NEW
Font size
Worksheets:) National Building Code of The Philippines
Total questions: 25
Worksheet time: 14mins
What is the title of Rule 7 in NBC?
Protection of Pedestrians during Construction or Demolition
Fire Resistive Requirements in Construction
Light and Ventilation
Classification and General Requirements of all Bldgs. by use or Occupancy
___ is the required open space left between the outermost face of the bldg/structure and the property lines e.g: Front, Rearand Left side.
Setback
Yard
Abutments
Courts
Maximum Allowable PSO (percentage site occupany) for Maximum R-3 with firewall
70
80
60
50
____ are portions of the Total Lot Area (TLA) not occupied by the Maximum Allowable PSO.
USA (Unpaved Surface Area)
PSO (Percentage Site Occupancy)
TOSL (Total Open Space within Lot)
ISA (Impervious Surface Area)
Eaves, canopies,awnings (or media agua) over required windows shall not be less than ___mm from the side and rear property lines.
650
750
600
700
All pipes materials to be used in bldgs/structures shall conform to the standarad specifications of the Bureau of Product Standards (BPS) of the _____
DTI
NBC
OBO
SEC
Maximum Allowable PSO (percentage site occupany) for Commercial C-3 WITHOUT firewall is ?
90
85
75
80
Maximum Allowable PSO (percentage site occupany) for Institutional with firewall
60
50
55
70
The cemetery shall be totally enclosed by a perimeter fence/wall of strong material, and all gates shall be provided with strong door and lock. Perimeter wall shall not exceed ___ meters in height.
3.5m
2.5m
4.0m
3.0m
Stairs shall be at least ___ millimeters in clear width, with a rise of 200 millimeters and a minimum run of 200 millimeters.
700
750
650
600
Minimum Number of Exits for Apartments that has more than 10 Occupancies
1
2
3
4
If only two (2) exits are required they shall be placed a distance apart to not less than ___of the perimeter of the area served measured in a straight line bet. exits.
1/2
1/3
1/6
1/5
Every corridor or exit balcony shall not be less than ____ meters in width.
1.0m
1.1m
1.2m
1.5m
For wards and dormitories of institutional buildings – not less than ___ cubic meter of air per minute shall be supplied for each person accommodated.
0.20
0.30
0.40
0.45
Door Leaf Width. No leaf of an exit door shall exceed ___meters in width
1.00m
1.10m
1.20m
1.50m
Distance Between Landings. There shall be not more than ___ meters vertical distance between landings.
3.50m
3.60m
2.40m
2.50m
Minimum air space for Workshops, Factories, and Offices is ___ cubic meters of air space per person
1.00
10.00
12.00
14.00
_____ is a nonstructural facing of brick, concrete, tile, metal, plastic, glass, or other similar approved materials attached to a backing or structural components of the building for the purpose of ornamentation, protection, or enclosure that may be adhered, integrated, or anchored either on the interior or exterior of the building or structure.
Enclosure of Vertical Openings
Veneer
Anchors
Support
Changes in Elevation. Except in Group A Occupancies, changes in floor elevations of less than ___ millimeters along any exit serving a tributary occupant load of 10 or more shall be by means of ramps:
250
300
350
400
Each mezzanine floor used for other than storage purposes, if greater in area than 185 square meters or more than 18.00 meters in any dimension, shall have at least ___ stairways to an adjacent floor.
FOUR
THREE
TWO
ONE
The required width of corridors and exterior exit balconies shall be unobstructed. Except, that trim handrails, and doors when fully opened shall not reduce the required width by more than ___ millimeters.
200
250
100
150
Circular Stairways. Circular stairs may be used as an exit provided the minimum width of run is not less than ___ millimeters
250
200
150
100
Every required stairway shall have a headroom clearance of not less than ___ meters. Such clearance shall be established by measuring vertically from a plane parallel and tangent to the stairway tread nosing to the soffit above all points.
2.00m
2.40m
3.00m
1.80m
Title of Chapter Six in NBCP?
Fire Resistive Requirements in Construction
Requirements for Fire Zones
Fire-Resistive Regulations
Fire Zones Defined
Regular plate, sheet, or patterned glass in jalousies and louvered windows shall not be thinner than 5.6 millimeters minimal and not longer than ___ meters.
1.00m
1.20m
1.60m
1.40m
