NEW
Font size
WorksheetsBldg Law
Total questions: 51
Worksheet time: 26mins
A parcel of land bounded by roads, sidewalks, alleys
Block
Plot
Parcel
Lot
If road is 9.00 m in width, what is the minimum width of the sidewalk
(on each side)?
1.50m
1.20m
1.00m
0.90m
If the width of a kitchen is 1.50 m, what is its minimum length?
2.00m
2.50m
3.00m
3.50m
Air space habitable for a classroom (cum/person)?
12
3
14
6
Allowable footprint for Group A dwellings inside lot?
50% of TLA
55% of TLA
60% of TLA
80% of TLA
Minimum door entrance width (NBCP)
70 cm
71 cm
80 cm
90 cm
Minimum door height for T&B (NBCP)
1.80 m
1.90 m
2.00 m
2.10 m
Maximum distance of PWD parking to entrance of building
30 m
45 m
60 m
90 m
Min. side aisle width (dining)
0.80 m
0.90 m
1.00 m
1.10 m
Minimum vertical clearance between the pavement or ground line and
the undersurface of any part of the marquee
2.40 m
3.00 m
4.27 m
5.00 m
Minimum horizontal clearance between the outermost edge of the
marquee and the curb line
0.30 m
0.50 m
1.00 m
1.20 m
The building permit is considered null and void.
Error in submitted plans
Non-submittal of logbook
Non-compliance with the NBCP
Construction did not commence one year after issuance of building permit.
How many days is the processing of building permits?
15 days
1 month
3 months
6 months
A wall without any openings
dead wall
blank wall
end wall
clear wall
Prime consideration in determining sidewalk width?
Accessibility
Volume of Pedestrians
Vehicles
Planting strip
What is ACP?
Air-Conditioning Pump
Architectural Code of the Philippines
Alteration and Conversion Permit
Automation Control Panel
Distance of stair handrail to wall (BP344)?
25 mm
38 mm
50 mm
58 mm
Turning space of wheelchair
1.0m x 1.0m
1.2m x 1.2m
1.5m x 1.5m
1.8m x 1.8m
Maximum slope of ramp
10%
12%
14%
15%
Maximum height of phone handset in telephone booth
0.70 m
1.10 m
1.12 m
1.20 m
Maximum height of drinking fountain
0.80 m
0.82 m
0.85 m
0.90 m
Maximum height of lavatory countertop?
0.70 m
0.80 m
0.82 m
0.85 m
Distance from back to back of chairs in rows for 46 less (FCP)
83 cm
84 cm
85 cm
86 cm
Type of door for fire protection. A fire-resistive door prescribed for
opening in fire separation walls or partitions
Exit door
Fire Escape Door
Fire Door
Rated Door
A building unsafe in case of fire because it will burn easily or because it
lacks adequate exits or fire escapes.
Dangerous building
Fire Trap
Fire Hazard
Ruinous building
A passage hall or antechamber between the outer doors and the
interior parts of a house or building.
Vestibule
Damper
Public Way
Fire Lane
Any visual or audible signal produced by a device or system to warm
the occupants of the building or fire fighting elements of the presence
or danger of fire to enable them to undertake immediate action to save
life and property and to suppress the fire.
Fire Alerting System
Fire Alarm
Smoke Detector
Annunciator
A piece of metal or an electrical conductor used to bypass a safety
device in an electrical system.
Switch
Relay
Breaker
Jumper
An integrated network of hydraulically designed piping system
installed in a building, structure or area with outlets arranged in a
systematic pattern which automatically discharges water when
activated by heat or combustion products from a fire.
Wet standpipe system
Fire Sprinkler System
Dry Standpipe System
Combination standpipe system
Who first approve a subdivision project?
HLURB
HUDCC
LGU
OBO
Usually, where is the Philippines VP (Binay, Robredo, etc.) under the
coordinated housing program of the government?
HLURB
HUDCC
HIGC
NHA
Dwelling for 3 or more families with a common passageway?
Apartment
Condominium
Single-family dwelling
Multi-family dwelling
What agency provides mass housing
HLURB
NHMFC
NHA
GSIS
Housing projects need wide tracts of land. Who shall manage/provide?
DENR
HDMF
NHA
HUDCC
Minimum door height for T&B (BP220)
180 cm
190 cm
200 cm
210 cm
Minimum open space for residential subdivisions (PD957)
10%
20%
30%
40%
Height of chair seat for comfortable dining
35 cm
40 cm
45 cm
50 cm
Minimum width of elevator door
600 mm
800 mm
1000 mm
1100 mm
Minimum thickness of column footing
200 mm
250 mm
300 mm
350 mm
Minimum depth of column footing (NGL to bottom of footing)
500 mm
600 mm
700 mm
800 mm
Min width of major road for 2.5 hectares project size (BP220)
6.50 m
8.00 m
10.00 m
12.00 m
Min width of collector road for above 30 hectares project size (BP 220)
6.5 m
8.0 m
10.0 m
12.0 m
Rooms intended for any use, not provided with artificial ventilation
system, shall be provided with a window or windows with a total free
area of openings equal to at least ______ of the floor area of the room,
provided that such opening shall be not less than _____ sq. meter.
5% / 1.20
10% / 1.00
15% / 2.40
20% / 1.50
Area per person of conference room, coffee shop, canteen, formal
dining room
0.65 sqm/person
1.40 sqm/person
0.28 sqm/person
0.46 sqm/person
Max length dead-end corridor
3.0 m
6.0 m
1.0 m
1.2 m
Air space for habitable rooms
3.0 cum/person
12.0 cum/person
14.0 cum/person
10.0 cum/person
As per NBC, what is the maximum height of riser? (mm)
150
180
200
250
As per NBC, what is the minimum depth of tread? (mm)
200
250
280
290
As per NBC, in circular staircase, what is the minimum width of tread?
(mm)
230
210
150
220
As per NBC, What is the minimum width of staircase if there are 5o or
more occupant load in a building? (mm)
750
900
1100
1200
As per NBC, what is the required parking slots for shopping center?
1 slot for every 30 sqm of shopping floor area
1 slot for every 100 sqm of shopping floor area
1 slot for every 150 sqm of shopping floor area
1 slot for every 300 sqm of shopping floor area
