RAC Basic refrigeration & refrigerants QUIZ

Total questions: 27

Worksheet time: 26mins

Name
Class
Date
1.

A reversible Carnot cycle used for refrigeration

comprises

a)

Two isentropic and two adiabatic processes

b)

Two isentropic and two constant volume processes

c)

Two isentropic and two constant pressure process

d)

Two isentropic and two isothermal processes

2.

The heat removing capacity of one tone of refrigeration is equal to?

a)

210 Watt

b)

210 kJ/hour

c)

3.5 kJ/hour

d)

3.5 kW

3.

The COP of a refrigerator is 4. What will be the COP of a heat pump if it is working between same source and sink temperature ?

a)

2

b)

3

c)

4

d)

5

4.

One tonne of refrigeration is equal to

a)

21 KJ/min

b)

210 KJ/min

c)

420 KJ/min

d)

620 KJ/min

5.

One tonne of refrigerating machine means that,

a)

One tonne is the total mass of the machine

b)

One tonne of refrigerant is used

c)

One tonne of water can be converted into ice.

d)

One tonne of ice when melts from and at 0oC in 24 hours, the refrigerating effect produced is equivalent to 210 KJ/min

6.

In a refrigerating machine, heat rejected is ............ heat absorbed.

a)

Equal to

b)

Less than

c)

Greater than

d)

partially less than

7.

The C.O.P. of a heat pump working on a reversed Carnot cycle is ( T₂- high temperature, T₁ - Low Temperature)

a)

(A) T₁/(T₂ - T₁)

b)

(B) (T₂ - T₁)/T₁

c)

(C) (T₁ - T₂)/T₁

d)

(D) T₂/(T₂ - T₁)

8.

If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of -23°C, then the Carnot COP will be

a)

(A) 0.2

b)

(B) 1.2

c)

(C) 5

d)

(D) 6

9.

A reversible engine has ideal thermal efficiency of 30%. When it is used as a refrigerating machine with all other conditions unchanged, the coefficient of performance will be

a)

(A) 1.33

b)

(B) 2.33

c)

(C) 3.33

d)

(D) 4.33

10.

ODP stands for

a)

Outdoor Dangerous Pollution

b)

Over Demanding Protocol

c)

Ozone Depletion Protocol

d)

Ozone Depletion Potential

11.

Which of the following refrigerants are phased-out due to Montreal protocol on ozone layer depletion-

a)

R11

b)

R21

c)

R12

d)

R32

12.

TEWI stands for

a)

Total Energy Work Interaction

b)

Total Equivalent Warming Index

c)

Total Equivalent Work Index

d)

Transfer of Energy With Intensity

13.

A refrigerant should have

a)

High ODP

b)

High GWP

c)

Low ODP

d)

Low GWP

14.

The chemical formula of refrigerant R11 is:

a)

CCl3F

b)

CClF3

c)

CClHF

d)

CHF

15.

The chemical formula of R141 is:

a)

C2H3ClF3

b)

C2H2Cl3F

c)

C2H3Cl2F

d)

C2H2ClF3

16.

Secondary refrigerants are also called as

a)

Coolers

b)

Brines

c)

Wines

d)

Synthetic Solutions

17.

Azeotropic mixtures are

a)

100 series

b)

500 series

c)

400 series

d)

1000 series

18.

Inorganic compounds are

a)

500 series

b)

200 series

c)

700 series

d)

1000 series

19.

The reference gas used in calculation of ODP is:

a)

CO2

b)

CFC

c)

NO2

d)

Hydrocarbons

20.

The reference gas used in calculation of GWP is:

a)

CFC

b)

Bromine

c)

CO2

d)

NH3

21.

R717 is refrigerant name for

a)

Water

b)

Carbon dioxide

c)

Ammonia

d)

Air

22.

For the refrigernat R134a, 'a' stands for:

a)

isomers

b)

Epimers

c)

isotopes

d)

Derivation

23.

Which of the following refrigerants are suggested as replacements for R22 in large air conditioning and cold storage systems?

a)

R134a

b)

R21

c)

R410A

d)

R407C

24.

Which of the following statements is TRUE?

a)

Evaporation process is non-isothermal for zeotropic mixtures

b)

Evaporation process is non-isothermal for azeotropic mixtures

c)

Composition of azeotropic mixture changes in the event of a leak

d)

Composition of zeotropic mixture changes in the event of a leak

25.

Which of the following statements are TRUE?

a)

The suction pressure of a refrigerant should be as high as possible

b)

The suction pressure of a refrigerant should be as low as possible

c)

The discharge pressure of a refrigerant should be as high as possible

d)

The discharge pressure of a refrigerant should be as low as possible

26.

Which of the following statements are TRUE?

a)

A primary refrigerant does not undergo phase change in a refrigeration cycle

b)

A secondary refrigerant does not undergo phase change in a refrigeration cycle

c)

The freezing point of a brine is generally lower than the freezing point of its constituents

d)

The freezing point of a brine is generally higher than the freezing point of its constituents

27.

According to ASHRAE, Refrigerants belonging to Group A1 are__________ , while refrigerants belonging to Group B3 are ___________

a)

most hazardous, least hazardous

b)

least hazardous, most hazardous