WorksheetsBUILDING 121 - 160
Total questions: 40
Worksheet time: 20mins
Which one of the following types of safety glazing materials shall not be solely identified by a certificate or affidavit?
laminated glass
tempered glass
wired glass
plastic glazing
Which one of the following fire-rated glazing markings is required for a sidelight adjacent to a 1-hour corridor fire door assembly?
D-H-45
D-H-O-H-20
D-H-O-H-45
W-60
When a covered mall building exceeds ____________ square feet an emergency voice/alarm communication system shall be provided.
50,000
44 inches
72 inches
96 inches
Where a smoke control system is required and the exhaust method is utilized, what is the minimum height at which the smoke layer interfaced must be maintained above the means of egress walking surface?
6 feet, 0 inches
7 feet, 6 inches
7 feet, 0 inches
6 feet, 8 inches
In a fully sprinklered Type IIB building where the fire separation distance is 12 feet, the maximum allowable area of protected exterior wall openings is _______________.
15 percent
25 percent
45 percent
60 percent
Penetrations in _______________ shall be tested for air leakage in accordance with the requirements of UL 1479.
smoke partitions
smoke barriers
fire barriers
fire walls
In a nonsprinklered building, any single opening in a fire barrier is limited to a maximum area of _______________ square feet.
20
100
120
156
In a Group I-2 occupancy where a pair of opposite-swinging doors without a center mullion is installed in a smoke barrier across a corridor, the doors are permitted maximum undercuts of _______________ inch.
1/4
3/8
1/2
3/4
Unless cellulosic fiber loose-fill insulation is provided, insulation concealed within buildings shall have a maximum flame spread index of __________.
450
125
25
15
Limited area sprinkler systems are only permitted to protect areas classified as __________.
Light Hazard
Light Hazard or Ordinary Hazard Group 1
Ordinary Hazard Group 1 or 2
Light Hazard, Ordinary Hazard Group 1 or Ordinary Hazard Group 2
A roof recover is not permitted when the existing roof is already covered with ___ or more applications.
1
2
4
3
Unless otherwise noted, the fire-resistance rating of a smoke barrier shall be rated for no less than ___ hour(s).
2
1/2
1
4
When depositing concrete for a foundation pour, it shall be protected from freezing for a period of no less than ___ days thereafter.
7
21
2
5
Surfaced dried structural floor sheathing that spans 24 inches on center shall have a minimum thickness of ___ inches when placed perpendicular to supports.
5/8
1/2
3/4
23/32
Chimney walls constructed of solid masonry units shall have a nominal wall thickness of no less than ___ inches.
6
4
8
12
Glazing in fire window assemblies shall have a minimum rating of ____ minutes when located in a 1 hour rated exterior wall assembly.
90
20
Not Permitted
45
- True or False. EIFS applications installed over masonry walls require special inspection.
True
False
Fire exit hardware is also known as ______ when listed for use on fire door assemblies.
None of the above
Panic hardware
Exit hardware
Fire hardware
The ends of floor joists bearing on masonry shall not have less than ___ inches bearing.
1
2
3
1 ½
In conventional light-frame construction, wood studs within a nonbearing partition are permitted to be bored provided that the diameter of the hole is not more than ______.
60 percent of the stud width
5/8 inch
25 percent of the stud width
40 percent of the stud width
Polyethylene vapor retarders placed under concrete floor slabs shall have joints lapped not less than ____ inches.
6
4
8
2
A clear passageway of no less than ___ feet shall be provided between cabinet counters and appliances within a kitchen.
6
3
4
5
Cap flashing for asphalt shingles shall have a minimum nominal thickness of ____ inch.
0.019
0.105
0.125
0.250
Accessory to a Group R-3 occupancy, prefabricated above ground swimming pools less than ___ inches deep and no greater than ______ gallons is exempt from a permit.
24 , 5,000
24 , 8,000
18 , 8,000
18 , 5,000
Energy efficiency inspections shall include which of the following?
All of the above
HVAC equipment efficiency
Duct System R-value
Fenestration U-value
Wood veneers installed on exterior walls of buildings of Type III construction shall not exceed ___ feet in height above grade.
20
80
60
40
The specified compressive strength for structural concrete in foundation walls of a Group R-3 occupancy building not more than three stories above grade plane shall not be less than ____.
2000 psi
3000 psi
2500 psi
4000 psi
True or False. Framing inspections shall be made before the approval of rough plumbing inspection.
False
True
Fasteners for asphalt roof shingles shall penetrate into the roof sheathing a minimum of ___ inch.
1/4
1
3/8
3/4
The walls of shower compartments shall have a smooth nonabsorbent surface that extends to a height not less than ___ inches above the drain.
80
72
64
70
Wood framing members resting on or in contact with exterior foundations walls are not required to be of preservative-treated wood when located ___ inches or more from the exposed earth.
8
4
12
6
Fiberboard siding must have a minimum thickness of ____ inches in order to be acceptable as an approved weather covering for exterior walls.
0.25
0.50
0.75
0.33
Which occupancy group is a Physician's office classified as?
B
1-1
A-3
1-2
For what period of time must cement plaster coats be protected from freezing weather after it has been set?
Not less than 18 hours
Not less than 12 hours
Not less than 36 Hours
Not less than 24 hours
Exterior walls that have a fire-resistance rating and a fire separation distance of less than 10 feet shall be rated for exposure to fire from _______.
Inside Only
Exterior Side only
Both Sides
Not required to be rated
A plain masonry foundation wall 9 feet in height subject to a maximum unbalanced backfill height of 4 feet shall have a minimum required nominal wall thickness of ____ inches when the design lateral soil load is 60 psf per foot of depth.
10
8
6
12
When an emergency repair needs to take place, the permit application shall be submitted _________.
Anytime after the repair is made
Prior to the repair
The same day
The next working business day
Type PBU particleboard floor underlayment shall not be less than ____ inch thick.
1/8
1/2
1/4
3/4
A fire door shall be rated for a minimum of ___ minutes when located within a 3 hour exterior wall assembly.
90
45
20
60
Unless otherwise noted, the fire-resistance rating of a fire partitions shall be rated for no less than ___ hour(s).
1/2
1
2
4