pp2 Central Heating System 1.3

Total questions: 10

Worksheet time: 5mins

Name
Class
Date
1.

What is the term used for older central heating systems that rely on the principle of convection for heat circulation?

a)

Forced circulation

b)

Two-pipe semi-gravity system

c)

Gravity circulation

d)

Pumped systems

2.

What is the primary function of the open vent pipe in a one-pipe semi-gravity system?

a)

To discharge steam/water in a fault condition

b)

To allow filling of the system from the F&E cistern

c)

To control room temperature

d)

allow for expansion and contraction to provide a safety outlet in case of overheating

3.

What is the drawback of a one-pipe semi-gravity system in terms of the temperature of each radiator?

a)

The temperature of the radiators is unpredictable

b)

Each radiator is progressively hotter than the previous

c)

Each radiator is progressively cooler than the previous

d)

All radiators have the same temperature

4.

What is the purpose of the feed and expansion (F&E) cistern in a one-pipe semi-gravity system?

a)

To accommodate system expansion

b)

To provide static head for the heating system

c)

All of the above

d)

To keep the system topped up after slight water loss

5.

In a two-pipe semi-gravity system, what controls the heating by switching off the pump?

a)

Programmer

b)

Room thermostat

c)

22mm vent pipe

d)

Boiler

6.

What is the advantage of a two-pipe semi-gravity system in terms of heat emitters?

a)

Heat emitters are not efficient

b)

All heat emitters reach the same temperature

c)

All heat emitters have different temperatures

d)

Heat emitters are not affected by the system

7.

What is the disadvantage of a two-pipe semi-gravity system in terms of heat control?

a)

Uncontrolled heat

b)

Controlled heat

c)

Heat is not distributed evenly

d)

Heat emitters do not reach the same temperature

8.

What is the primary difference between a one-pipe semi-gravity system and a two-pipe semi-gravity system?

a)

The number of pipes used

b)

The type of heat emitters used

c)

The control mechanism used

d)

The type of boiler used

9.

What is the purpose of the neutral point in a one-pipe semi-gravity system?

a)

To ensure equal suction by the circulating pump

b)

To keep the system topped up after slight water loss

c)

To provide static head for the heating system

d)

To allow filling of the system from the F&E cistern

10.

What is the recommended minimum height for the open vent pipe in a one-pipe semi-gravity system?

a)

350mm

b)

450mm

c)

250mm

d)

150mm