Font size
WorksheetsFire Insp & Code Enf Ch 6
Total questions: 132
Worksheet time: 11hrs 51mins
_____ - Wall with a specified degree of fire resistance that is designed to prevent the spread of fire within a structure or between adjacent structures.
Fire Wall
Fire Stop
Thermal Barrier
Fire Damper
_____ - (1) Portion of the exterior walls of a building that extends above the roof. (2) Any required fire walls surrounding or dividing a roof or surrounding roof openings such as light/ventilation shafts.
Parapet
Fire Wall
Opening Protection
Curtain Wall
_____ - A device installed over an opening or within a wall assembly to protect it against smoke, flame, and heated gases.
Opening Protective
Fire Wall
Curtain Wall
Return-Air Plenum
Within a building, interior walls subdivide areas for such purposes as: (select all that apply)
Security
Privacy
Separation of Occupancies
Bearing Structural Loads
A _____ is a fire-resistance-rated wall with protected openings that restricts the spread of fire.
Fire Wall
Fire Protection Wall
Party Wall
Fire Partition
Fire walls are typically constructed of _____ although other fire-resistive materials like concrete or gypsum board can be used in a fire-rated assembly.
Masonry
Wood
Steel
Glazing
Fire walls can be constructed with fire-resistance ratings of _____ hour(s).
2 or more
1 to 2
1 or less
1.5
Building codes typically allow a reduction in a fire wall's fire-resistance rating if the building is equipped with a(an) _____.
automatic sprinkler system
automatic fire detection system
sufficient degree of insulation
fire resistant building material (i.e. Type I or Type II construction)
Fire walls may extend beyond walls and roofs to prevent the radiant heat of flames from igniting adjacent surfaces. This extension is accomplished by continuing the fire wall through the roof in the form of a(an):
Parapet
Opening Protective
Curtain Wall
Wall Extension
All openings in fire walls must be protected by approved opening protectives, such as: (select all that apply)
Fire Shutters
Fire-Rated Doors
Parapet
Interstitial Space
A _____ is a wall that is located on a lot line between two buildings and is common to both buildings.
Party Wall
Fire Wall
Curtain Wall
Enclosure Wall
_____ - Nonload-bearing exterior wall attached to the outside of a building.
Curtain Wall
Party Wall
Parapet
Enclosure or Shaft Wall
Fire partitions and fire barriers are interior walls that subdivide a floor or area of a building _____ qualify as fire walls.
but do not
that do
that sometimes
that rarely
Fire partitions are typically _____ structures.
1-hour-rated
2-hour-rated
load-bearing
nonload-bearing
Enclosure walls are designed to block:
the vertical spread of fire through a building.
the horizontal spread of fire through a building.
entrance to restricted areas of a building.
ventilation and smoke circulation.
In stairwells, enclosure walls are designed to protect:
a means of egress.
a means of ingress.
building occupants.
the owner's interests.
As in the case of fire barriers, the use of fire-rated glazing provides a fire barrier while permitting _____, which can enhance security.
observation of the stair enclosure
ventilation
radiant heat to escape
the use of a lower fire-protection-rating in surrounding materials
When a building is constructed using a structural frame, the exterior wall functions only to enclose the building and is known as a _____ (or sometimes as cladding).
Curtain Wall
Fire Wall
Parapet
Opening Protective
The design function of a curtain wall is to separate:
the interior environment from the exterior environment.
the exterior environment from the interior environment.
occupants from a fire.
a fire from ventilation.
Roof coverings provide the _____ for the roof system.
water-resistant barrier
fire-resistant barrier
structural support
insulation
What are the classes of floor finishes? (select all that apply) See Page 222.
Rotating
Which of the following are fire and life safety aspects of building services and subsystems? (select all that apply) Page 229
Grease ducts
Model codes require refrigeration machinery rooms to be equipped with which two systems? (select all that apply) Page 232
What are the two most common types of cooling methods for transformers? (select all that apply) Page 234
Which of the following should be regularly maintenanced on a HVAC system? (select all that apply) Page 229
Air heating and cooling systems
Bolts
Which type of window swings outward at the top or bottom and slides upward or downward in grooves? Page 215
What are examples of Fire-Retardant coatings? (select all that apply) Page 228
Codes may require the installation of ___ or ___ to protect duct penetrations through fire-rated assemblies. (select all that apply) Page 230
At one time, the flammability of floor coverings was considered insignificant in overall building safety. Because:
the heat from a fire rises, it was assumed that anything located at floor level would be at the coolest part of the room.
fire burns vertically upwards much more quickly than horizontally or vertically downwards.
any fire not starting at floor level will be slower to reach the floor than any other part of the room.
floors are typically designed using inherently fire-resistive materials, something which has changed due to modern fabrication methods.
