 20A BS3036 fuse?

a)

Green

b)

Blue

c)

Red

d)

Yellow

15.

What is the colour for a 15A BS3036 fuse?

a)

Blue

b)

White

c)

Red

d)

Green

16.

A current resulting from a fault is called a.

(a)  

17.

Which are renewable energy sources of electricity?

a)

Wind

b)

Wave

c)

Gas

d)

Photo - Voltaic

18.

Which are non renewable sources of electricity?

a)

Oil

b)

Nuclear

c)

Gas

d)

Coal

19.

Which earthing system requires an earth rod?

a)

TNS

b)

TNCS

c)

IT

d)

TT

20.

What is the most common earthing arrangement in a domestic dwelling?

a)

TNS

b)

TT

c)

IT

d)

TNCS

21.

Where would you find a IT earthing arrangement?

a)

Spas / Swimming areas

b)

Factories

c)

Hospitals

d)

Domestic Dwellings

22.

What type of electricity 'grids' do we have in the UK?

a)

National Grid

b)

Super Grid

c)

Local Grid

d)

District Network Authority Grid

23.

Which of the following is the symbol for an intermediate light switch?

a)
b)
c)
d)
24.

What is the size of the circuit protective conductor in a 2.5mm22.5mm^2  twin and earth cable?

a)

2.5mm22.5mm^2  

b)

1mm21mm^2  

c)

0.5mm20.5mm^2  

d)

1.5mm21.5mm^2  

25.

A circuit installed to supply a fire panel would be identified as which of the following?

a)

Control Panel

b)

Power & Heating

c)

Alarm & Emergency System

d)

Data Communication

26.

The type of trunking that can be used as a circuit protective conductor is which of the following?

a)

Mini

b)

PVC Dado

c)

Plastic

d)

Steel

27.

Which of the following are types of steel conduit fixing?

a)
b)
c)
d)
28.

Which one of the following symbols represents the rating factor for thermal insulation?

a)

Ca

b)

Cf

c)

Ci

d)

Cc

29.

The insulation material of mineral insulated metal sheathed cables is absorbent; therefore the terminations must be?

a)

Fitted With A Gland

b)

Watertight

c)

Fitted With A Shroud

d)

Correctly Identified

30.

Which one of the following is the value of voltage drop, in millivolts per ampere per metre, for a 4mm24mm^2  multi core thermosetting non armoured cable, intended to supply a single phase circuit?

a)

11 mV/A/m

b)

29 mV/A/m

c)

18 mV/A/m

d)

7.3 mV/A/m