APU fire in flight is normally extinguished?
Manually from APU FIRE panel.
Automatically by the FDU.
Automatically when fire handle ispulled.
APU fire on ground is normally extinguished:
From APU FIRE panel.
Automatically.
From EXTERNAL POWER panel.
Can you use the LH fire extinguisher bottlesfor RH engine fire?
Yes.
Yes, if two fire extinguisher bottles of RHengine have been discharged.
No.
Each engine fire loop comprises:
Fan fire detector, core fire detector andpylon fire detector
Fan fire detector and pylon fire detector
Core fire detector only
Engine loop A & B are connected to the FDU:
Serial
Parallel
ARINC 429 bus
In case of smoke detection, the smokedetector activates:
GEN 1 LINE SMOKE, BLOWER FAULT andEXTRACT FAULT lights on.
GEN 1 LINE SMOKE light on.
BLOWER FAULT and EXTRACT FAULTlights on.
Loop failure warning are sent to:
ECAM and CFDS
CFDS only
ECAM and fire panel
The A/C on ground, the APU fire warningsignals are sent to:
ECAM, APU fire panel and externalpower control panel
ECAM, APU fire panel
APU fire panel and external powercontrol panel
The DISCH light on engine fire panel comes onwhen:
The agent has been discharged
Engine fire PB is released out
Fire is on the engine
The fire extinguishing agent pressure ismonitored by:
A pressure switch.
A red light in the cockpit.
A red disk on the pylon.
The fire warning signals are sent to:
ECAM, Engine fire panel and start control panel
Engine fire panel and ECAM
ECAM and start control panel
The lavatory & cargo smoke detectors aremonitored by:
FDU
SDCU
SDF function in CIDS director (enhanceaircraft)
The lavatory fire protection is provided by:
The lavatory automatic extinguishing.
The lavatory smoke detection system.
The lavatory smoke detection system and the waste bin automatic extinguishing.
The number of APU fire detectors is:
Three.
Two, connected in parallel.
Two, connected in serial.
The Test PB on the engine fire panel checksthe integrity of the:
Fire detection loops A & B, FDU,indications and warnings
Squib circuit continuity
Both A & B
Thermal discharge of the APU bottle be detected:
By the FDU.
By the ECAM.
By the red disc indicator.
When the ENG FIRE PB is released out?
Both Squib lights come on and A/C systems are isolated
A/C system are isolated and Fire bottles discharge
Fire bottles discharge
Where is lavatory smoke detector located?
In the ceiling panel, beside the air extraction duct
In the waste bin
In the air extraction duct
Where is the Avionics smoke detectorinstalled?
On the air extraction duct of the avionicsventilation system
On the air inlet duct of the avionicsventilation system
In the Avionics compartment ceiling
Which warning lights are triggered in case ofan avionic smoke detection?
GEN 1 LINE SMOKE light.
BLOWER and EXTRACT FAULT lights.
Both A & B.