WorksheetsL3 AP Cold water P2
Total questions: 17
Worksheet time: 9mins
These type of filters work under pressure to remove most of the dissolved mineral content by passing the water through a very fine membrane
Activated carbon filter
Ion exchange
Sediment filter
Reverse osmosis
Used to reduce limescale formation and other metal-ion contaminants such as lead. It takes the form of tiny granules that work by replacing the mineral or contaminant ions with hydrogen ions
Activated carbon filter
Ion exchange
Sediment filter
Reverse osmosis
Used to reduce taste and odour such as chlorine. The carbon filter has a large surface area that attracts and absorbs organic substances from the water. The carbon is usually in powder, granular or block form
Activated carbon filter
Ion exchange
Sediment filter
Reverse osmosis
A cold water system were all the outlets are from the mains is know as?
Direct
Indirect
Basic
One pipe
A cold water system were most of the outlets are from a cold water cistern is know as?
Direct
Indirect
Basic
One pipe
On a indirect system, what outlet MUST be directly of the mains?
Basin
Wc
Shower
Sink
The min size for a water main is?
15 mm
22 mm
28 mm
10 mm
Due to a greater demand on the cistern, as compared to a direct system, the indirect storage system requires a cold water storage cistern for cold only with a minimum capacity of?
150 Litres
200 Litres
230 Litres
300 Litres
Fluid category 1 represents:
A serious health risk
A significant health risk
A slight health risk
No health risk
Which one of the following back flow
prevention devices must be
installed on a supply to a hose union bib tap, according to the Water Regulations?
AUK 2 air gap
Single check valve
Fullway gate vale
A double check valve
The Water Regulations state that a mixer tap which allows the hot and cold water to mix in the body of the tap with unbalanced pressures must have:
.
Double check valve on both hot and cold supplies
Single check valve of both hot and cold supplies
AUK 3 air gap.
AUK 2 air gap
If a hand basin has submerged
taps, which one of the following back flow prevention devices does the
Water Regulations say must be
installed?
Double check valve
AUK 3 air gap.
Overflow
Single check valve
What air gap is required for a wash hand basin
AUK 2 air gap
AUK 3 air gap
AG air gap
AUK 1 air gap
A double check valve is used to protect category 1 water (wholesome water) from what other category of water
Category 5
Category 4
Category 2
Category 3
What one of these is classed as category 4 water
Fluids representing a severe health risk, containing pathogenic organisms, radioactive, faecal
Fluids representing a significant health risk, containing toxic substances
Fluids representing a slight health risk and are not suitable for drinking
Water that would be classed as Cat 1 except for colour, odour, appearance or temperature
The water regulations state that a mixer tap that allows the hot and cold water to mix in the body of the tap with unbalanced pressures must have
Double check valve on both hot and cold supplies
Single check valve on both hot and cold supplies
AUK 2 air gap
AUK 3 air gap
Due to a greater demand on the cistern, as compared to a direct system, the indirect storage system requires a cold water storage cistern for Hot and cold with a minimum capacity of?
150 Litres
200 Litres
230 Litres
300 Litres