Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Motor Starters Quiz Level 3's

Total questions: 18

Worksheet time: 9mins

Name
Class
Date
1.

What does DOL stand for in the context of motor starters?

a)

Direct-on-line

b)

Duration-of-line

c)

Direct-overload-line

d)

Drive-on-line

2.

Which of the following is NOT a characteristic of a DOL starter?

a)

'on and off' switch

b)

Speed control

c)

No speed control

d)

Can be used with Single- or Three-phase motors

3.

What is the function of the overload contact in a motor control circuit?

a)

To start the motor

b)

To stop the motor

c)

To protect the motor from overloads

d)

To control the motor speed

4.

What type of motor control is depicted in the image?

a)

Direct on-line

b)

Star-delta

c)

Soft start

d)

Variable frequency drive

5.

At what voltage does the motor start in a star-delta control system?

a)

400V

b)

230V

c)

110V

6.

After a set period in a star-delta control system, to what voltage does the voltage increase?

a)

230V

b)

110V

c)

400V

d)

It remains the same

7.

Is the star-delta motor control system suitable for single-phase or three-phase motors according to the image?

a)

Single-phase only

b)

Three-phase only

c)

Both single-phase and three-phase

d)

Neither single-phase nor three-phase

8.

What is a characteristic of a Soft Start in motor control?

a)

It starts at full voltage

b)

It decreases the voltage as it reaches full speed

c)

It starts on a reduced voltage

d)

It is always inexpensive

9.

What happens to the voltage as a motor with Soft Start reaches full speed?

a)

The voltage remains constant

b)

The voltage is reduced further

c)

The voltage is increased to full load

d)

The voltage fluctuates unpredictably

10.

What type of phases can Soft Start be applied to?

a)

Single-phase only

b)

Three-phase only

c)

Single- or Three-phase

d)

Multi-phase

11.

What does a Variable Frequency unit do?

a)

Adjusts the speed of the motor only

b)

Adjusts the torque of the motor only

c)

Adjusts frequency and voltage

d)

Adjusts the color of the motor

12.

How does a motor with Variable Frequency start?

a)

Rapidly, reaching full load instantly

b)

Slowly, until full load and torque are reached

c)

At a constant speed, regardless of load

d)

With full torque, regardless of speed

13.

Can Variable Frequency be considered an inexpensive solution for motor control?

a)

Yes, it is always inexpensive

b)

No, it can be expensive

c)

Yes, it is the cheapest solution available

d)

No, it is moderately priced

14.

What type of phases can Variable Frequency be applied to?

a)

Single-phase only

b)

Three-phase only

c)

Single- and Three-phase

d)

Multi-phase

15.

What is the purpose of starting with increased resistance on the rotor in wound rotor motors?

a)

To increase motor speed

b)

To limit current flow

c)

To reduce motor torque

d)

To make the motor cheaper

16.

What happens when the resistance in the rotor of a wound rotor motor is reduced?

a)

The motor speed and torque decrease

b)

The motor becomes less expensive

c)

The motor speed and torque increase

d)

The motor requires single-phase power

17.

What is a characteristic of rotor resistance in wound rotor motors?

a)

It makes the rotor lighter and cheaper

b)

It is used in single-phase motors

c)

It requires a smaller rotor

d)

It is expensive and bulky

18.

What type of power supply is required for motors that use rotor resistance control?

a)

Single phase

b)

Two phase

c)

Three phase

d)

Direct current (DC)