AIR CONDITIONING SYSTEMS
IN BUILDINGS
UNITARY SYSTEM
SPLIT – TYPE SYSTEM
CENTRALIZED SYSTEM
Air conditioning – is the process of treating air so
as to control simultaneously its
1. Temperature
2. Humidity
3. Cleanliness and
4. Distribution
to meet the requirements of the conditioned
space.
Article 8.1 PSME Code, 1993
Article 8.1 PSME Code, 1994
Article 8.1 PSME Code, 1995
Article 8.1 PSME Code, 1996
Average Normal
Temperature:
27.39
deg. centigrade
27.40
deg. centigrade
27.49
deg. centigrade
27.50
deg. centigrade
Average Max.
Temperature:
30
deg. centigrade
31
deg. centigrade
32
deg. centigrade
33
deg. centigrade
Average Min.
Temperature:
24.06 % deg.
centigrade
24.07 % deg.
centigrade
24.08 % deg.
centigrade
24.09 % deg.
centigrade
Relative
Humidity:
76.5 %
Average
76.6 %
Average
76.7 %
Average
76.8 %
Average
Temperature @ 25 Degrees Centigrade at 60%
Relative Humidity
Average Max.
Temperature:
Comfort Limit
Average Min.
Temperature:
Average Normal
Temperature:
transports the refrigerant
at the required pressure through the air
conditioning system.
COMPRESSOR
CONDENSER
FILTER DRIER
EVAPORATOR
works in the opposite way to the Evaporator.
The refrigerant gives up its heat generated by the Compressor by
passing cold air across its fins and tubes by ram air or by an extra fan.
The end result of this change is that the refrigerant is now a high
pressure liquid and is forced out to the Receiver Drier through the
liquid line
COMPRESSOR
CONDENSER
EVAPORATOR
EXPANSION DEVICE
this item can be called a Receiver Drier or an
Accumulator.
is responsible for removing moisture from
the air conditioning system by means of a bag of
desiccant which absorbs small quantities of
moisture.
COMPRESSOR
CONDENSER
FILTER DRIER
EXPANSION DEVICE
have an inlet and an outlet which separates the high side of the
system from the low side. A small restriction in the valve allows only a
small amount of refrigerant to pass through it into the Evaporator, the amount of refrigerant passing through the valve depends on the Evaporator
temperature.
COMPRESSOR
CONDENSER
FILTER DRIER
EXPANSION DEVICE
absorbs the heat passing over its tubes and fins and as a result the air is cooled. Remember that heat is being removed from the warm
air and cold air is not being created. The compressor, on its suction side, removes the low pressure vapor from the
Evaporator and the cycle starts all over again
COMPRESSOR
CONDENSER
EVAPORATOR
EXPANSION DEVICE
is a self-contained aircon unit
cabinet. This is commonly known as
window type air conditioner or
“through the wall” air
conditioner
Unitary Aircon
Split – Type Aircon System
Centralized Aircon System
Air Handling Unit (AHU)
Advantages of Unitary
Aircon:
Control is in the hands
of the user making
every room as an
individual zone.
Easy to remove for
servicing & replaced
with another unit
Space saving
Disadvantages of
Unitary Aircon:
Shorter life span
Protruding units to
exterior present
challenges or
problems in architect’s
design.
the bottom potion of the air-condition unit should be ___ above the floor level
.75-1.50m
.80-1.60m
.85-1.70m
.90-2.00m
min. clearance of air-condition unit to fence or wall:
.5m
.6m
.7m
.8
min clearance of air-condition unit to roof:
100mm
150mm
200mm
250mm
500 BTUh can cool
an area of __
square meter
1
2
3
4
1 hp can cool an
area of ___
square meters
18-20
16-17
15-16
20-24
is an aircon system consisting of two
separate equipment:
Aircon Condensing Unit (ACU or ACCU)
The Fan Coil Unit (FCU)
Unitary Aircon
Split – Type Aircon System
Centralized Aircon System
contains the
compressor and is placed outdoors for heat rejection.
Aircon Condensing Unit (ACU or ACCU)
Fan Coil Unit (FCU)
Air Handling Unit (AHU)
contains the evaporator and is found
indoors as part of the cooling and air handling assembly.
Aircon Condensing Unit (ACU or ACCU)
Fan Coil Unit (FCU)
Air Handling Unit (AHU)
Types of Split – Type Aircon as to Mounting
Range of cooling load (sq.m. / tr):
office building
15 to 25
21 to 25
8 to 15
23 to 32
Range of cooling load (sq.m. / tr):
classrooms
15 to 25
21 to 25
8 to 15
23 to 32
Range of cooling load (sq.m. / tr):
hotels
23 to 32
20 to 25
25 to 30
15 to 25
Range of cooling load (sq.m. / tr):
Apartment
23 to 32
20 to 23
40 to 55
20 to 25
usually has the
following elements:
1.The Air Handling Unit (AHU)
2. Air Distribution System
3.A method of cooling, either a mechanical plant
(condensing unit) or an absorption machine (cooling tower)
4. Control Equipment
Unitary Aircon
Split – Type Aircon System
Centralized Aircon System
Air Handling Unit (AHU)
consisting of fans and ducts that
bring the conditioned air to the rooms and back
to the air conditioner for re-cooling.
Air Distribution System
Air Handling Unit (AHU)
Aircon Condensing Unit (ACU or ACCU)
The Fan Coil Unit (FCU)
is a hoisting and
lowering mechanism equipped
with a car or plaÇorm which
moves in guides in a vertical
direction, and which serves
two or more flfloors of a building
or structure.
elevator
escalator
walkalator
dumbwaiter
Elevator used for tall buildings. It is DC motor operated
Electric Elevator
Hydraulic Elevator
Machine-Room-less Elevator (MRL)
Geared and Gearless Traction Elevators
It is plunger(antennaeic/movable rod) operated
first developed by Dover (now Thyssen Krupp)
economical for 2-7 floors uses piston (plunger) to push elevator up
some soil contamination risk due to use
of oil in piston shas
Electric Elevator
Hydraulic Elevator
Machine-Room-less-Elevator
(MRL)
Geared and Gearless Traction Elevators
is made up of a motor that has a gearbox attached to it. The main function of the gears is to power the wheel that moves the ropes. This type of elevator can travel up to speeds of up to 500 feet per minute. The maximum distance it can travel is 250 feet.
Electric Elevator
Hydraulic Elevator
Machine-Room-Less Elevator
(MRL)
Geared Traction Elevator
have the wheel attached directly to the motor. Gear-less traction elevators are capable of speeds up to 2,000 feet per minute and they have a maximum travel distance of around 2,000 feet so they are the only choice for high-rise applications.
Electric Elevator
Hydraulic Elevator
Geared Traction Elevator
Gearless Traction Elevator
are traction elevators that do not have a dedicated machine room above the elevator shaft. The machine sits in the override space and is accessed from the top of the elevator cab when maintenance or repairs are required.
Electric Elevator
Hydraulic Elevator
Machine-Room-Less Elevator (MRL)
Geared and Gearless Traction Elevators
operate based on the natural laws of physics. Constructed with polycarbonate and aluminum materials, this lift system is basically a tube in a sealed vacuum. The air beneath and above the elevator car is what facilitates movement
Vacuum(Pneumatic) Home Elevator
Electric Elevator
Hydraulic Elevator
Machine-Room-Less Elevator (MRL)
An external elevator, especially a temporary one up the side of a building that is under construction or repair.
Buck hoist Elevator
Passenger Elevator
Freight Elevator
Handicap Elevator
are designed to move goods and materials throughout a building. Compared to passenger elevators, it travel at slower speeds, can carry much heavier loads and are designed to withstand tougher working conditions.
Buck hoist Elevator
Passenger Elevator
Freight Elevator
handicap Eelvator
an elevator used primarily to carry persons other than the operator and persons necessary for loading and unloading.
Passenger Elevator
Buck Hoist Elevator
Freight Elevator
Handicap Elevator
stops car and (if required)
counterweight in case of emergency
by actuating the Safety.
Governor
Safety
Limit Switches
Buffer
is a device incorporated in the
bottom beam of the car frame and
counterweight. Exerts retarding force
in case of overspeed, by gripping the
guide rails
Governor
Safety
Limit Switches
Counterweight
– are automatic devices
which stop the car within the
overtravel, independently of the
operating device
Governor
Safety
Limit Switches
Counterweight
balances the weight
of the car, and usually equals weight of
car plus 40% of car capacity.
Safety
Limit Switches
Counterweight
Buffer
is a device that absorbs the
impact of car or counterweight at the
lower limits of travel.
Governor
Limit Switches
Counterweight
Buffer
Typical capacity for passenger elevator
1000-1500lbs
2000-5000lbs
3000-6000lbs
4000-8000lbs
use geared AC or DC motors with worm
gears for mid--rise buildings (up to about
1000 feet) high-speed gearless have drive shafts
attached directly to the motor; use more expensive "induction motors."
use counterweights, typically set at DL +
40%-50% of LL capacity
Electric Elevator
Hydraulic Elevator
Traction Elevator
Vacuum (Pneumatic Elevator)
are small lift installed in kitchens for
transferring cooked hot food, dirty utensils, raw materials,
etc. to various pantries at all floors in multi-storied hotels,
large households, marriage halls, restaurants, etc
Dumbwaiter
Walkalator
Escalator
Elevator
is a moving staircase in which
the steps move as a unit upward or downward
at an incline of about 30 degrees. They are
electrically powered, driven by chain and
sprocket, and held in proper place by two
track
Dumbwaiter
Walkalator
Escalator
Elevator
The longest single-span uninterrupted
escalator in Europe is in the ___________
; it is 413-feet (126-m) long,
and takes nearly 3 minutes to ride.
Moscow Metro
Metropolitan Terminal
Pacific Metro
patented the moving
stairs in 1892 and, four years later,
created a 6--foot escalator 'ride' on
Coney Island in New York City
Jesse Reno
Jesse Seno
Jesse Robredo
Jesse Jay
In March 23, 1857 his first elevator was installed
at 488 Broadway in New York.
Elisha Otis
Elisha Valdez
Elisha Ramsey
Elisha Day
Identify A
handrail drive assembly
electric motor
handrail
top sprocket assembly
Identify B
handrail drive assembly
electric motor
handrail
steps
Identify C
Handrail Drive Assembly
Electric Motor
Handrail
steps
Identify E
Handrail Drive assembly
Electric Motor
Handrail
Top sprocket assembly
Identify D
Handrail
steps
top sprocket assembly
bottom sprocket assembly
Identify F
steps
rail guide
handrail drive assembly
electric motor
Identify G
Steps
step rollers
rail guide
handrail drive assembly
Identify H
handrail drive assembly
rail guide
step roller
step chains
Identify I
handrail guide
step chains
steps
bottom sprocket assembly
A further step in the development of horizontal
and vertical transportation in the extension of the principal
lanes of circulation or transportation is the
continuous moving passenger conveyor or belt.
moving walks
escalator
dumbwaiter
elevator
The conveyor operates at speeds of either __meters or
___ meters per minute, with the latter meter per minute being the maximum.
27-36m
28-37m
29-38m
30-39m
The maximum
recommended incline is __
degrees.
11
12
13
14
Width of escalator with:
Speed in meter/minute: 36 m/min
Speed in feet/ Minute: 120 s/min
Capacity in persons/hour: 10,000
Minimum Landing area: 1.12 m²
800
1200
1250
900
Width of escalator with:
Speed in meter/minute: 27 m/min
Speed in feet/ Minute: 90 s/min
Capacity in persons/hour: 5,000
Minimum Landing area: 0.75 m²
800
1200
900
1250
is installed to an external wall of
your house, and enables the air inside to exit straight through the fan itself.
wall mounted exhaust fan
exterior exhaust fan
ceiling mounted exhaust fan
kitchen exhaust fan
are particularly suited to those who
do not want any noise issues, since in this case any noise emitted from the fan would
be outside of the house.
Exterior Exhaust Fans
wall mounted Exhaust Fans
ceiling mounted Exhaust Fans
bathroom Exhaust Fans
These are mounted to the ceiling of a room, and they remove the air inside
through a hole in the ceiling. As such, more often than not a ceiling mounted fan makes
use of a hole in a building’s attic.
Exterior Exhaust Fans
wall mounted Exhaust Fans
ceiling mounted Exhaust Fans
In-line Exhaust Fans
are an excellent way of removing the
unavoidable smells which are inherent in any kitchen. They are also perfectly suited to
lessen the moisture level of your kitchen.
Exterior Exhaust Fans
kitchen Exhaust Fans
in-line Exhaust Fans
ceiling mounted Exhaust Fans
are usually smaller and more affordable than any other kind of exhaust
fan on the market. ensure
that the moisture resulting from washing will be easily eliminated
Exterior Exhaust Fans
bathroom Exhaust Fans
kitchen Exhaust Fans
wall mounted Exhaust Fans
These fans are mounted in between the ducting, so
that the bad air is expelled through the ducts.
Exterior Exhaust Fans
bathroom Exhaust Fans
kitchen Exhaust Fans
in-line Exhaust Fans