WorksheetsBL M-02 FIRE CODE FLASHCARDS 02
Total questions: 51
Worksheet time: 26mins
When was the Fire Code of the Philippines effective?
Nov 17, 2009
Jan 20, 2009
Jan 19, 2008
Nov 20, 2004
None of the Above
When was the IRR of RA 9514 effective?
Nov 17, 2009
Jan 20, 2009
Jan 19, 2008
Nov 20, 2004
None of the Above
Which is not covered by RA 9514?
All persons
design and installation of MEPS relative to Fire Protection
Fire safety planning, design, construction, repair, maintenance, rehabilitation and demolition
Petroleum industry installation
None of the Above
What is FALAR?
Fire and Life Assessment Report
Fire Alarm Location And Route
Fire and Life Safety Assessment Report
Fire Assessment And Life Safety Assurance Report
None of the Above
Required for all private and public buildings, facilities and structures to be constructed or being constructed
FALAR 1 & 2
FALAR 1 & 3
FALAR 2 & 3
FALAR 1
None of the Above
Required for all existing private and public buildings, facilities or structures with occupancy of at least 50 persons.
FALAR 1 & 2
FALAR 1 & 3
FALAR 2 & 3
FALAR 3
None of the Above
Any qualified person, recognized by the BFP, engaged in, but not limited to, the design, construction, installation, repair, and maintenance, assessment, and rehabilitation of fire safety construction, suppression and control systems, or employed as a safety officer of public and private establishments/companies.
Fire Safety Officer
Fire Safety Practitioner
Fire Safety Inspector
Fire Safety Chief
None of the Above
A collective term that is used to refer to a group of firefighters, primarily performing fire suppression activities in areas such as but not limited to community/barangay, company, and other government and non-government establishments.
Fire Volunteer
Fire Volunteer Organization (FVO)
Fire Brigade
Fire Fighters
None of the Above
An organized group of private firefighters recognized by the BFP, who have voluntarily formed themselves to perform fire-related activities
Fire Volunteer
Fire Volunteer Organization (FVO)
Fire Brigade
Fire Fighters
None of the Above
A person who voluntarily enters into firefighting service through a Fire Volunteer discipline as that of BFP firefighters
Fire Volunteer
Fire Volunteer Organization (FVO)
Fire Brigade
Fire Fighters
None of the Above
All business establishments employing at least ____ persons shall establish an organization of fire brigade to deal with fire and other related emergencies.
50
100
30
40
None of the Above
Any condition or act which increases or may cause an increase in the probability of the occurrence of fire, or which may obstruct, delay, hinder or interfere with fire fighting operations and the safeguarding of life and property
Fire Trap
Fire Hazard
Fire Spread
Flammability
None of the Above
any street, alley or other strip of land unobstructed from the ground to the sky, deeded, dedicated or otherwise permanently appropriated for public use.
Public Area
Public Access
Public Way
Public Lane
None of the Above
time in which flame will spread over the surface of a burning material
Fire Resistance Rating
Flame Spread Rating
Smoke Developed Rating
Fire Spreading Rating
None of the Above
time duration that a material or construction can withstand the effect of a hundred fire test
Fire Resistance Rating
Flame Spread Rating
Smoke Developed Rating
Fire Spreading Rating
None of the Above
a rating of combustible material based on the density and volume of smoke developed within a certain period of time when its surface is ignited
Fire Resistance Rating
Flame Spread Rating
Smoke Developed Rating
Fire Spreading Rating
None of the Above
means of egress that leads from any occupied point in the building or structure to an exit
Exit Access
Exit
Exit Discharge
Exit Components
None of the Above
portion of a means of egress that is separated by construction or equipment as required to provide a protected way of travel to an exit discharge.
Exit Access
Exit
Exit Discharge
Exit Components
None of the Above
portion of a means of egress between the termination of an exit and a public way
Exit Access
Exit
Exit Discharge
Exit Components
None of the Above
shall be constructed as an integral part of the building or shall be permanently affixed thereto
Exit Access
Exit
Exit Discharge
Exit Components
None of the Above
a passageway serving as a required exit, enclosed by walls of fire-resistive construction
Exit Corridor
Exit Door
Exit Staircase
Exit Passageway
None of the Above
door providing access to a means of egress, swinging in the direction of exit travel and usually equipped with a panic hardware
Exit Corridor
Exit Door
Exit Staircase
Exit Passageway
None of the Above
a stairway leading to an exit passageway, exit court, or a public way having no openings other than required exits and enclosed by fire-resistive construction as required for the walls, floors and ceiling of the building served
Exit Corridor
Exit Door
Exit Staircase
Exit Passageway
None of the Above
a yard or court providing egress to a public way for one or more required exits.
Exit Corridor
Exit Court
Exit Staircase
Exit Passageway
None of the Above
what is the fire resistance rating needed for 3 stories or less
3-hour
2-hour
1-hour
1 1/2-hour
None of the Above
what is the fire resistance rating needed for 4 or more stories?
3-hour
2-hour
1-hour
1 1/2-hour
None of the Above
The maximum number of persons that may be in the space at any time
Maximum Occupant Load
Maximum Load
Occupant Load
Occupancy Load
None of the Above
the number computed by dividing the floor area assigned to that use by the occupant load factor
Maximum Occupant Load
Maximum Load
Occupant Load
Occupancy Load
None of the Above
projections of not more that ____ at a maximum height of ____mm within the means of egress on each side shall be permitted.
120mm; 900mm
115mm; 850mm
150mm;960mm
114mm;965mm
None of the Above
(2 exits or exit access doors) shall be located at a distance from one another note less than ____ of the length of the maximum overall diagonal dimension of the building
3/4
1/2
2/3
1/4
None of the Above
In buildings protected throughout by an approved supervised automatic sprinkler system, the minimum separation distance between two exits or exit access doors shall not be less than ____ the length of the maximum overall diagonal dimension of the building.
3/4
1/2
1/3
1/4
None of the Above
What is the minimum travel distance to an exit if the building is not protected with AFSS?
30m
46m
52m
61m
None of the Above
What is the minimum travel distance to an exit if the building is protected with AFSS?
30m
46m
52m
61m
None of the Above
A door from a room to an exit or to a way of exit access shall be of the ____?
dual-hinge, swinging type
side-hinge, swinging type
side-hinge, sliding type
single-hinge, sliding type
None of the Above
A door from a room to an exit or to a way of exit access shall swing with exit travel for ____ occupant load.
50+
10+
100+
60+
None of the Above
Where shall all exits terminate directly?
public way or fire lane
fire lane
exit discharge or exit corridor
public way or exit discharge
None of the Above
An area affording safety from fire or smoke coming from the area from which escape is made
Area of Safety
Center of Refuge
Area of Refuge
Safety Space
None of the Above
during its swing, any door in a means of egress shall leave not less than _____of the required width of an aisle, corridor, passageway, or landing unobstructed
1/2
1/3
1/4
2/3
None of the Above
There shall be reentry mechanism every ____ that provide a way out of the exit stairway
2 floors
3 floors
4 floors
5 floors
None of the Above
The elevation of the floor surfaces on both sides of a door shall not vary by more than ____?
1.2cm
1.5cm
1.15cm
1.3cm
None of the Above
Thresholds at doorways shall not exceed ____ in height
1.2cm
1.5cm
1.15cm
1.3cm
None of the Above
Raised thresholds and floor level changes in excess of ___ doorways shall be beveled with a slope not steeper than 1 in 2
10mm
5mm
6mm
9mm
None of the Above
Total cumulative occupant load assigned to the stair width for less than 2000 persons (in mm)
1200mm
1120mm
1000mm
1150mm
None of the Above
Total cumulative occupant load assigned to the stair width for more than 2000 persons (in mm)
1420mm
1500mm
1450mm
1520mm
None of the Above
maximum height between landings for existing stairs
3600mm
2550mm
3660mm
2880mm
None of the Above
Curved stairs shall be permitted as a component in a means of egress provided that the depth of tread is not less than ____ at a point ____ from the narrowest end of the tread.
290mm ; 310mm
250mm ; 300mm
240mm; 320mm
280mm ; 305mm
None of the Above
Curved stairs shall be permitted as a component in a means of egress provided that the smallest radius is not less than _____
half the stair width
twice the stair width
thrice the stair width
a third of the stair width
None of the Above
Spiral Stairs: riser height and tread depth
160mm;180mm
200mm;200mm
180mm;280mm
170mm;250mm
None of the Above
Spiral Stairs: at the outer side of the stairways, an additional ____ of width shall be provided clear to the other handrail
260mm
265mm
250mm
275mm
None of the Above
Which side is the outer handrail of descending users for spiral stairs?
depends on orientation
left
right
diagonal
None of the Above
every tread less than 25cm shall have a nosing or an effective projection of approximately ____over the level immediately below.
30mm
25mm
12.7mm
23mm
None of the Above