1.

Otherwise known as the Fire Code of the Philippines of 2008

a)

RA 9266

b)

RA 13150

c)

RA 9614

d)

RA 9514

e)

None of the Above

2.

The duly designated head of the City or Municipal Fire Station including those designated as “Officer-in-Charge” or in an “Acting” capacity.

a)

Fire Marshall

b)

City/Municipal Fire Marshall

c)

Fire Superintendent

d)

Fire Chief

e)

None of the Above

3.

Fires involving ordinary combustible materials such as wood, cloth, rubber and plastics.

a)

Class A Fires

b)

Class B Fires

c)

Class C Fires

d)

Class D Fires

e)

Class K Fires

4.

Fires involving flammable liquids and gases.

a)

Class A Fires

b)

Class B Fires

c)

Class C Fires

d)

Class D Fires

e)

Class K Fires

5.

Fires involving energized electrical equipment

a)

Class A Fires

b)

Class B Fires

c)

Class C Fires

d)

Class D Fires

e)

Class K Fires

6.

Fires involving combustible materials such as sodium, magnesium, potassium, and other similar materials.

a)

Class A Fires

b)

Class B Fires

c)

Class C Fires

d)

Class D Fires

e)

Class K Fires

7.

Fires in cooking appliances that involve combustible cooking media (vegetable or animal oils and fats)

a)

Class A Fires

b)

Class B Fires

c)

Class C Fires

d)

Class D Fires

e)

Class K Fires

8.

The aggregate floor area enclosed and bounded by fire walls, fire barriers, exterior walls or fire resistance-rated horizontal assemblies of a building.

a)

Fire Enclosure

b)

Fire Barrier

c)

Fire Area

d)

Fire Barrier Wall

e)

None of the Above

9.

a space within a building that is enclosed by fire barriers on all sides, including the top and bottom

a)

Fire Enclosure

b)

Fire Compartment

c)

Fire Area

d)

Fire Barrier Wall

e)

None of the Above

10.

A written report composed of plans, specifications and design analysis per building prepared by its Engineer/Architect-of-Record and Fire Safety Practitioner

a)

FSCR

b)

FSCCR

c)

FSIC

d)

FSEC

e)

None of the Above

11.

A compilation report of all approved submittals,, test and acceptance forms of all fire protection and life safety features, which shall form part of the "as-built" documents turned over by the contractor to the building owner.

a)

FSCR

b)

FSCCR

c)

FSIC

d)

FSEC

e)

None of the Above

12.

What is FSCR?

(a)  

13.

What is FSIC?

(a)  

14.

A document issued by the BFP as a pre-requisite for the grant of Certificate of Occupancy, Business Permit, Certificate of Annual Inspection from PEZA and other licenses and permits being issued by other government agencies upon determining that the required fire safety construction are in place.

a)

FSIC

b)

FSMR

c)

FSEC

d)

FSCR

e)

None of the Above

15.

any compound or mixture which when applied properly improves the resistivity of fire resistance quality of fabrics and other materials. (RA 9514)

a)

Flame Retardant

b)

Fire Trap

c)

Fumigant

d)

Flame Inhibitor

e)

None of the Above

16.

An Act Establishing A Comprehensive Fire Code of the Philippines, Repealing Presidential Decree No,. 1185 And For Other Purposes

a)

RA 1186

b)

RA 9514

c)

RA 9154

d)

RA 9266

e)

None of the Above

17.

Act that would remove or neutralize a fire hazard

a)

Fire Resistivity

b)

Abatement

c)

Suppression

d)

Fire Exit

e)

None of the Above

18.

 

An integrated system of underground or overhead piping connected to a source of extinguishing agent or medium which when actuated by its automatic detecting device suppresses fire within the area protected even without human intervention.

a)

Fire Prevention System

b)

Fire Suppression Sytem

c)

Standpipe System

d)

Automatic Fire Suppression System

e)

None of the Above

19.

A passageway from one building to another, or through or around a wall in approximately the same floor level.

a)

Horizontal Exit

b)

Fire Exit

c)

Exit

d)

Egress

e)

None of the Above

20.

 

Protective Enclosure of Exit. When an exit is required to be protected by separation from other parts of the building by some requirements of this RIRR, the construction of the separation shall have at least ____ hour fire resistance rating when the exit connects 3 storey or less, regardless of whether the storeys connected are above or below the storey at which the exit discharge begins.

a)

1

b)

2

c)

3

d)

4

e)

None of the Above

21.

 

Doors Clear Opening

a)

700 and 1000mm

b)

750 and 1100mm

c)

710 and 1220mm

d)

800 and 1200mm

e)

None of the Above

22.

A combination of an automatic smoke detection system, automatic exhaust system, and an automatic water curtain.

a)

Spray Nozzle Method

b)

Sprinkler Vent Method

c)

Full Enclosure Method

d)

Partial Enclosure Method

e)

None of the Above

23.

In hotels, what is the travel distance to exits from a guest room or guest suite to a corridor door in buildings not protected by an approved, supervised automatic sprinkler system?

a)

10m

b)

23m

c)

30m

d)

36m

e)

None of the Above

24.

A fire-resistive door prescribed for openings in fire separation walls or partitions

a)

Fire Door

b)

Door Fire

c)

Fire Resistive Door

d)

Door with Fire Retardant

e)

None of the Above

25.

A normally open device installed inside an air duct system which automatically closes to restrict the passage of smoke or fire

a)

Vent

b)

Fire Vent

c)

Fire Trap

d)

Damper

e)

None of the Above

26.

The portion of a roadway or public way that should be kept opened and unobstructed at all times for the expedient operation of fire fighting units.

a)

Fire Alley

b)

Fire Lane

c)

Fire Line

d)

Fire Row

e)

None of the Above

27.

A continuous passageway for the transmission of air.

a)

Air Vent System

b)

Duct System

c)

Air Duct System

d)

Exhaust System

e)

None of the Above

28.

Any visual or audible signal produced by a device or system to warm the occupants of the building or fire fighting elements of the presence or danger of fire to enable them to undertake immediate action to save life and property and to suppress the fire.

a)

Fire Warning System

b)

Fire Siren

c)

Fire Alarm

d)

Fire Strobe

e)

None of the Above

29.

When exits are not immediately accessible from an open floor area, continuous passageways, aisles, or corridors leading directly to every exit shall be maintained and shall be arranged to provide access for each occupant to ____ exit(s) by separate ways of travel.

a)

not less than three (3)

b)

not less than two (2)

c)

one (1)

d)

not less than four (4)

e)

None of the Above

30.

When two (2) exits or exit access doors are required, they shall be located at a distance from one another____ of the length of the maximum overall diagonal dimension of the building or area to be served, measured in a straight line between the nearest edge of the exit doors or exit access doors

a)

not less than one-third (1/3)

b)

10 meters

c)

not less than three-fourths (3/4)

d)

not less than one half (1/2)

e)

None of the Above

31.

The width of any means of egress shall not be less than _____?

a)

300mm

b)

915mm

c)

900mm

d)

660mm

e)

None of the Above

32.

What is the minimum width of corridors?

a)

1.20m

b)

1.38m

c)

2.00m

d)

1.83m

e)

None of the Above

33.

Maximum height of a handrail (in centimeters)?

a)

86.5cm

b)

85.6cm

c)

90.2cm

d)

90.2cm

e)

None of the Above

34.

The minimum temperature at which any material gives off vapor in sufficient concentration to form an ignitable mixture with air?

a)

Boiling Point

b)

Flash Point

c)

Fulmination

d)

Finishing Point

e)

None of the Above

35.

Maximum distance of travel from the high hazard area to an exit (in meters)?

a)

20m

b)

21m

c)

23m

d)

30m

e)

None of the Above

36.

Minimum number of apartment units requiring fire alarm system?

a)

10

b)

12

c)

14

d)

15

e)

None of the Above

37.

A system of vertical pipes to which firehoses can be attached on each floor.

a)

Standpipe System

b)

Riser

c)

Automatic Fire Suppression System

d)

FDAS

e)

None of the Above

38.

Fire Safety Inspection is not required for?

a)

Certificate of Occupancy

b)

Business Permit

c)

Building Permit

d)

Both B and C

e)

None of the Above

39.

If after the building plan review, the plans are disapproved, the Fire Marshall will not

issue the FSEC. What will he/she issue instead?

a)

FALAR 1

b)

FALAR 2

c)

Notice of Disapproval

d)

Notice To Comply

e)

None of the Above

40.

A standpipe system in which pipes are normally not filled with water. Water is introduced into the system through fire service connections when needed

a)

Drought Standpipe

b)

Dry Standpipe

c)

Wet Standpipe

d)

Waterless Standpipe

e)

None of the Above

41.

A wall designed to prevent the spread of fire, having a fire resistance rating of not less than 3 hours with sufficient structural stability to remain standing even if construction on either side collapses under fire conditions.

a)

Shear Wall

b)

Firewall

c)

Structural Wall

d)

Reinforced Concrete Wall

e)

All of the Above

42.

Number if exits for up to 499 occupant load

a)

2

b)

3

c)

4

d)

5

e)

None of the above

43.

Number if exits for 500-1000 occupant load

a)

2

b)

3

c)

4

d)

5

e)

None of the above

44.

Number if exits for 1000 and above occupant load

a)

2

b)

3

c)

4

d)

5

e)

None of the above

45.

Minimum height of headroom

a)

2100mm

b)

2000mm

c)

2400mm

d)

2500mm

e)

None of the above

46.

Existing stairs minimum run and maximum riser?

a)

min. run: 230mm

max. riser: 205mm

b)

min. run: 280mm

max. riser: 180mm

c)

min. run: 250mm

max. riser: 250mm

d)

min. run: 200mm

max. riser: 250mm

e)

None of the Above

47.

New stairs minimum run and maximum riser?

a)

min. run: 230mm

max. riser: 205mm

b)

min. run: 280mm

max. riser: 180mm

c)

min. run: 250mm

max. riser: 250mm

d)

min. run: 200mm

max. riser: 250mm

e)

None of the Above

48.

What is the minimum clear width for ramps?

a)

1200mm

b)

1100mm

c)

1120mm

d)

1210mm

e)

None of the Above

49.

What is the maximum slope for ramps?

a)

1:15

b)

1:12

c)

1:8

d)

1:10

e)

None of the Above

50.

A mechanical device which when pushed from the inside will cause the door to open

a)

Safety Device

b)

Panic Hardware

c)

Panic Device

d)

Panic Equipment

e)

None of the Above