NEW
Font size
WorksheetsBUILDING LAWS
Total questions: 55
Worksheet time: 41mins
Maximum Block length of a subdivision as per BP 220
450
400
500
550
Which is not a basic needs in settlements?
School
Power
Storm Drainage
Movement and Circulation
Housing program for the homeless and disadvantaged sector
Affordable cost housing program
Socialized Housing
Economic Housing
Subdivision
Housing program for average and low income families
Affordable cost housing program
Socialized Housing
Economic Housing
Subdivision
Maximum block length of rowhouses
250 m
50 m
150 m
100 m
It was created in relation with the Philippine Constitution where it says that the "State shall establish, maintain, and ensure adequate social services in the field of housing to guarantee the enjoyment of the people of a decent standard living"
National Housing Authority (NHA)
HLURB
UDHA
LGU
Handrails that require full grip should have a dimension of ____
50-75mm
30-50mm
25-50mm
50-60mm
Handrails on ledges should have a clearance not less than ____
35mm
40mm
45mm
50mm
Should a sign protrude into walkways or route, a minimum headroom of __ should be provided
2.1m
2m
1.8m
2.4m
Accessible parking slots should have a minimum width of __m
5
3.7
3.5
2.5
Minimum width of drop curb
1800mm
900mm
1200mm
1500mm
Minimum width of curb cut-out
1800mm
900mm
1200mm
1500mm
Preferred depth of central refuges
1.2 m
1.8 m
1.5 m
2 m
Maximum cross gradient of walkways and passageways
1:12
1:20
1:100
1:10
___mm caliper diameter trees shall be preserved as per as part or planning consideration for BP 220
300 mm
250 mm
500 mm
200 mm
Maximum selling price for horizontal development of a socialized housing
₱ 450,000
₱ 400, 000
₱ 500, 000
₱ 1,700,000
Maximum selling price for vertical development of a socialized housing
₱ 450,000
₱ 400, 000
₱ 500, 000
₱ 1,700,000
Maximum selling price for vertical development of an economic housing
₱ 1, 550,000
₱ 1, 400, 000
₱ 1, 500, 000
₱ 1,700,000
Minimum size of a collector road
8 meters
9 meters
10 meters
12 meters
Minimum size of a collector road
8 meters
9 meters
10 meters
12 meters
Minimum size of an interconnecting road
8 meters
9 meters
10 meters
12 meters
Minimum size of a motor court road
8 meters
9 meters
6 meters
4 meters
Minimum size of a minor road
6.5 meters
3 meters
4 meters
8.5 meters
Minimum size of a minor road
6.5 meters
3 meters
4 meters
8.5 meters
Both sides of subdivision entrances must provide __ length and __ depth to accommodate loading and unloading of passengers
3 x 5 m
1.8 x 5 m
4 x 3 m
3.5 x 6 m
Both sides of subdivision entrances must provide __ length and __ depth to accommodate loading and unloading of passengers
3 x 5 m
1.8 x 5 m
4 x 3 m
3.5 x 6 m
A short road that is blocked off at one end
Dead-Road
Interconnecting Road
Alley
Cul-de-sac
Maximum length of a cul-de-sac?
150 m
100 m
120 m
200 m
Price of saleable lots intended for single detached units shall not exceed __ of the maximum selling price of the house and lot package
30%
50%
25%
40%
Minimum floor area of an economic house
22 sqm
18 sqm
36 sqm
48 sqm
Minimum floor area of a socialized house
22 sqm
18 sqm
24 sqm
10 sqm
Minimum front, side and rear setbacks of a socialized and economic houses
Front : 1.5 m
Side: 1.5 m
Rear : 2.0 m
Front : 2.5 m
Side: 1.5 m
Rear : 1.5 m
Front : 1.5 m
Side: 2.0 m
Rear : 2.0 m
Front : 4 m
Side: 1.5 m
Rear : 1.5 m
Minimum front, side and rear setbacks of a socialized and economic houses
Front : 1.5 m
Side: 1.5 m
Rear : 2.0 m
Front : 2.5 m
Side: 1.5 m
Rear : 1.5 m
Front : 1.5 m
Side: 2.0 m
Rear : 2.0 m
Front : 4 m
Side: 1.5 m
Rear : 1.5 m
BP 220 developments shall have an independent water supply system at ___
150 liters/capita/day
120 liters/capita/day
200 liters/capita/day
180 liters/capita/day
BP 220 developments shall have an independent water supply system at ___
150 liters/capita/day
120 liters/capita/day
200 liters/capita/day
180 liters/capita/day
Minimum lot area of a single detached economic house
36 sqm
72 sqm
54 sqm
64 sqm
Minimum lot area of a row house economic house
36 sqm
28 sqm
54 sqm
64 sqm
Minimum lot area of a row house socialized house
36 sqm
28 sqm
54 sqm
64 sqm
Minimum lot frontage of an economic and socialized housing situated in a corner lot
6 m
8 m
10 m
4 m
Minimum lot frontage of an economic and socialized housing situated in an irregular lot
6 m
8 m
3 m
4 m
Minimum lot frontage of an economic and socialized housing situated in a regular lot
6 m
8 m
3 m
4 m
Minimum headroom clearance as per BP 220
1.8 m
2.0 m
2.1 m
2.4 m
Minimum headroom clearance as per BP 220
1.8 m
2.0 m
2.1 m
2.4 m
Minimum width of a corridor as per BP 220
1 m
0.9 m
1.10 m
1.20 m
Minimum clear width of stairs for a BP 220 housing
600 mm
750 mm
800 mm
850 mm
Height of handrails on stairs for BP220 housing
1.0m - 1.06 m
0.70m -0.9 m
0.90m - 1.20 m
0.80m - 1.20 m
Minimum height of a main and service door as per BP 220
2.10m
2.0 m
1.8 m
1.85 m
Minimum clear width of a main and service door as per BP 220
Main Door - 0.80m
Service Door - 0.7 m
Main Door - 0.80m
Service Door - 0.75 m
Main Door - 0.90m
Service Door - 0.8 m
Main Door - 0.80m
Service Door - 0.8 m
As per the BP 220, the maximum height of window bottom/ sill is ___
1.22 m
1. 50 m
0.9 m
1.10m
Minimum thickness of a firewall for BP 220
150 mm
200 mm
250 mm
180 mm
The extension above the roof and sides of a firewall for BP220 housing
400 mm
300 mm
600 mm
200 mm
As per BP 220, an elevator is required for condominium ___ storeys above
5 Storeys
6 Storeys
3 Storeys
It is not required
To ensure to adequately maintain light and ventilation, what is the minimum distance between buildings for 3-4 storeys as per BP 220
4 meters
6 meters
10 meters
8 meters
As per BP 220, the clearance between the roof eaves shall be ___
1 m
1. 5 m
2 m
2.5 m
What is the required parking slot for BP 220 living units? 1 parking slot per __
1 slot per 5 units
1 slot per 10 units
1 slot per 8 units
1 slot per 12 units