Given 27 seats in an assembly area how many accessible wheelchair spaces are required?
2
5
4
1
What is the minimum width for an exit stairway in a parking garage?
42 in
32 in
24 in
36 in
If a building official finds a structure to be unsafe what shall be done?
A notice to either make safe or demolish shall be issued
A notice to abandon shall be issued
The building official shall have the structure demolished
The building official shall give notice of impending legal action
Other than exceptions until what height are projections into the public right of way prohibited?
10 ft
20 ft
8 ft
15 ft
All residential group occupancies must be equipped with automatic sprinkler systems and what else?
Smoke alarms
Smoke suppression system
Smoke evacuation system
Smoke barriers
What is the maximum spacing of 2x4 studs in a bearing wall supporting roof and ceiling only?
16 in
32 in
24 in
20 in
High-rise buildings shall have what kind of additional power provided?
Emergency and standby power
Emergency power
In a public parking garage where must vehicle barriers be placed?
2 ft from changes in elevation
4 ft from changes in elevation
Ends of elevations
End of drive lanes
Fire retardant wood has a flame spread index of what?
25
75
250
50
What type of construction has exterior walls and interior elements of noncombustible materials?
Type III
Type IV
Type F
Type V
Open parking garages must comply with which section?
406.5
405.3.2
406.9.2
409.2.5
What is the maximum area of a structural piece of exterior glass veneer?
12 ft
20 ft
10 ft
9 ft
Where shall the roof and floor design loads be posted?
On a singular load bearing column
The foundation of the building
Each story of the building
On the lowest story of the building
How long is a permit valid after issuance if work is not commenced immediately?
90 Days
75 Days
365 Days
180 Days
Where is fastening required on double studs?
Face nail
Toe nail
Base nail
Top nail
Covered and closed mall buildings shall be equipped with what?
Chemical standpipe system
Wet standpipe system
Dry standpipe system
Oversized standpipe system
What kind of department does not need a permit to install generation or metering equipment?
Rail road
Commercial development corporation
Public Service Agency
Homeowners association
What is the most lenient type of construction?
Type V
Type I
Type II
Type III
In the verification and inspection of cast in place deep foundation elements what is the second inspection that is required?
Verification of placement
Verification of strength
Verification of steel
Verification of location and plumbness
An interior finish in a sprinklered Group F occupancy shall be of what class in an exit stairway?
B
C
F
A
Thresholds for sliding doors serving dwelling units shall not exceed how much?
4/16 in
1 in
1/2 in
3/4 in
Who determines the additional fee value for work that is commenced before permit issuance?
The plans examiner through valuation
The permit technician
The building inspector during construction
The building official through a valuation
What is an example of Group I-3?
Jails
Churches
Halfway houses
Colleges
What is the fourth inspection required?
Placement of concrete inspection
Roofing inspection
Frame inspection
Cast in place foundation elements inspection
What is the range in which handrails shall be located in?
36 in by 48 in
34 in by 38 in
24 in by 24 in
36 in by 36 in
A masonry wall that is 9-4 ft high with 5 in of backfill shall have what size # bar at 30 psf?
6
4
8
2
In a Group F-1 occupancy how many water fountains shall be present?
1 per 400
1 per 250
1 per 100
1 per 300
Flashing of metal shall not be less than what thickness?
.020 in
.125 in
.255 in
.019 in
What is the minimum width of shallow foundation footings below undisturbed ground surface?
6 in
25 in
12 in
20 in
Other than doors to a hoist way, elevator machine room, machinery space, control rooms or control spaces within an elevator lobby, doors leading into elevator lobby enclosures shall be provided with what fire rating?
1/2 hr
3/4 hr
2/3 hr
1/3 hr
Aggregate accessory occupancies shall not occupy more than how much of the building area of the story which they are located on?
25 percent
10 percent
15 percent
50 percent
What is one of the criteria that shall determine if soil is expansive?
Expansion index greater than 100 in accordance with ASTM D4829
Expansion index greater than 40 in accordance with ASTM D4829
Expansion index greater than 50 in accordance with ASTM D4829
Índice de expansão maior que 20 de acordo com a norma ASTM D4829
Bearing exterior walls in type II-B construction shall have a fire resistance rating of what?
0
4
2
1
How many days may a building official grant additional period of extension?
180 Days
75 Days
360 Days
90 Days
May a building official authorizing in writing a period of extension not more than?
180 Days
75 Days
360 Days
90 Days
One story buildings of no more than one story above grade plane of Group B-F-M or S with public ways not less than 60 ft in width shall not be limited in space given what?
Smoke control system
Standpipe system
Automatic sprinkler system
Automatic smoke suppression system
What shall be the clear width of an accessible means of egress stairway between handrails in an unsprinklered building?
24 in
48 in
36 in
52 in
An accessible stairway must have a minimum of ________width?
24 in
48 in
36 in
52 in
Deep foundation bracing elements shall be subject to the approval of who?
who prepar it ? Registered design professional
Registered design professional
Contractor
Building official
City engineering department
Incidental use buildings shall not take up more than how much of the building area?
15 percent
10 percent
25 percent
35 percent
When is a building official allowed to enter a structure?
When presenting a stop work order
When authorized by the owner
When reasonable cause for intentional code violation
When a building has been deemed unsafe
An elevator shall transfer to standby power within how much time?
20 seconds
Immediately
120 seconds
60 seconds
Concrete foundation wall concrete cover reinforcement measured from the inside face of the wall shall not be less than how much?
3/4 in
1/2 in
3/8 in
1 in
Class II standpipe hose connections shall be located where they have what kind of access?
Confirmed Access
Ready Access
Approved Access
Registered Access
Flood loads documentation shall be prepared and sealed by who?
Registered design professional
Building department
Building official
City engineering department
Hearths shall have a minimum thickness of what?
2 in
8 in
12 in
4 in