WorksheetsECH4201 Topic 7 (Purification Technique- Chromatography)
Total questions: 50
Worksheet time: 32mins
Chromatography can be used for separation in lab and industry
True
False
Which one is stationary phase?
Methanol
Silica gel
Hexane
Classification of chromatography based of mobile phase
Liquid chromatography
Gas chromatography
Solid Chromatography
The following is something we need to consider for choosing mobile phase except
Polarity interaction
Eluotropic series
Polarity prediction of mixed solvent
Stationary phase
Which one is industry commonly using chromatography?
Pharmaceutical
Food
Construction
Retention factor can be used for
Indentifcation unknown compound
Polarity compound
None of above
Ion-Exchange chromatography:
separate and analyze compounds that can be vaporized without decomposition
Also known as Liquid-Solid Chromatography
Materials used are either cation or anion resins
Separation based on partition coefficient between 2 immiscible liquids
What type of chromatography is depicted by the illustration?
Gel Filtration Chromatography
Column Chromatography
HPLC
Thin Layer Chromatography
Which of the following methods could be used to check the molecular weight of your purified protein?
SDS-PAGE
Mass Spectrometry
Analytical SEC
All of above
To elute target proteins from an affinity chromatography matrix, which of the following conditions would be the most appropriate?
Low salt concentrations
High salt concentrations
Adding a soluble ligand which competes with the affinity tagged protein for binding to the column
Just keep washing buffer through the column, isocratic elution
What is the starting point for selection of a suitable IEX matrix for purification of a recombinant protein?
Prediction of isoelectric point (pI) from the amino acid sequence
Test protein binding to an IEX matrix at a range of pHs and salt concentrations
Test protein binding to a selection of anion and cation exchange matrices
Pass your sample through a preparative column and elute with a salt gradient
You find that your protein sample loses activity during storage. What can you do about this?
Add an additional purification step
Use a protease inhibitor during purification steps
Perform each step as quickly as possible, in a cold-room
All of the above
Hydrophobic amino acids are ones which _______ water.
are attracted to
are repelled by
react with
melt in
What is chromatography?
A way to see pretty colors
A laboratory technique used to separate a mixture.
A form of distillation
I paper chromatoraphy
II TLC
III HPLC
IV GC
Which technique is commonly used to analyze metal ions and organic compounds in solutions?
Liquid Chromatography
Gas Chromatography
Thin-layer Chromatography
Paper Chromatography
Using a salt gradient is most commonly used to elute proteins in which chromatography method?
HPLC
affinity
Ion Exchange
size exclusion
Which chromatography method relies on specific binding between a protein and a complimentary substrate/ligand?
HPLC
affinity
ion exchange
size exclusion
Which method would pass a liquid solvent through the stationary phase at high pressure?
HPLC
affinity
ion exchange
size exclusion
In size exclusion chromatography, why do large proteins elute first?
they travel through the void of stationary phase matrix so pass through the column quicker
they enter the porous matrix of the stationary phase so pass thorugh column quicker
small particles bind to the porous matrix of the stationary phase meaning large will elute first
they don't elute firts, the smaller proteins do.
A cation exchange column has which kind of charge?
postive
negative
An anion exchange column carries what kind of charge?
positive
negative
In cationic exchange which ion from the salt wash would outcompete the proteins bound to the column, causing them to elute
Na+
Cl-
Which polymer is often used for matrix materials in Affinity chromatography
Agarose
cellulose
dextrose
all of the above
To elute target proteins from an affinity chromatography matrix, which of the following elution methods is LEAST appropriate?
changing pH
Increasing ionic strength (e.g increasing NaCl gradient)
Using a competitive ligand (e.g competitive inhibitor)
isocratic elution (continual application of wash buffer)
Which of these techniques is often considered a suitable "polishing" step in a protein purification strategy?
Affinity chromatography (AC)
Ion-exchange chromatography (IEX)
Hydrophobic interaction chromatography (HIC)
Size-exclusion chromatography (SEC)
What are the two(2) important phases of chromatography ?
mobile and inert phase
flexible and immobile phase
mobile and stationary phase
stationary and indestructible phase
Fruit drink colored orange contains a dissolved of red and yellow coloring coloring agents. One of these coloring agents is suspect of being illegal. Which method could be used to show the presence of this illegal coloring agent?
Filtration
Simple distillation
Evaporation
Chromatography
Ion-Exchange chromatography:
separate and analyze compounds that can be vaporized without decomposition
Also known as Liquid-Solid Chromatography
Materials used are either cation or anion resins
Separation based on partition coefficient between 2 immiscible liquids
Stationary Phase
System modules
Column
Solvents
Detector
Resolution
Capacity to separate an certain quantity of analyte
Selectivity of stationary phase towards a specific analyte
Efficiency of chromatography to separate compounds as quick as possible
Ability to identify individual analyte
Chromatogram
A picture of lights
Method development
A set of properties for a run
A pattern of separation
Baseline
Starting spectra of an analysis
Starting datapoints of an analysis
The standard timepoint of an analysis
The standard (sample) of an analysis
Void volume
Empty space in the galaxy
Empty space in the column
Empty space in the solvents
Empty space throughout the chromatography
Elution
Analyte injection time
Analyte retention time
Analyte exit time
Analyte preparation time
Retention time
Time spent between injection and column
Time spent inside column only
Time spent between column and detector
Time spent from injection until detection
Retardation value (Rf) is determined by
R=YX
x = weight of molecule;
y= size of molecule
x= length of molecule;
y=weight of sample
x= distance travelled by substance;
y= distance travelled by solvent
x= concentration of sample;
y= concentration of solvent
What is Eluent?
Is a Liquid solution
Is a Liquid Solution that is a result from Elution
It is a solvent used for separation of absorbed material from stationary phase
None of the above