Worksheetscompatibility part 3
Total questions: 17
Worksheet time: 9mins
TRANSPORTATION
RBCs
temperature of 1-10oC
Ice in plastic bags and placed on top of the units (9 lbs)
shipped in dry ice
space left in the box for movement
TRANSPORTATION
Fresh Frozen Plama
temperature of 1-10oC
Ice in plastic bags and placed on top of the units (9 lbs)
shipped in dry ice
space left in the box for movement
Which statement is incorrect?
Blood must be infused within 4 hours due to risk of bacterial growth
If blood is removed from the Blood Bank, it must be returned within 30 minutes or it cannot be re-issued to the intended recipient nor put back into inventory
Only normal saline (.9%) should be administered with blood
Hypotonic solutions such a
Blood can reach over 10 C and be put back into inventory
Which can be administered with a blood transfusion?
Saline (0.9%)
Hypotonic solution (dextrose)
Ringer’s lactate which contains calcium
all of the above
refrigerators, freezers, platelet incubators, refrigerated centrifuges, heat blocks/water baths must be checked ________
daily, some continuously
every 4 hours
minimum of 5 years
every 24 hours
Records of blood component inspection
Patient’s ABO/Rh, compatibility results
The following after retained for a ______
daily, some continuously
every 4 hours
minimum of 5 years
every 24 hours
Storage Temp.
Red blood cell product
2-6°C
-18°C
20-24 °C
-70°C
Storage Temp.
Plasma containing product
2-6°C
-18°C
20-24 °C
-70°C
Storage Temp.
Platelet products
2-6°C
-18°C
20-24 °C
-70°C
Storage Temp.
Frozen RBC
2-6°C
-18°C
20-24 °C
-70°C
________ is the most likely place a blood bank refrigerator is allowed (outside of Laboratory Transfusion Service Center)
nursing refrigerator
surgery
ER
all of the above
Automated cell washers must be checked for accuracy as to speed.
speed is verified with a ______
tachometer
NIST certified stopwatch
speedometer
all of the above
states a program shall be established that ensures reagents, equipment, and methods perform as expected
AABB
CAP & JC
Manufacturer’s Instructions
Site laboratory procedure
require QC daily on reagents
AABB
CAP & JC
Manufacturer’s Instructions
Site laboratory procedure
state the QC guidelines for their product
AABB
CAP & JC
Manufacturer’s Instructions
Site laboratory procedure
Refrigerators, freezers, platelet incubators used for storage of Blood Products if not monitored continuously must be checked________
daily, some continuously
every 4 hours
minimum of 5 years
forever
Donor’s identification information, medical history, physical exam, and interpretations for disease markers
Blood and components from outside sources, including the donor unit number and name of the collecting facility are kept ______
daily, some continuously
every 4 hours
minimum of 5 years
forever
