WorksheetsBSE Systems T-Levels
Total questions: 42
Worksheet time: 21mins
A Ring Final Circuit is recommended to encompass a maximum floor space of...
50 m2
100 m2
150 m2
200 m2
Which one of these is NOT a type of cable containment system?
Tray
Conduit
Boxing
Trunking
Which BSE system is capable of heating and cooling a building as well as controlling the humidity of the air?
Air Conditioning
Ventilation
Central Heating
Protection
In which Air Conditioning system is the air conditioned in the main AC unit, before being distributed via ducting?
Lateral Plant
Control Plant
Central Plant
Exterior Plant
Which type of Air Conditioning system is capable of supplying various rooms a different temperature according to demand?
Constant Air Volume (CAV) systems
Variable Air Volume (VAV) systems
A lighting circuit must always have a switch on which part of the circuit?
Neutral
Earth
Line
Load
Gas tightness testing is done using a...
Manometer
Barometer
Hydraulic tester
Gas Flue Analyser
A Let-By test is done on a gas system to ensure...
The gas installation is not leaking
The gas installation operates under complete combustion
The Thermocouple is in good working order
The ECV is not letting by when in the off position
A Thermocouple within a gas appliance carries a current of...
5 mV DC
10 mV DC
5 mV AC
10 mV AC
When talking about domestic gas fires, what does the acronym DFE stand for?
Decorative Fuel Effect
Domestic Fuel Energy
Decommissioned Fire Enclave
Design Fuel Embodiment
What type of Central Heating system is shown here?
S-Plan
S-Plan Plus
Y-Plan
Combination Boiler
In this position, is this valve feeding the Central Heating, or the Hot Water side of the installation?
Central Heating
Hot Water
Both
Neither
What type of Central Heating system is shown here?
S-Plan
S-Plan Plus
Y-Plan
Combination Boiler
Which type of central heating system utilises a manifold and pipework buried in a bed of screed?
Heat Only Boiler
Combi Boiler
Underfloor Heating
Warm Air Heating
In a commercial central heating system, which pipework configuration forces the return to flow away from the boiler to encourage an even distribution of heat and to minimise the need for system balancing?
Two-Pipe
Direct Return
Primary Return
Reverse Return
In large commercial heating systems, how is the risk of no heating or water pressure mitigated?
By installing multiple boilers and pumps to share the demand
By installing multiple Central Plant AC systems
By using Primary pumped and reverse return systems
By encouraging engineers to work late nights to keep an eye on things
To prevent freezing and damage from traffic vibration, a cold water mains service should be buried at a depth of between...
600mm-1200mm
700mm-1300mm
750mm-1350mm
850mm-1450mm
In a direct cold water system, the cold water main feeds the kitchen sink directly.
True
False
In an in-direct cold water system, the cold water main feeds the kitchen sink directly.
True
False
The water undertaker is legally obliged to supply homes with water of which fluid category?
Category 1
Category 2
Category 3
Category 5
Which 2 components replace the open-vent pipe in an un-vented hot water system?
F&E and Heat Pump
PRV and Expanding foam
Expansion Vessel and PRV
Cylinder Thermostat and PRV
According to sanitary spacing guidance, what distance should should be left as free space in front of a basin and a toilet?
400mm
500mm
550mm
600mm
In accordance with BS7671, what cable must be used for fire protection systems?
Twin and Earth
FP200
Heat-Resistant Flex
SWA
Domestic Intruder Alarm systems incorporate what sort of sensor?
PIR (passive infrared)
PUW (potential under wave)
POR (passed original region)
PAR (possible alarm route)
Which part of the refrigeration cycle is being described here- heat is absorbed by the refrigerant to phase change to gas.
Compression
Condensation
Expansion
Evaporation
Which part of the refrigeration cycle is being described here- increases the gas pressure and elevates the heat capacity of the gas.
Compression
Condensation
Expansion
Evaporation
Which hermetically sealed refrigeration component is shown here?
Expansion Valve
Condenser
Compressor
Evaporation Chamber
What is the purpose of a ventilation system?
Provide air for respiration
Preserve the correct level of oxygen in the air
Control moisture content in the air
All of the above
Which of these statements is true of a Centrifugal pump?
The pump is only suitable and will only function correctly under negative pressure
The pressure generated has to be sufficient to overcome the total frictional resistance of the system
The pressure generated by the pump is used to co-generate electricity
The pump can only be used for hydroelectric power generation
Axial fans generate a streamlined flow, otherwise known as a...
Laminate flow
Ladible flow
Laminar flow
Limited flow
Which process do Ground Source Heat Pumps (GSHPs) use to transfer low grade heat into usable high grade temperatures?
The Rainwater Cycle
The Vapour Compression Cycle
The Hydrological Cycle
Ohm's Law
Which type of central heating pipework would be most suitable for a commercial building with expected heavy footfall?
LCS (low carbon steel)
Copper
Polybutylene
Polyethylene
What is the recommended clipping distance for 15mm vertical copper pipe?
1.2 M
1.5 M
1.8 M
2.4 M
In electrical systems, which wire is denoted by blue insulation?
Live
Line
Neutral
Earth
With electrical protection devices, which CPD protects the 'group' of circuits?
MCB
Rewireable Fuse
Cartridge Fuse
RCD
Which one of these is a drawback of installing a Photovoltaic Solar system?
The solar system can produce more energy than needed
The solar cells have a finite lifespan
Solar energy can be transferred from AC to DC via an Inverter
Solar panels produce zero carbon energy
Which electrical earthing arrangement is shown here?
TT
TN-S
TNC-S
No earth
Which electrical earthing arrangement is shown here?
TT
TN-S
TNC-S
No earth
Which electrical earthing arrangement is shown here?
TT
TN-S
TNC-S
No Earth
A central system for managing a building's valves and components that has a specific focus on reducing energy usage can be abbreviated as a...
BMS
BEMS
IoT
BIM
Each individual gas appliance's pressure can be set and maintained by the...
Constant Pressure Governor
Thermocouple
Gas Solenoid Valve
Flow Switch
The output of most alternators is:
2000 V
20,000 V
25,000 V
35,000 V