NEW
Font size
WorksheetsBLDG. Laws
Total questions: 40
Worksheet time: 21mins
In BP 344, elevator should be located not more than _____ from the entrance.
25 Meters
30 Meters
40 Meters
50 Meters
The minimum dimension of the elevator shaft should be_____, in accordance to BP 344.
1.10 M x 1.40 M
1.30 M x 1.60 M
1.50 M x 1.80 M
1.60 M x 1.80 M
BP 344: Between the front end of parked cars, a walkway from accessible spaces of ____ clear width should be provided.
1.00 m
1.20 m
1.50 m
1.80 m
BP 344: Accessible public toilet shall have a min. area of _____.
3.06 sq.m
3.60 sq.m
1.7 ft x 1.8 ft
1.6 m x 1.8 m
BP 344: In order to aid visually impaired persons to easily determine whether the washroom is for women or men, the signage for men's washroom door shall be ____; while for women shall be _____.
Circle, Equilateral Triangle
Circle, Heart
Square, Equilateral Triangle
Equilateral Triangle, Circle
BP 344: Handrail shall be installed @ ___ for protection at great heights (stairs balcony and floors).
0.70 & 0.90 m
0.80 & 1.00 m
1.00 to 1.06 m
1.20 to 1.25
BP 344 : Handrails attached to walls should have a clearance of not less than ___ from the wall.
40 mm
0.50 m
50 mm
40 cm
How long is the extension of the handrail should be provided at the start and end of ramps and stairs?
0.20 m
0.30 m
0.45 m
0.50 m
BP 344: What is the Magna Carta for Disabled Persons?
RA 7272
RA 7277
RA 2722
RA 7273
BP 344: What is the height of manual switches above the floor?
0.8 m - 0.9 m
1.0 m - 1.1 m
1.2 m - 1.3 m
0.9 m - 1.0 m
PD 1096: What is the unit area per occupant ( in sq.m) for Dwellings?
7.00
12.00
14.00
28.00
PD 1096 : RULE VI of NBCP is about _____.
Requirements of Fire Zones
Types of Construction
Sanitation
Fire-Resistive Requirements in Constuction
PD 1096: What is the minimum width of easements per side of waterways in urban areas?
20.00 m
15.00 m
3.00 m
5.00 m
PD 1096: What is the minimum size of an articulated truck parking/ loading slot?
3.00 m x 18.00m
3.60 m x 12.00 m
3.00 m x 12.00 m
3.60 m x 18.00 m
PD 1096: What's the minimum dimension for a jeepney or shuttle parking/ loading slot?
3.00 m x 9.00 m
3.00 m x 12.00 m
3. 00 m x 15.00 m
3.10 m x 9.00 m
PD 1096:
The minimum size for a standard truck or bus parking/ loading slot is _____.
3.60 m x 12.00 m
3.60 m x 15.00 m
3.60 m x 18.00 m
3.50 m x 18.00 m
PD 1096: What is the maximum height of dumbwaiters?
1.00 m
1.20 m
1.50 m
1.80 m
PD 1096: It refers to an unoccupied space between the faces of the bldg. lines and a yard or another court, free, open, and unobstructed from the ground upward
Setback
Open Court
Open Space
Court
What is the maximum amount to be paid for the PTR annually?
P100.00
P250.00
P300.00
P500.00
PD 1096: What is the allowable projection of signs into public alleys below a height of 3.00 m?
0.25 m
0.20 m
0.30 m
Projections are NOT allowed
PD 1096:
What is the relative humidity used for comfortable cooling according to NBCP?
30% - 50%
40% - 60%
50% - 60%
60% - 70%
PD 1096: Basic Residential-2 maximum height is _____.
9.00m
10.00m
12.00m
15.00m
PD 1096: Maximum Residential-2 maximum height is ____.
9.00 m
10.00 m
15.00 m
18.00 m
PD 1096: Commercial -1 maximum height is _____.
10.00 m
12.00 m
15.00 m
18.00m
PD 1096:
Institutional Occupancy maximum height is _____.
10.00 m
15.00 m
21.00 m
18.00 m
PD 1096: Tombs and Mausoleums belong to what group of occupancy?
Group E
Group G
Group H
Group J
PD 1096: Woodworking establishments, paint shops, and spray printing rooms belong to what group of occupancy?
Group E
Group F
Group G
Group J
PD 1096: Which occupancy do Church Rectories belong to?
Residential (A-1)
Institutional (H-2)
Assembly(I-1)
Institutional
(H-3)
PD 1096: Which occupancy do Parks and Playgrounds belong to?
Residential (A-1)
Recreational (H-1)
Recreational (H-2)
Institutional
(D-1)
PD 1096: The construction of sheds, outhouses, greenhouses, children's playhouses, aviaries, poultry houses, and the like, not exceeding ____ sq. m in total area shall not require a bldg permit.
4.0sqm
6.0sq.m
10.0sq.m
14.0sq.m
RA 9514: What is the min. stair width for new buildings with less than 2000 occupants?
0.915m
1.10m
1.12m
1.22m
RA 9514: What is the min. stair width for new buildings with more than 2000 occupants?
1.2 m
1.12 m
1.42 m
1.52 m
RA 9514: What is the min. stair width for existing buildings?
915 mm
1120 mm
1420 mm
1520 mm
RA 9514: The min. clear width of the door is ____ and max. clear width is up to ____
0.70m - 1.20 m
0.8m - 1.20 m
0.71 m - 1.22 m
0.82 m- 1.22 m
RA 9514: Releasing device should not be less than 2/3 of door width and placed at ____ above the floor.
0.76 m - 1.12 m
0.80 m - 1.20 m
0.70 m -1.10 m
0.86 m - 1.22 m
BP 957: Minimum width for motorcourts shall be ___.
2.00 m
3.00 m
5.00 m
6.00 m
PD 957: For subdivision development having 1 ha. or more, parks and playgrounds allocated should be not less than ____.
50 sq.m
100 sq.m
120 sq.m
150 sq.m
PD 957: What is the minimum width of the Major Road allocated for 2.5- 5 ha. Open Market Subdivision?
8 m
10 m
12 m
15 m
PD 957: What is the minimum width of the Major Road allocated for 2.5- 5 ha. Medium Cost Subdivision?
8 m
10 m
12 m
15
PD 957: What is the minimum area allocated for Open Market Duplex Housing?
120 sq.m
100 sq.m
98 sq.m
96 sq.m