wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Quiz: National Building Code (NBC) - Part 1

Total questions: 52

Worksheet time: 26mins

Name
Class
Date
1.

Under the NBC, every room for any use without artificial ventilation must have window opening area equal to what percent of the room floor area?

a)

12 percent of floor area

b)

10 percent of floor area

c)

8 percent of floor area

d)

5 percent of floor area

2.

Which construction type has four-hour fire-resistive performance throughout with structural elements of steel, iron, concrete, or masonry?

a)

Type III construction

b)

Type IV construction

c)

Type V construction

d)

Type VI construction

3.

In site planning abbreviations, PSO plus TOSL equals which total?

a)

TLA

b)

TFA

c)

GFA

d)

FAR

4.

In the NBC, the term for the total number of persons that may occupy a building or a portion at any one time is called what?

a)

Egress demand

b)

Population count

c)

Occupant load

d)

Seating capacity

5.

Inner courts must connect to a street or yard via a passage with a minimum width of how much?

a)

0.90 meters minimum

b)

1.20 meters minimum

c)

1.50 meters minimum

d)

1.80 meters minimum

6.

For interior lots, required open spaces under the NBC are what percentages for A,B,C,D,J occupancies and for E,F,G,H,I occupancies, respectively?

a)

50% for A–D,J and 20% for E–I

b)

40% for A–D,J and 10% for E–I

c)

60% for A–D,J and 30% for E–I

d)

70% for A–D,J and 25% for E–I

7.

Rooms for human habitation under the NBC shall have a minimum dimension of?

a)

1.80 m

b)

2.00 m

c)

2.50 m

d)

3.00 m

8.

Under the NBC, what is the minimum front setback for a residential building in an R-1 zone?

a)

5.00 m

b)

2.00 m

c)

4.50 m

d)

3.00 m

9.

For Group A Dwellings, what is the minimum stair width required?

a)

900 mm

b)

750 mm

c)

800 mm

d)

700 mm

10.

For Group A Dwellings, what is the maximum stair rise?

a)

250 mm

b)

175 mm

c)

225 mm

d)

200 mm

11.

For Group A Dwellings, what is the minimum clear width of stairs?

a)

800 mm

b)

750 mm

c)

650 mm

d)

700 mm

12.

What form must be secured prior to occupying any structure?

a)

Certificate of Completion

b)

Certificate of Occupancy

c)

Occupancy Clearance

d)

Final Inspection Report

13.

Under the NBC, what percent of the floor area must window openings equal at minimum?

a)

12%

b)

8%

c)

10%

d)

5%

14.

Under the NBC, open spaces for corner and through lots must be at least what percent?

a)

12%

b)

10%

c)

8%

d)

5%

15.

Habitable rooms with artificial ventilation must have ceiling heights not less than how many meters measured from floor to ceiling?

a)

2.20 m

b)

2.40 m

c)

3.00 m

d)

2.70 m

16.

Under the NBC, basic residential buildings in an R-2 zone shall have a minimum front setback of:

a)

3.00 m

b)

2.00 m

c)

4.00 m

d)

4.50 m

17.

The clearance between established street grade and the lowest part of a balcony soffit shall not be less than:

a)

4.00 m

b)

2.50 m

c)

3.00 m

d)

3.50 m

18.

Bath and toilet shall have a minimum area of what, with a least dimension of 900 mm?

a)

2.00 sqm

b)

1.20 sqm

c)

1.00 sqm

d)

1.50 sqm

19.

Repair garages are classified under which occupancy group under the NBC?

a)

Business and Storage

b)

Assembly and Industrial

c)

Industrial and Hazardous

d)

Storage and Hazardous

20.

Under PD 1096, buildings of masonry and wood with one-hour fire-resistivity and incombustible exterior walls are classified as which type?

a)

Type I

b)

Type IV

c)

Type II

d)

Type III

21.

Works that change partitions, openings, structural parts, utilities, or equipment without increasing building height or floor area are referred to as:

a)

Renovation

b)

Alteration

c)

Repair

d)

Retrofit

22.

The required open space between the outermost face of the building and the property lines (front, rear, right, left) is called the:

a)

Buffer

b)

Setback

c)

Yard

d)

Easement

23.

An unoccupied space other than a yard, bounded on three sides by building lines with one side open to another open space, is called:

a)

Light well

b)

Open court

c)

Pocket garden

d)

Service court

24.

Under the NBC, the minimum dimension for the court or near yard from the property line to the face of the building is:

a)

2.50 m

b)

1.50 m

c)

3.00 m

d)

2.00 m

25.

Under the NBC, open spaces for inside lots are at least what percent for Groups A, B, C, D, and J?

a)

25%

b)

10%

c)

15%

d)

20%

26.

Under the NBC, open spaces for inside lots are at least what percent for Groups E, F, G, H, and I?

a)

20%

b)

15%

c)

25%

d)

10%

27.

PSO + ISA is equal to:

a)

MACA

b)

FAR

c)

GFA

d)

TLA

28.

The width of the yard is termed the:

a)

Frontage

b)

Reserve

c)

Setback

d)

Easement

29.

Which term refers to total floor space within the perimeter of permanent external building walls?

a)

Impervious surface area

b)

Gross floor area

c)

Net habitable area

d)

Usable floor area

30.

Under the NBC, rooms for human habitation shall have a minimum size of how many square meters?

a)

8 sqm

b)

6 sqm

c)

5 sqm

d)

4 sqm

31.

What refers to the percentage of the maximum allowable floor area of paved, tiled, or hardscaped surface at ground/grade level relative to the Total Lot Area?

a)

Usable Site Area

b)

Building Coverage Ratio

c)

Impervious Surface Area

d)

Total Open Space

32.

Under the NBC, mezzanine floors shall have a clear ceiling height not less than how much?

a)

2.10 m

b)

1.80 m

c)

1.50 m

d)

2.40 m

33.

Minimum air space for school rooms is specified as what volume?

a)

14 cu.m

b)

10 cu.m

c)

3 cu.m

d)

2 cu.m

34.

Under the NBC, the minimum dimensions for a parking space are which of the following?

a)

2.20 m x 4.50 m

b)

2.50 m x 5.00 m

c)

2.80 m x 5.40 m

d)

3.00 m x 6.00 m

35.

Minimum side setback for R-2 residences is how much?

a)

1.50 m

b)

2.50 m

c)

3.00 m

d)

2.00 m

36.

Under the NBC, the vertical distance between landings shall not be more than what measurement?

a)

4.20 m

b)

3.00 m

c)

2.40 m

d)

3.60 m

37.

Under PD 1096, factories and workshops using less flammable or non-combustible materials are classified under which occupancy?

a)

Storage and hazardous

b)

Business and mercantile

c)

Industrial

d)

Utility and miscellaneous

38.

In each city, who implements the National Building Code according to PD 1096?

a)

Fire marshal

b)

Building officials

c)

City architect

d)

Planning board

39.

What form must be secured prior to starting any construction?

a)

Zoning certificate

b)

Environmental compliance

c)

Building permit

d)

Structural affidavit

40.

Total Open Space within Lot (TOSL) comprising yards, courts, gardens, lightwells, access roads, and parking spaces equals the sum of which two areas?

a)

TLA + BCR

b)

GFA + FAR

c)

Setback + RROW

d)

ISA + USA

41.

Kitchen must have a minimum area of how many square meters with least dimension specified?

a)

2.00 sqm / 1.20 m

b)

3.00 sqm / 1.50 m

c)

3.50 sqm / 1.80 m

d)

4.00 sqm / 2.00 m

42.

A mezzanine floor used for purposes other than storage must have at least two stairways to an adjacent floor if the area exceeds what threshold?

a)

200 sqm or 20 meters

b)

185 sqm or 18 meters

c)

150 sqm or 15 meters

d)

120 sqm or 12 meters

43.

A building permit shall expire if work authorized is abandoned or suspended after commencement for what period?

a)

6 months

b)

12 months

c)

4 months

d)

24 months

44.

Habitable rooms with natural ventilation must provide minimum air space per person of how much?

a)

10 cu.m

b)

12 cu.m

c)

14 cu.m

d)

16 cu.m

45.

If only two exits are required, they must be placed a distance apart of not less than what fraction of the overall diagonal?

a)

1/6

b)

1/5

c)

1/4

d)

1/3

46.

Which statement best describes Gross Floor Area in NBC context?

a)

Area bounded by internal partitions

b)

Total floor space within external walls

c)

Site area minus open spaces

d)

Usable area excluding services shafts

47.

Eaves, canopies, awnings (or media agua) over required windows shall not be less than _______ from the side and rear property lines.

a)

600 mm

b)

650 mm

c)

700 mm

d)

750 mm

48.

As per PD 1096, what is the minimum ceiling height of the first storey of a habitable room provided with artificial ventilation?

a)

2.60 m

b)

2.70 m

c)

2.75 m

d)

2.80 m

49.

Under the NBC, basic residential building in R-2 zone shall have a minimum front setback of

a)

3.00 m

b)

2.00 m

c)

4.00 m

d)

5.00 m

50.

The purpose of the NBC is to provide for all buildings and structures, a framework of standards and requirements which is the

a)

Provision

b)

Regulation

c)

Minimum

d)

Maximum

51.

Under the NBC exemption from payments of buildings permit fees shall be granted to

a)

Private Markets

b)

Public Markets

c)

Public Buildings

d)

Private Buildings

52.

Under the NBC, a building permit shall expire if work authorized is abandoned or suspended at any time after commencement or a period of

a)

60 days

b)

75 days

c)

100 days

d)

120 days