wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

NBCP - Part 2

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

Which Type of Construction is being described:

Buildings of wood construction.

a)

Type II

b)

Type III

c)

Type I

d)

Type IV

e)

Type V

2.

Which Type of Construction is being described:

Buildings made with steel, iron, concrete and masonry. Non-bearing partitions can be made of wood, given that it is 1-hr fire resistive and/or treated with fire retardant.

a)

Type I

b)

Type II

c)

Type IV

d)

Type V

e)

Type III

3.

Which Type of Construction is being described:

Buildings of wood construction with protective fire-resistant materials and 1-hr fire resistive throughout. Non-bearing partitions may use wood treated with fire retardant within the framing assembly.

a)

Type II

b)

Type III

c)

Type I

d)

Type V

e)

Type IV

4.

Which Type of Construction is being described:

Buildings of masonry and wood construction and shall be 1-hr fire resistive throughout.

a)

Type II

b)

Type V

c)

Type IV

d)

Type III

e)

Type I

5.

Which Type of Construction is being described:

Buildings made with steel, iron, concrete, and masonry, including structural elements. Shall be fire-resistive throughout.

a)

Type IV

b)

Type V

c)

Type I

d)

Type IV

e)

Type III

6.

A building/structure that is located within two Fire Zones will be considered to belong to the more highly restrictive fire zone when more than _____ of its total floor area is located in such zone.

a)

1/2

b)

1/3

c)

5%

d)

15%

7.

A temporary structure may be permitted in a highly restrictive fire zone, but only for a given period of time, given that there is adequate fire suppression facilities.

a)

True

b)

False

8.

These are areas where siting of buildings/structures are permitted without fire-resistivity measures. Commonly located on countryside or rural areas where commercial/industrial establishments are sparsely constructed.

a)

Highly Fire Restrictive Zones

b)

Fire Restrictive Zones

c)

Non-Fire Restrictive Zones

9.

Areas where building with at least 2-hr fire resistivity is permitted. Usual locations on suburban areas are permitted to be built with at least 1-hr fire resistivity throughout.

a)

Highly Fire Restrictive Zones

b)

Non-Fire Restrictive Zones

c)

Fire Restrictive Zones

10.

Only Type IV and V Constructions are allowed in these areas.

a)

Fire Restrictive Zones

b)

Non-Fire Restrictive Zones

c)

Highly Fire Restrictive Zones

11.

The degree to which a material can withstand fire.

a)

Fire-Resistive Rating

b)

Fire-Resistive Time Period

12.

Length of time a material can withstand being burned which may be one-hour, two-hours, four-hours, etc.

a)

Fire-Resistive Time Period

b)

Fire-Resistive Rating

13.

What is the minimum thickness (in mm.) of a solid concrete partition with 1-hr fire resistivity?

a)

200

b)

120

c)

125

d)

100

14.

According to Rule VII of NBCP, there are ___ Groups of Occupancies subdivided into ___ Divisions.

a)

12 ; 10

b)

10 ; 5

c)

10 ; 12

d)

10 ; 25

15.

What are the 3 options for Dangerous Buildings?

a)

Repair

b)

Renovation

c)

Vacation

d)

Demolition

e)

Alteration