WorksheetsBL M-03 BP 344 FLASHCARD 02
Total questions: 50
Worksheet time: 2hrs 40mins
Gratings should be located along walkways
True
Probably
False
Maybe
What is the maximum dimension of grating openings and shall not project more than ____ above the level of the walkway.
10mmx10mm - 7mm
10mmx10mm - 6.5mm
13mmx13mm - 7mm
13mmx13mm - 6.5mm
For all excavations, the height of the top of the rail should be at least ____ above the adjacent surface.
2.0m
1.5m
0.80m
1.0m
For all excavations, the railing should incorporate a tapping rail to assist the blind that should not be greater than ____ above adjacent surface.
0.40m
0.35m
0.45m
0.30m
For all excavations, If the temporary covering is properly supported by cross beams, the sides should be ramped if projecting is more than ____.
15mm
20mm
25mm
30mm
For all excavations, The effective width of footways past any obstruction should not be less than ____.
1.20m
1.30m
1.50m
1.35m
For all excavations, Loose materials should be fenced by a kickboard at least _____. It will serve as a tapping board for the blind.
0.10m
0.20m
0.30m
0.40m
Signs should be located on verges or similar whenever these are available.
False
Maybe
True
Probably
Signs should not reduce the available footway width to less than ____.
2.0m
1.30m
1.40m
1.20m
What defines the back of a walkway?
Planting Strip
Plants
Tapping Rail
Edge of Ramp
What should be the color for the Symbols in signages for pedestrian suitable for the disabled?
White
Yellow
Black
Red
What should be the color for the background in signages for pedestrian suitable for the disabled?
White
Blue
Black
Red
Signs on walls and doors should be located at a maximum height of ____.
1.30m
1.50m
1.60m
1.40m
Signs on walls and doors should be located at a minimum height of ____.
1.30m
1.50m
1.60m
1.40m
Should a sign protrude into a walkway or route, a minimum headroom of ____ should be provided.
2.0m
1.80m
1.50m
2.20m
What is the minimum height for signages labeling public rooms and places that has a raised symbols, letters or numbers?
2 mm
1 mm
3 mm
4 mm
What does a rectangular signboard indicates?
warnings
prohibitions
safety precautions
guidelines
What does a circular signboard indicates?
warnings
prohibitions
safety precautions
guidelines
In case entrances are not on the same level of the site arrival grade, ramps should be provided as access to the entrance level
False
Maybe
True
Probably
What is the depth and width to be provided for entrances with vestibules?
2.0m x 1.40m
1.80m x 1.40m
2.0m x 1.50m
1.80m x 1.50m
Ramps shall be equipped with curbs on both sides with a minimum height of ____.
0.10m
0.20m
0.30m
0.40m
Any ramp with a rise greater than 0.20 m. and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not less than ___ meters from the foot of the ramp
1.20m
1.30m
1.50m
1.60m
As per B.P 344, handrails shall be installed at how many meters above steps or ramps?
0.90 m and 0.70 m
0.90 m and 0.80 m
0.80 m and 0.70 m
0.80 m and 0.75 m
As per B.P 344, what is the maximum ramp gradient?
1:10
1:3
1:12
1:15
As per B.P 344, what is the maximum length of a ramp?
12 m
6 m
15 m
30 m
Longer ramps whose gradient is more than the maximum shall be provided with a landing not less then ___.
1.80 m
1.50 m
1.40 m
1.60 m
What is the minimum clear width of ramps?
1.10
1.40
1.20
1.30
A level area should be provided at the top and bottom of any ramp of not less than ____.
1.40
1.50
2.0
1.80
For accessible ramps 3m or more in width, provide ____ at the center.
Transition Handrail
Integrated Handrail
Intermediate Handrail
Extension Handrail
Handrails shall be required for accessible ramps for changes in grade higher than ____.
170mm
180mm
190mm
160mm
A ____ long extension of the handrail should be provided at the start and end of ramps and stairs.
0.20 m
0.30 m
0.40 m
0.50 m
Handrails that require full grip should have a dimension of ____ to ____.
20 to 50mm
30 to 50mm
40 to 60mm
30 to 60mm
Handrails attached to walls should have a clearance no less than ____ from the wall.
40 mm
30 mm
50 mm
60 mm
Handrails on ledges should have a clearance not less than ____.
40 mm
30 mm
50 mm
60 mm
As per B.P 344, corridors shall have a minimum clear width of? (shall not obstruct the minimum clearance requirement.)
1.10 m
1.20 m
1.25 m
1.35 m
What is the minimum clear width of doors?
1.00
0.70
0.80
0.90
What is the preferred/recommended clear width of doors?
1.00
0.70
0.80
0.90
Doors should be operable by a pressure of force not more than how many kg?
1 kg
2 kg
3 kg
4 kg
What is the minimum clear level space to be provided before and extending beyond a door as per B.P 344?
1.20 m x 1.20 m
2.50 m x 1.50 m
1.50 m x 1.50 m
2.70 m x 1.20 m
Recesses or turnabout spaces should be provided for wheelchairs to turn around or to enable another wheelchair to pass; these spaces shall have a minimum area of?
1.20 m to 1.20 m
1.50 m to 1.50 m
2.50 m to 1.50 m
2.70 m to 1.20 m
Recesses or turnabout spaces should be provided for wheelchairs to turn around and shall be spaced at a maximum of ___.
12 m
10 m
6 m
3.50 m
Turnabout spaces should also be provided at or within of every dead end within ___.
12 m
10 m
6 m
3.50 m
The minimum height of door thresholds
25 mm
30 mm
50 mm
100 mm
Doorknobs and other hardware should be located between ____ m. and ____ m. above the floor.
0.80 m - 1.05 m
0.82 m - 1.06 m
0.75 m - 1.00 m
0.85 m - 1.05 m
The preferred Doorknobs and other hardware is ____.
1.06m
1.0m
0.90m
0.80m
Vertical pull handles, centered at ____ above the floor, are preferred to horizontal bars for swing doors or doors with locking devices.
1.06m
1.0m
0.90m
0.80m
Doors along major circulation routes should be provided with a kick plate made of durable materials at a height of ___.
0.20 m to 0.30 m
0.30 m to 0.40 m
0.15 m to 0.25 m
0.35 m to 0.45 m
Doors with peepholes, provide a secondary peephole at a height of ____ from the finish floor for wheelchair users.
0.90m
1.0m
1.1m
1.2m
Manual switch should be located from the latch side of the door about ____.
200 mm
300 mm
250 mm
350 mm
Manual switches should be positioned above the floor within ____.
1.20 m to 1.30 m
1.30 m to 1.40 m
1.15 m to 1.25 m
0.920 m to 1.20 m
