wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

SPLE Rule 7 NBCP

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

Minimum thickness of CMU Wall with 2 hours Fire resistive rating

a)

300mm

b)

250mm

c)

200mm

d)

150mm

2.

Minimum thickness of CMU Wall with 1 hours Fire resistive rating

a)

300mm

b)

250mm

c)

200mm

d)

150mm

3.

Identify the occupancy of the proposed Project:
Mental Hospital

a)

Group D

b)

Group A

c)

Group B

d)

Group C

4.

Identify the occupancy of the proposed Project:
Reformatories

a)

Group D

b)

Group A

c)

Group B

d)

Group C

5.

Identify the occupancy of the proposed Project:
Day-care

a)

Group D

b)

Group A

c)

Group B

d)

Group C

6.

Identify the occupancy of the proposed Project:
Assembly building less than 1000 occupant

a)

Group J

b)

Group K

c)

Group H

d)

Group I

7.

Identify the occupancy of the proposed Project:
Assembly building more than 1000 occupant

a)

Group J

b)

Group K

c)

Group H

d)

Group I

8.

Identify the occupancy of the proposed Project:
Zoos

a)

Group J

b)

Group K

c)

Group H

d)

Group I

9.

There are 10 Groups of Occupancies sub-divided into ___ Divisions.

a)

32

b)

25

c)

15

d)

45

10.

Identify Zoning Classification
Single detached dwellings.

a)

R-1

b)

C-1

c)

R-2

d)

R-3

11.

Identify Zoning Classification
Duplex Building/Structure

a)

R-1 Max

b)

R-2 Max

c)

R-2 Basic

d)

R-3

12.

Identify Zoning Classification
Low rise multiple level building with 3 to 5 storey

a)

R-1 Max

b)

R-2 Max

c)

R-2 Basic

d)

R-3

13.

Identify Zoning Classification
Rowhouse building

a)

R-1 Max

b)

R-2 Max

c)

R-3 Max

d)

R-3 Basic

14.

Identify Zoning Classification
Medium Rise multi level building with 6-12 storey

a)

R-1 Max

b)

R-2 Max

c)

R-3 Max

d)

R-3 Basic

15.

Identify Zoning Classification
Townhouse

a)

R-4

b)

R-2 Max

c)

R-3 Max

d)

R-3 Basic

16.

Identify Zoning Classification
Condominium

a)

R-4

b)

R-6

c)

R-5

d)

R-3 Basic

17.

R-1 is Firewall is not allowed. However, an abutment up to ____ high is OK for carport provided that above 1.5m, the abutment shall be constructed of perforated blocks

a)

3.5m

b)

3.2m

c)

2.5m

d)

1.5m

18.

R-1 is Firewall is not allowed. However, an abutment up to 3.2m high is OK for carport provided that above 1.5m, the abutment shall be constructed of perforated or decorative block

a)

3.5m

b)

3.2m

c)

2.5m

d)

1.5m

19.

Allowable firewall for R-2

a)

One side

b)

Two Side

c)

Three Side

d)

Exempted

20.

Allowable firewall for R-3

a)

One side

b)

Two Side

c)

Three Side

d)

Exempted