Worksheets

BL M-01 NBCP FLASHCARD 05

Total questions: 50

Worksheet time: 50mins

Name
Class
Date
1.

Maximum rise of stair step

a)

20 m

b)

200 mm

c)

2 cm

d)

200 cm

2.

Minimum run of stair step

a)

25 m

b)

250 mm

c)

2.5 cm

d)

250 cm

3.

Total width of stairs with more than 50 occupant load

a)

1.20 m

b)

1.10 m

c)

0.90 m

d)

0.75 m

4.

Total width of stairs with less than 50 occupant load

a)

1.20 m

b)

1.10 m

c)

0.90 m

d)

0.75 m

5.

Total width of stairs with less than 10 occupant load

a)

1.20 m

b)

1.10 m

c)

0.90 m

d)

0.75 m

6.

Width of Aisle A

a)

600 mm

b)

800 mm

c)

1000 mm

d)

1100 mm

7.

Width of Aisle B

a)

600 mm

b)

800 mm

c)

1000 mm

d)

1100 mm

8.

Width of Aisle C

a)

600 mm

b)

800 mm

c)

1000 mm

d)

1100 mm

9.

Minimum spacing of rows for standard seating from back-to-back

a)

810 mm

b)

820 mm

c)

830 mm

d)

840 mm

10.

Minimum spacing of rows of seats for bleachers measured back-to-back in open stands without backrests

a)

600 mm

b)

650 mm

c)

750 mm

d)

850 mm

11.

Minimum spacing of rows of seats for bleachers measured back-to-back in open stands with backrests

a)

600 mm

b)

650 mm

c)

750 mm

d)

850 mm

12.

Minimum spacing of rows of seats for bleachers measured back-to-back in open stands with chair seating

a)

600 mm

b)

650 mm

c)

750 mm

d)

850 mm

13.

Maximum rise of bleachers

a)

400 mm

b)

450 mm

c)

475 mm

d)

500 mm

14.

Width of any seating

a)

450 - 480 mm

b)

480 - 500 mm

c)

400 - 450 mm

d)

450 - 500 mm

15.

Pipe Color of Air (Low Pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

16.

Pipe Color of Argon (Low Pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

17.

Pipe Color of Helium (Low Pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

18.

Pipe Color of Nitrogen (Low Pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

19.

Pipe Color of Water (Cold)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

20.

Pipe Color of Water (Distilled)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

21.

Pipe Color of Water (Low-Pressure) (Excl. Of fire Service)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

22.

Pipe Color of Water (Treated)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

23.

Pipe Color of Oil and Water (For hydraulic system) (2 answers)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

24.

Pipe Color of Acetylene

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

25.

Pipe Color of Blast Furnace Glass

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

26.

Pipe Color of Gasoline

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

27.

Pipe Color of Grease

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

28.

Pipe Color of Hydrogen

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

29.

Pipe Color of Oxygen

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

30.

Pipe Color of Oil

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

31.

Pipe Color of Tar

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

32.

Pipe Color of Producer Gas

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

33.

Pipe Color of Liquid Petroleum Gas

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

34.

Pipe Color of Vacuum (High)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

35.

Pipe Color of Carbon Dioxide

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

36.

Pipe Color of Water (Fire Service)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

37.

Pipe Color of Acid

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

38.

Pipe Color of Air (High pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

39.

Pipe Color of Ammonia

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

40.

Pipe Color of Steam (High Pressure) & Steam (Low Pressure)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

41.

Pipe Color of Water (Boiler Feed), Water (Hot), & Water (High Pressure) (Excl. of Fire service)

a)

ORANGE

b)

GREEN

c)

YELLOW

d)

RED

42.

A sign that directs attention to a business, profession, commodity, service or entertainment conducted, sold or offered at a place other than where the business, profession, etc., is located; An off-premise sign.

a)

ADVERTISING SIGN

b)

BILLBOARD

c)

DISPLAY SIGN

d)

GROUND SIGN

43.

A panel for posting bills or posters.

a)

ADVERTISING SIGN

b)

BILLBOARD

c)

DISPLAY SIGN

d)

GROUND SIGN

44.

Any material, device or structure that is arranged, intended, designed, or used as an advertisement, announcement or directory that includes a sign, sign screen, billboard or advertising device of any kind. An on-premise sign.

a)

ADVERTISING SIGN

b)

BILLBOARD

c)

DISPLAY SIGN

d)

GROUND SIGN

45.

A sign with its support resting on the ground, the base of which ranges from a single pole (plyon) and does not exceed 10.00 sq. meters as one (1) unit.

a)

ADVERTISING SIGN

b)

BILLBOARD

c)

DISPLAY SIGN

d)

GROUND SIGN

46.

A sign fastened to, suspended from or supported on a building or structure the

display surface of which is perpendicular from the wall surface or is at an angle therefrom.

a)

PROJECTING SIGN

b)

ROOF SIGN

c)

WALL SIGN

d)

TEMPORARY SIGN

47.

A sign installed on roofs, roof decks, the horizontal least cross sectional area in case of supporting frame does not exceed 10.00 sq. meters for such framed structure resting entirely on the roof.

a)

PROJECTING SIGN

b)

ROOF SIGN

c)

WALL SIGN

d)

TEMPORARY SIGN

48.

A sign painted on, attached or fastened to the surface of the wall or any part of a building or structure the display surface of which is parallel to the wall surface.

a)

PROJECTING SIGN

b)

ROOF SIGN

c)

WALL SIGN

d)

TEMPORARY SIGN

49.

A sign of cloth or other light and/or combustible material, with or without frame such as streamer, bills, posters and the like installed for a limited period of time.

a)

PROJECTING SIGN

b)

ROOF SIGN

c)

WALL SIGN

d)

TEMPORARY SIGN

50.

Minimum headroom for stairs

a)

2000mm

b)

3600mm

c)

1000mm

d)

1500mm