NEW
Font size
WorksheetsChapter 6 Hydraulic
Total questions: 40
Worksheet time: 10hrs 0mins
In a directional control valve, port receives fluid flow from the pump, while port returns fluid flow to the reservoir.
A; B
B; A
P; T
T; P
A __ center position directional control valve allows a hydraulic system to operate with more than one actuator and with each actuator operating independently of the others.
closed
float
open
tandem
A __ is an internal component of a directional control valve that is used to control fluid flow and to connect internal passages and ports.
actuator
piston
plunger
spool
There are __ different subplate designs
two
seven
nine
ten
A __ center position directional control valve is used to hold the piston in a cylinder in the desired position while allowing fluid flow to be directed back to the reservoir without the need to activate a relief valve.
closed
float
open
tandem
__ mounting is a method that uses tubing or threaded pipes that connect directly to a directional control valve.
In-line
Manifold subplate
Pipe
Valve
A directional control valve __ is a mechanism that is used to move the position of the spool in a directional control valve.
actuator
handle
positioner
slide
Solenoids alone are not strong enough to move a directional control valve spool when the fluid flow is greater than __ gpm.
20
25
35
50
In a directional control valve schematic symbol __ the position boxes depict the direction of fluid flow for each spool position.
external arrows outside
internal arrows inside
diagonal lines outside
T-shaped symbols
A hydraulic system that does not have a variable displacement, pressure compensated pump typically uses a(n)_____ centered or _____- center position directional control valve so that the hydraulic fluid can be returned to the reservoir
closed; float
float, tandem
open; closed
open, tandem
__ pressure is the amount of pressure required to slightly unseat a ball or poppet and start to allow fluid flow through a check valve.
Cracking
Operating
Pilot
Poppet
A(n) __ is a schematic representation of the direction in which a spool forces fluid to flow.
actuator
position
valve port
way
__ pressure is initiated when the fluid pressure in a fluid power system shifts the spool into the desired position.
Pilot
PLC
Solenoid
Spring
A __ check valve allows fluid flow in one direction and restricts fluid flow in the opposite direction until it receives a pressure signal through a pilot line applied to the port against the piston.
direct-acting
pilot-to-close
pilot-to-open
solenoid-actuated
The advantage of a three position, four way directional control valve is that it has different center positions that can preform different operations.
three; three
three; four
four; three
four; four
Two-position, two-way directional control valves can turn on and off separate components of systems that are powered by the same hydraulic power unit.
True
False
Most directional control valves used in industrial applications have two, three, or four positions, but some can have five or six positions.
True
False
Every manufacturer has a different coding system used for ordering their directional control valves.
True
False
Three-position, four-way directional control valves can only control one direction of fluid flow at a time.
True
False
Internal arrows on a hydraulic schematic diagram can be either colored solid or outlined.
True
False
On a three-position directional control valve, both sides of the spool have springs to center the spool for normal condition.
True
False
An AND logic valve allows fluid flow out of the valve when pressure is present on input 1 and input 2.
True
False
A shuttle valve is also known as an AND logic valve.
True
False
Right angle check valves are installed mainly in hydraulic systems, rather than pneumatic systems.
True
False
A shuttle valve operates differently than an OR logic valve.
True
False
Pilot-pressure actuators are used when electronic control of a hydraulic system is desired.
True
False
On schematic diagrams, pilot lines are indicated by dotted lines.
True
False
Open-center position directional control valves are typically used in applications where there is only one cylinder in the hydraulic system.
True
False
Pilot pressure does not require electrical, mechanical, or manual actuation.
True
False
A position is the number of piping ports in a directional control valve.
True
False
Solenoid-actuated directional control valves are always double-solenoid actuated.
True
False
A shuttle valve is a type of logic valve.
True
False
Newly installed directional control valves typically have a schematic symbol printed or embossed on the valve body.
True
False
The pressure point at which an automatic detent releases can be fixed or variable.
True
False
Directional control valve actuators can be automated or manual but never a combination of both.
True
False
The spring pressure of the biasing spring in a direct-acting check valve is adjustable.
True
False
When a directional control valve is in the closed-center or tandem-center position, the piston in a hydraulic cylinder can move.
True
False
Two-position, two-way directional control valves are always normally closed (NC).
True
False
Two- and three-way directional control valves only control one direction of fluid flow at a time.
True
False
Manifold subplates reduce the amount of space and piping that a hydraulic system requires.
True
False