NEW
Font size
WorksheetsPhilippine Green Building Code
Total questions: 47
Worksheet time: 25mins
What is the "Climate Change Act of 2009"?
RA 7898
PD 7299
RA 9729
PD 1096 ANNEX B
Is the Green Building Code intended to rate buildings?
No, because the Green Building Code is a set of regulations setting minimum standards for compliance and is not intended to rate buildings The Green Building Code should not be compared to rating systems such as LEED, BERDE, and GREEEN
Yes because the green building code is certified by LEED and BERDE to Act in Accordance to the LAW.
Yes and No, there are conditions
Minimum TGFA for malls to apply Building Code
12,000 sqm
5,000 sqm
6,000 sqm
15,000 sqm
for Hospitals
10,000 sqm
1,000 sqm
5,000 sqm
12,000 sqm
For condominiums
12,000 sqm
10,000 sqm
15,000 sqm
20,000 sqm
What does BRI stand for?
Building Resistance Index
Business Related Index
Building Related Indent
Building Resistance Index
Parts of the building used bvthe occupants, owners, tenants or other building users of which the landlord retains control and is responsible to maintain in a reasonably safe condition that includes spaces such as lobby, corridor, hallway, toilet, elevator or stairway
Non-GFA areas
Utility Areas
Common Areas
Service Areas
Mixture of various organic substances that can be placed into a composition of decaying biodegradable materials which eventually turns into a nutrient- rich material, used for fertilizing soil
Organic Waste
Biodegradable Waste
Compostable waste
Food waste
An area substantially illuminated by daylight consistently receiving significant quantities of daylight during the day
Solarium
Daylight Zone
Terrace
Drying Area
Energy efficiency rating for room air conditioners that lists how many Btu per hour are used for each watt of power it draws
Energy Efficiency Ratio
Energy Efficacy Ratio
Environmental Efficiency Ratio
Earth Resistance Ratio
A horizontal surface that reflects daylight deep into a building, placed above eye-level with high-reflectance upper surfaces, which reflect daylight onto the ceiling and deeper into the space
Solar Reflector
Aluminum Foil
ACP Louver Fins (Vertical) Automated
Light Shelf
Amount of electric lighting, usually measured in watts per square foot, being used to illuminate a given space
Lighting Power Index
Lighting Power Consumption
Lighting Power Density
Lighting Power Rating
A facility designed to receive, sort, process, and store compostable and recyclable materials efficiently and in an environmentally sound manner
Material Recovery Facility
Sewage Treatment Plant
Recycling Bin
Material Recycling Facility
Resistance value or the capacity to resist heat loss or its thermal resistance
C-Value
R-Value
U-Value
None of the aforementioned
An industrial structure designed to remove biological or chemical waste products from water, thereby permitting the treated water to be used for other purposes
Material Recovery Facility (MRF)
Septic Tank with composting action
Sewage Treatment Plant (STP)
Public Sewage Disposal Plant
A measure of a material’s ability to reflect heat with white or light colors having high reflectance and dark or black surfaces with low or little reflectance thereby having higher temperatures
SRI
U-Value
R-Value
CRI
Combination of urea and formaldehyde used in some glues and adhesives, particularly in composite wood products, emitting formaldehyde at room temperature, which is a toxic and possibly carcinogenic gas
Urea Formaldehyde
Cyanide
Carbon Monoxide
Ferrous Sulfate
Employs frequency inverter technology which regulates input voltage and frequency throughout the journey, drawing much less current during acceleration and deceleration
UPS-ATS with Voltage Regulator
Variable-Voltage and Variable-Frequency
High EER Appliances
UPS with AC Voltage Regulator
The ratio of total transmitted light to total incident light with the higher value allowing more incident light to pass through the glazing
C-Value
U-Value
Visible Transmittance
R-Value
Organic chemicals with have a high vapor pressure at ordinary room temperature that are dangerous to human health or cause harm to the environment
Formaldehyde Organic Compounds
Volatile Organic Compounds
Methane Organic Compounds
VOP
Ratio of the total area of a building facade, which is occupied by windows (glass area and frame)
WWI
WWR
WVR
WFR
Which material transmits more heat?
Wood
Concrete
Glass
Drywall (Gypsum)
heat transmitted through glass divided by radiation incident on glass
SHGC
SGHC
SSCGH
HSGC
Composting by Earthworms is called as
Worm Composting
Bio Composting
Natural Composting
Vermicomposting
LCA stands for
Life Cycle Analysis
Life Cost Analysis
Lead Cost Assesment
None of the above
Minimum air space for Workshops, Factories, and Offices is ___ cubic meters of air space per person
1.00
10.00
12.00
14.00
Maximum Allowable PSO (percentage site occupany) for Institutional with firewall
60
50
55
70
Attempts to safeguard air, water, and earth by
choosing eco-friendly building materials and
construction practices.
Tropical
Design
Sustainable
Design
Green
Architecture
Bio-Climatic
Design
Door Leaf Width. No leaf of an exit door shall exceed ___meters in width
1.00m
1.10m
1.20m
1.50m
The term usually applies to the surfaces of terrestrial and glaciated environments, but it could also pertain to the surfaces of oceans and other bodies of water.
Topography
Snow Cap
Microclimate
Marine
A building materials which is one of the poorest conductor of heat.
Wood
Concrete
Sun Dried Bricks
Bamboo
An independent art gallery run by the various artist to provide spaces to showcase Arts.
Tropical Baroque
Passion of Christ
White Cube
Private Gallery
Artist Run
a technique that efficiently brings light into your home using exterior glazing (windows, skylights, etc.), thereby reducing artificial lighting requirements and saving energy.
Skylight
Passive Lighting
Soloar Radiation
Day Lighting
the process of supplying air to and removing air from an indoor space without using mechanical systems.
Active Cooling
Natural Ventilation
Cross Ventilation
Exhaust Ventilation
Integrates architecture and sculpture and is often embellished with rosettes, scrolls, pediments and Solomonic columns which may be gilded or polychromed
Baroque
Santos
Via Crucis
Retablo
the ability of a material to absorb and stored heat energy.
Radiation
Heat Gain
Thermal Mass
Green House
BERDE has an Innovation category, and LEED does not.
TRUE
FALSE
What specific type of architecture did the Spanish colonizers apply to the designs and structures in the country?
Italian
European
Antillian
An Jeeran
MORE WALLS ON HOUSES NOT ONLY ALLOW AIR TO CIRCULATE FREELY, IT ALSO MAKES THE ROOM LOOK BIG AND SPACIOUS.
TRUE
FALSE
Alaska, USA
Tropical climates
Dry climates
Temperate climates
Continental climates
Any climatic condition in a relatively small area, within a few metres or less above and below the Earth’s surface and within canopies of vegetation.
Macroclimate
Microclimate
Weather
Climate
the ability to be maintained at a certain rate or level.
meeting our present needs, without compromising the ability
of future generations to meet their own needs.
Renewable
Design
Green
Design
Sustainable
Design
Tropical
Design
Which statement accurately describes LEED?
Program of the Environmental Protection Agency (EPA) and the Department of Energy (DOE). Its goal is to help consumers, businesses, and industry save money and protect the environment through the adoption of energy-efficient products and practices.
Program—An independent certification program developed by the U.S. Green Building Council that provides rating systems for the design, construction, and ongoing operation and maintenance of high performance green buildings
Program - accreditations for environmental quality in one or two family dwellings with or with out wood stoves
The design of products and environments to be usable by all people, to the greatest extent possible, without the need for adaptation or specialized design.”
administration of title 505 Federal regulation 1997
LEED Accreditations
Universal Design
Wood Stove
Air Conditioning Accounts for more than ____% of total electricity costs in a centrally air conditioned building.
40%
20%
70%
50%
One of the most important aspects of the design of a Green Building is the implementation of low impact, renewable and sustainable energy sources. Which of the following is not an ideal energy source for a Green Building?
Natural gas
Solar
Wind
Biomass
Green belt prevents construction in certain areas.
True
False