wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Standard Codes

Total questions: 30

Worksheet time: 15mins

Name
Class
Date
1.

Minimum exit door width.

a)

0.60m

b)

0.70m

c)

0.71m

d)

0.80m

2.

Travel distance to an exit without fire sprinkler system.

a)

45.00m

b)

46.00m

c)

60.00m

d)

61.00m

3.

Travel distance to an exit with fire sprinkler system.

a)

45.00m

b)

46.00m

c)

60.00m

d)

61.00m

4.

Number of exits for place of assembly for 600-1000 occupants.

a)

2

b)

3

c)

4

d)

5

5.

Number of exits for place of assembly for 1000 occupants

a)

2

b)

3

c)

4

d)

5

6.

Maximum number of seats in a row in between aisles.

a)

7

b)

10

c)

14

d)

20

7.

Maximum number of seats in a row opening on to an aisle at one side.

a)

7

b)

10

c)

14

d)

20

8.

Minimum floor to ceiling height of a habitable space.

a)

2.10m

b)

2.30m

c)

2.40m

d)

2.70m

9.

Minimum dimension of landings in direction of travel for class A & B stairs.

a)

1.10m

b)

1.12m

c)

1.20m

d)

1.00m

10.

Minimum number of risers in any one (1) flight of stairs.

a)

3

b)

4

c)

5

d)

10

11.

Minimum height of a guard rail.

a)

0.90m

b)

0.91m

c)

0.85m

d)

1.05m

12.

Maximum height of a guard rail.

a)

1.00m

b)

1.05m

c)

1.06m

d)

1.10m

13.

Minimum width of any balcony or bridge.

a)

1.00m

b)

1.10m

c)

1.12m

d)

1.15m

14.

Minimum width of a class A ramp.

a)

1.00m

b)

1.10m

c)

1.12m

d)

1.15m

15.

Minimum height of buildings requiring automatic sprinkler protection.

a)

12m

b)

15m

c)

21m

d)

30m

16.

Standard width of a seat without dividing arms for places of assembly.

a)

1.00m

b)

0.80m

c)

0.65m

d)

0.60m

17.

Minimum number of exit for an Institutional type of structure.

a)

2

b)

3

c)

4

d)

6

18.

Minimum width of an aisle for an educational use building.

a)

1.50m

b)

1.12m

c)

1.20m

d)

1.80m

19.

Minimum width of an aisle for business use structure.

a)

1.50m

b)

1.12m

c)

1.20m

d)

1.80m

20.

Minimum width of an aisle for an industrial building.

a)

1.50m

b)

1.12m

c)

1.20m

d)

1.80m

21.

Occupant load per person for laboratories.

a)

1.40 sqm

b)

4.60sqm

c)

18.60sqm

d)

28.00sqm

22.

Occupant load per person for Institutional Sleeping Department

a)

1.80sqm

b)

11.00sqm

c)

22.00sqm

d)

18.60sqm

23.

Occupant load per person for Institutional Treatment Departments.

a)

1.80sqm

b)

11.00sqm

c)

22.00sqm

d)

18.60sqm

24.

Occupant load per person for Auditorium.

a)

0.65sqm

b)

1.40sqm

c)

1.80sqm

d)

2.80sqm

25.

Occupant load per person for Dwellings.

a)

9.30sqm

b)

18.60sqm

c)

28.00sqm

d)

7.40sqm

26.

Minimum width of an aisle for hospitals or nursing homes.

a)

1.80sqm

b)

1.96sqm

c)

2.12sqm

d)

2.44sqm

27.

Minimum width of an aisle for custodial care institutions.

a)

1.80sqm

b)

1.83sqm

c)

1.90sqm

d)

2.01sqm

28.

Minimum travel distance from any individual room subject to occupancy 

by not more 6 persons.

a)

9.60m

b)

15.00m

c)

21.00m

d)

25.00m

29.

Minimum dimension of a kitchen.

a)

1.20m

b)

1.50m

c)

1.80m

d)

2.10m

30.

Minimum headroom clearance for a mezzanine.

a)

1.20m

b)

1.50m

c)

1.80m

d)

2.10m