WorksheetsExit Routes, EAPs, FPPs and Fire Prevention Quiz
Total questions: 15
Worksheet time: 8mins
Which of the following statements is TRUE regarding Emergency Action Plans (EAPs)?
EAPs need to be written down only if requested by employees.
EAPs facilitate and organize actions taken during an emergency.
EAPs have no effect on the number or severity of injuries during an emergency.
EAPs increase confusion due to the number of documents required.
Fire Prevention Plan (FPP) requirements include all of the following, except ___.
FPPs can be communicated orally if there are more than 10 employees
The employer must review with each employee the parts of the FPP necessary for self-protection
It must be written document that is kept in the workplace
It must be made available to employees for review
Which of the following elements are required in order for a fire to occur?
Sufficient oxygen, fuel, ignition source, and chemical reaction
Sufficient fuel, carbon dioxide, heat, and chemical reaction
Combustible materials, spark, heat, and mechanical reaction
Smoke, heat, flames, and light reaction
Only those employees who have received training on the use of a fire extinguisher can be authorized to use a fire extinguisher during a workplace fire.
True
False
Which of the following statements represents an element of a good emergency evacuation floor plan?
Designates one exit pathway so as not to confuse evacuees
Indicates locations of elevators used to reach emergency exit
Directs exits away from rooms with hazardous materials
Indicates restrooms and windows as potential exits
Trash fires involving paper and wood products are __ fires.
Class C
Class B
Class D
Class A
Which fire extinguisher is appropriate for use on a fire involving gasoline in a confined space when no respiratory protection is available?
Carbon dioxide extinguisher
Dry chemical extinguisher
Water (APW) extinguisher
Class K dry-type extinguisher
The P.A.S.S. technique for using a fire extinguisher means ___.
Position, aim, sweep, slowly
Point, away, side-to-side
Pin, approach, start, stop
Pull, aim, squeeze, sweep
At minimum, how often must maintenance checks be performed on portable fire extinguishers?
Once a month
Once every five years
Once a year
Once every two years
Which of the following elements is NOT required in order for a fire to occur?
Chemical reaction
Fuel
Ignition source
Sufficient oxygen
What is the first step in using a fire extinguisher under the P.A.S.S. technique?
Approach the fire
Squeeze the handle
Pull the pin
Sweep side to side
Which of the following is NOT a type of fire extinguisher?
Water (APW) extinguisher
Carbon dioxide extinguisher
Dry chemical extinguisher
Class Z extinguisher
What is the minimum frequency for conducting fire drills in a workplace?
Once a month
Once every six months
Once a year
Once every two years
What is the second step in using a fire extinguisher under the P.A.S.S. technique?
Approach the fire
Squeeze the handle
Pull the pin
Aim at the base of the fire
Which type of fire extinguisher is suitable for electrical fires?
Water (APW) extinguisher
Carbon dioxide extinguisher
Dry chemical extinguisher
Class K dry-type extinguisher
