1.

A kind diagram that is used in designing or troubleshooting electrical installation control equipment or arrangement to simplify the tracing of the circuit.

a)

schematic diagram 

b)

pictorial drawing

c)

wiring diagram 

d)

electrical lay-out

2.

Which of the following electrical parameters apply or labelled to all kind of switches?

a)

rated current and rated voltage 

b)

rated power and rated voltage

c)

rated resistance and rated current

d)

rated power and rated current

3.

When tightening a terminal screw connection with the splice wire, the end of the splice wire should pass around the screw on the same direction as the screw is turned, so that ________________.

a)

the wire will set as the locknut

b)

any pull on the wire will tighten the screw

c)

the screw can be removed more easily

d)

the wire will not turn off

4.

One most advantage of using rubber insulation tape in splice is _________________.

a)

does not deteriorate with age 

b)

does not absorb much moisture

c)

is able to withstand high temperature 

d)

all of the above

5.

Locknut, bushing or connectors are called electrical __________.

a)

conduit 

b)

fittings 

c)

expander

d)

tighteners

6.

What is the commonly used conduit in Service Entrance?

a)

Flex Conduit

b)

RSC/IMC

c)

EMT 

d)

PVC

7.

What do you call a fitting resembling a pipe or a box with a removable cover access to electric conduit?

a)

conduit strap/clamp

b)

condulet

c)

connector

d)

locknut and bushing

8.

The box used for convenience outlet is _________.

a)

splice box

b)

full box

c)

square box

d)

utility box 

9.

A mechanical connector that is crimped unto a conductor for both splice and termination is known as _________.

a)

split bolt connector

b)

bolt connector

c)

solderless connector

d)

mechanical lug

10.

Commonly used adhesive materials for joining of PVC conduit.

a)

PVC cement

b)

PVC varnish

c)

PVC solvent

d)

PVC adhesive

11.

The size of circuit breaker to be used in 40 A motor full load current is

a)

Equal to 100AT

b)

More than 115% of the full load

c)

Less than 50AT

d)

Not less than 125% of the full load

12.

A live duplex wire can be de-energized quickly and safety by cutting ____.

a)

Across with an electrical pliers

b)

One by one using a diagonal cutter

c)

Across using a mechanical pliers

d)

One by one with a knife

13.

When measuring load current, an ammeter is connected _____.

a)

in series with the load

b)

parallel with the load

c)

across the terminals of the load

d)

from one load terminal to ground

14.

When measuring load resistance, the ohmmeter is connected____.

a)

in series with the load

b)

across the terminals of the load

c)

from one load terminal to ground

d)

parallel with the source

15.

What is the ampacity of #8.0 sq.mm. THW wires?