1.

What kind of fittings should be used to avoid contamination?

a)

WRAS approved fittings

b)

Corrosion resistant fittings

c)

Contamination resistant fittings

d)

Compression fittings

2.

Which two tests are key for a cold water system?

a)

Pressure

b)

Flow rate

c)

Temperature gain

d)

pH levels

e)

Bacterial growth levels

3.

Select two advantages of an indirect system.

a)

Unaffected by peak demand.

b)

Potable water at every draw off point.

c)

Stored supply of water should interruption occur to the main.

d)

No concerns about storage cisterns in loft.

e)

Good pressure at all outlets.

4.

Identify this FOV.

a)

BS 1212 Part 2 float operated valve

b)

BS 1212 Part 1 float operated valve

c)

BS1010 Part 2 float operated valve

d)

BS 1010 Part 1 float operated valve

5.

Type the number. Fluid category _ represents a significant health risk.

(a)  

6.

What prevention of backflow must be maintained on a basin?

a)

AUK 1 air gap

b)

AUK 2 air gap

c)

AUK 3 air gap

d)

AG air gap

7.

Identify this FOV.

a)

BS 1212 Part 4 float operated valve

b)

BS 1212 Part 1 float operated valve

c)

BS 1212 Part 2 float operated valve

d)

BS 1212 Part 3 float operated valve

8.

What are the three things that insulation is trying to prevent?

a)

Heat gain

b)

Heat loss

c)

Freezing

d)

Heat impact

e)

Heat

9.

The cold feed, feeds all of the outlets on an indirect system. True or false?

a)

False

b)

True

10.

Type your answer. A (a)   must be used as an isolation valve on the cold distribution pipe, as it will not restrict the flow of water when open.

11.

Who has responsibility for repairing and maintaining the Communication pipe?

a)

Local authority

b)

Property owner

c)

Government

d)

Water undertaker

12.

WRAS stands for?

a)

Water Regulations Application Service

b)

Water Regulations Advisory Service

c)

Water Regulations Advisory Scheme

d)

Water Regulations Arbitration Site

13.

What is a ferrule?

a)

An iron measuring device

b)

A fitting used to connect to a water main

c)

A metal containing iron

14.

Who has responsibility for repairing and maintaining the Service pipe?

a)

Local authority

b)

Property owner

c)

Water undertaker

d)

Government

15.

At what temperature does temporary hard water begin to form limescale?

a)

55°C

b)

65°C

c)

85°C

d)

100°C

16.

The chemical compound for calcium carbonate is CaCO3.

a)

True

b)

False

17.

Which type of water is of an acidic nature and causes problems to plumbing systems through electrolytic corrosion?

a)

Permanent hard water

b)

Temporary hard water

c)

Neutral water

d)

Soft water

18.

Which method is used to treat very hard water in plumbing systems?

a)

Galvanic cell

b)

Base exchange water softener

c)

Chemical dosing

d)

Electromagnetic waves

19.

Which type of water filters through limestone and chalk?

a)

Very soft water

b)

Soft water

c)

Permanent hard water

d)

Temporary hard water

20.

When installing an incoming mains, the pipe should be laid between:

a)

500mm and 1200mm

b)

800mm and 1500mm

c)

750mm and 1350mm

d)

1000mm and 2000mm

21.

What colour is MDPE?

a)

Black

b)

Blue

c)

Red

d)

Yellow

22.

What is the minimum size pipe modern properties are supplied with?

a)

15mm

b)

22mm

c)

25mm

d)

28mm

23.

Due to MDPE degrading in sunlight, what is the maximum permitted length you can install above the finish floor level?

a)

400mm

b)

275mm

c)

200mm

d)

150mm

24.

In accordance with the Water Regulations, where should the stop valve be located?

a)

Inside the building, below floor level, as close as possible to the door

b)

Inside the airing cupboard, as close as possible to the door

c)

Outside the building, as close as possible to the property boundary

d)

Inside the building, above floor level, as close as possible to the point of entry

25.

Where must you install drain-offs in a plumbing system?

a)

At every low point in the system

b)

At every high point in the system

c)

In areas out of sight to the homeowner

d)

Just at the point of entry to the property

26.

Select all correct options.

Grey water recycling is used on which appliances?

a)

WC cisterns

b)

Washing machines

c)

Dishwashers

d)

Basins

27.

Grey water is considered as wholesome water.

a)

True

b)

False

28.
Question Image

Match the following descriptions to the correct fluid category

a)

These changes are aesthetic only and do not constitute

a health risk. Typical situations where this may occur in

domestic properties are:

● water heated in a hot water secondary system

● mixed fluid categories 1 and 2 water discharged

from combination taps or showers

1.

Fluid category 2

b)

Typical situations are:

● in houses, apartments and other domestic dwellings:

● water in the primary circuits of heating systems

whether chemicals have been administered or

not

● water in washbasins, baths and shower trays

● clothes and dishwashing machines

● home dialysis machines

2.

Fluid category 3

c)

Typical situations are:

● fire sprinkler systems using anti-freeze

chemicals

● house gardens:

● mini irrigation systems without fertiliser or

insecticides, including pop-up sprinkler systems

and permeable hoses :

● commercial dishwashers

● refrigerating equipment

3.

Fluid category 4

d)

Typical situations are:

● industrial cisterns and tanks

● hose union bib taps in a non-domestic installation

● sink, WC pans, urinals and bidets

● permeable pipes in any non-domestic garden

whether laid at or below ground level

● grey water recycling systems

4.

Fluid category 5

29.

Which one of the following

connections to the CWSC must be

screened?

a)

Cold supply pipe

b)

Cold feed pipe

c)

Warning pipe

d)

Cold distribution pipe.

30.

The warning pipe from a cold water storage cistern must be fitted ?

a)

A. Lower than the float valve

b)

B. Higher than the float valve

c)

C. On the opposite side of the cistern

to the float valve

d)

D. Level with the float valve

31.

A plastic Domestic Cold Water Storage Cistern should be ?

a)

A. Supported with batons under the base

b)

B. Supported over the entire area of the

base with hardboard

c)

C. Supported over the entire area of the

base with chipboard

d)

D. Supported over the entire area of the

base with floor boarding or ply

32.

It is important that flux should be removed from copper tube after the joints have been soldered to help prevent ?

a)

A. Water looking bad

b)

B. Minor staining of the tube

c)

C. Corrosion of the copper tube

d)

D. Odour in the water

33.

The pressure from the bath shower taps in a bungalow is very low when the shower is used. What would be the best solution ?

a)

A. Increase the hot & cold pipe sizes

b)

B. Raise the storage cistern

c)

C. Lower the storage cistern

d)

D. Fit pressure boosting valves

34.

Type your answer. What is the name of the process when water molecules become excited and enter the atmosphere?

(a)  

35.

When did the current UK Water Regulations come into force?

a)

1991

b)

1999

c)

1994

d)

1984

36.

If water contains animal waste, butchery and human faecal matter, which UK fluid category does this water come under?

a)

2

b)

4

c)

5

d)

3

37.

What is the difference between fluid category 4 and Fluid category 5?

a)

Fluid category 4 has less effluent than fluid category 5

b)

Exposure to fluid category 4 water may take weeks or months to cause harm, whereas exposure to fluid category 5 water may take hours or days to cause harm?

c)

Fluid category 5 has more germs in it

d)

Fluid category 4 is fresh water, whereas fluid category 5 has its colour or taste changed due to contact with a substance or due to temperature.

38.

Before water can be considered clean and fit to drink, which processes must it go through?

a)

filtration, aeration, settlement, purification

b)

sedimentation, filtration, sterilisation, aeration

c)

sedimentation, filtration, purification, aeration

d)

sedimentation, filtration, percolation, aeration

39.

What is the 'schmutzedecke' ?

a)

A layer of sand and algae

b)

A film of floating floc

c)

A biological layer of sludge

d)

A layer of faecal matter

40.

The Water Regulations main aim is to prevent the following five items from happening? These are?

a)

Contamination of water and the wastage of water

b)

Misuse of water and the undue consumption of water

c)

The erroneous metering of water

d)

All of the above

41.

If a part of an installation becomes redundant, the pipe work should be

a)

Insulated

b)

Earthed

c)

Disconnected

d)

Clipped

42.

One of the major problems when leaving a dead leg in a cold water pipe is

a)

Electrolytic corrosion

b)

Pitting of pipework

c)

Reduction in water flow

d)

Possible bacterial growth

43.

What would be done after sound testing of a new completed cold water system

a)

Visual inspection with the customer

b)

Flush the pipework out then hand over to the customer

c)

Prepare the benchmark certificate

d)

Hand over to the customer

44.

What is the most cost effective way to repair a stop valve that has the head gear jammed open

a)

Replace the head gear only

b)

Replace the whole valve

c)

Leave in position, and install a new stop valve upstream

d)

Repack the glands around the spindle

45.

When decommissioning a system, the correct procedure is to

a)

Turn off the water quickly to save any wasted water

b)

Drain the system down then inform the customer

c)

Inform the customer and other trades first then drain the system

d)

Use a pump to drain down quickly

46.

What is this item?

a)

Fullway gate valve

b)

Drain off valve

c)

Stop Valve

d)

Spherical Ball valve

47.

What type of valve is shown in the diagram?

a)

Spherical Ball Valve

b)

Fullway Gate valve

c)

Stop valve

d)

Spherical Ball Valve

48.

Which of the following materials is not allowed to be installed on new cold water systems?

a)

Copper

b)

Stainless steel

c)

MDPE

d)

Lead

49.

Which valve is designed to shut off the supply of water in a cistern at a predetermined level

a)

Stop Valve

b)

Fullway Gate valve

c)

Float Operated Valve

d)

Isolation Valve

50.

If a hand basin has submerged taps, Which backflow device must be installed

a)

Overflow

b)

Single Check valve

c)

Double Check valve

d)

Auk 3 air gap

51.

Fluid category 1 represents

a)

A serious health risk

b)

A significant health risk

c)

A Slight health risk

d)

No health risk

52.

Which backflow prevention device must be installed on a supply to a hose union bib tap?

a)

Auk 2 air gap

b)

Single check valve

c)

Fullway gate valve

d)

Double check valve

53.

The plastic medium density supply pipe, which is blue, is manufactured from which material?

a)

Polyethelene

b)

Polystyrene

c)

Polypropylene

d)

Polybutylene

54.

mixer tap which allows hot/cold water to mix in body of tap with unbalanced pressure must have

a)

Double check valve on both hot and cold supplies

b)

Single check valve of both hot and cold supplies

c)

AUK 2 air gap

d)

AUK 3 air gap

55.

The fluid category that offers a slight health risk is:

a)

1

b)

3

c)

2

d)

4

56.

The correct back flow protection device that would be installed prior to a shower mixer valve

a)

Single check valve

b)

Double Check Valve

c)

RPZ Valve

d)

Type AG air gap

57.

What would this item be used to test?

a)

Pressure

b)

Category of water

c)

Flow rate

d)

PH Value

58.

If a customers tap is dripping, what tool can be used to correct the situation?

a)

Club hammer

b)

Stillsons

c)

Spanner

d)

Re-seating tool

59.

Where should the cold water distributing pipe be connected to the cistern?

a)

In the air gap 40mm up

b)

Below the cold water storage cistern 50mm down

c)

In the attic 50 mm up

d)

In the side 25mm up

60.

The holes to a cold water storage cistern are made using what type of saw?

a)

Hole saw

b)

Hack saw

c)

Reciprocating saw

d)

Circular saw

61.

What type of cold water system is used on high incoming water pressure

a)

Boosted

b)

Direct

c)

Indirect

d)

Inter Boosted

62.

When installing a new indirect cold water system, which of the following should happen?

a)

One tap (Kitchen sink) drawn from supply pipe

b)

One tap(kitchen sink)should have distribution pipe from cistern

c)

Mixer taps will require double check valves

d)

Mixer taps should never be installed due to pressure differ