wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Central heating trail 4

Total questions: 1

Worksheet time: 23mins

Name
Class
Date
1-41.
1.

What percentage of heat is convected via the fins welded to the back of modern radiators found in new-build properties?

a)

50%

b)

75%

c)

85%

d)

95%

2.

What is the recommended minimum distance from floor height for installing panel radiators?

a)

100mm

b)

150mm

c)

200mm

d)

250mm

3.

Radiators that do not have fins rely on what type of heat?

a)

Convected heat

b)

Radiated heat

c)

Conducted heat

d)

Reflected heat

4.

Where should panel radiators be installed to ensure proper convection flow?

a)

Close to windows

b)

Near doorways

c)

Where obstructions will not interfere

d)

Directly under light fixtures

5.

What does TBOE stand for in radiator piping configurations?

a)

Top - Bottom - Opposite ends

b)

Top - Bottom - Same end

c)

Bottom - Top - Opposite ends

d)

Bottom - Bottom - Opposite ends

6.

Which radiator piping configuration is described as the most efficient but can look unsightly?

a)

TBOE

b)

BBOE

c)

TBSE

d)

None of the above

7.

What is the usual and most common method to pipe radiators?

a)

TBOE

b)

BBOE

c)

TBSE

d)

None of the above

8.

Which of the following is NOT a type of radiator top mentioned in the document?

a)

Seam top

b)

Compact

c)

Rolled top

d)

Flat top

9.

Where are kickspace heaters typically installed?

a)

Under the kitchen unit or vanity unit

b)

On the wall in the living room

c)

In the ceiling of the bathroom

d)

Outside the house

10.

What is the purpose of a kickspace heater?

a)

To cool the room by blowing in cold air

b)

To heat the room by blowing in warm air

c)

To filter the air in the room

d)

To dehumidify the room

11.

What is the main advantage of a fan convector compared to other types of heaters?

a)

It uses natural convection only.

b)

It can heat up large areas quickly.

c)

It is installed around a room.

d)

It offers background heating.

12.

What is the main disadvantage of a skirting convector?

a)

It cannot heat up large areas quickly.

b)

It is not made from steel or aluminium.

c)

Dust can block the fins and stall the convection current.

d)

It has a low heat output.

13.

What material are modern column radiators made from, besides cast iron?

a)

Plastic and wood

b)

Steel and aluminium

c)

Copper and brass

d)

Glass and ceramic

14.

Where can column radiators still be found?

a)

Only in industrial settings

b)

Exclusively in outdoor environments

c)

In public buildings and retro-fit properties

d)

They are no longer in use

15.

For what purpose were Low surface temperature radiators originally designed?

a)

For high-temperature industrial applications

b)

For the National Health Service (NHS) where a lower surface temperature was required

c)

For outdoor heating solutions

d)

For automotive heating systems

16.

What is the maximum surface temperature that Low surface temperature radiators could have according to their original design for the NHS?

a)

30°C

b)

43°C

c)

50°C

d)

60°C

17.

Which of the following is NOT a place where Low surface temperature radiators were accepted for use?

a)

Nurseries

b)

Primary schools

c)

Commercial office buildings

d)

Homes for the elderly

18.

Towel rails can be used with which types of heating systems?

a)

Only with wet central heating systems

b)

Only with electrical elements

c)

Either with wet central heating systems or independently with an electrical element

d)

Only with solar heating systems

19.

Which of the following is NOT a style mentioned for towel rails?

a)

Inverted radiator

b)

Conventional tubular style

c)

Designer style

d)

Compact disc style

20.

How does underfloor heating differ from conventional heat emitters?

a)

It cools the floor instead of heating it

b)

It uses air as the primary heat transfer medium

c)

It uses pipework laid under the screed-in boards to heat the floor

d)

It is only used for outdoor heating

21.

What is the minimum temperature required at the manifold for underfloor heating systems?

a)

40°C

b)

55°C

c)

65°C

d)

85°C

22.

Which of the following is an advantage of underfloor heating?

a)

High installation costs

b)

Takes longer to heat up a room

c)

Lower potential fuel costs for the customer

d)

Tends to be little or no condensation

23.

What is a disadvantage of underfloor heating?

a)

Even heat over the floor area

b)

No heat emitters on the wall

c)

High component costs

d)

Suited to solar systems

24.

For correct heat transfer in an underfloor heating system, how is the flow rate typically set?

a)

Fast

b)

Moderate

c)

Slow

d)

Variable

25.

Underfloor heating is particularly suited to which type of energy source?

a)

Nuclear

b)

Solar

c)

Wind

d)

Fossil fuels

26.

What does BS EN 442 specify for?

a)

The temperature difference in radiators

b)

The specification for radiators and convectors

c)

The environmental issues related to heating systems

d)

The best practices for installing heating systems

27.

What is Delta T in the context of sizing radiators?

a)

The average temperature of the radiator

b)

The flow temperature from the boiler

c)

The difference in temperature between the mean radiator temperature and the ambient temperature of the room

d)

The temperature of the room

28.

When installing a heating system, which of the following is NOT a consideration for the plumber?

a)

Cost effectiveness

b)

Control of the system

c)

Environmental issues

29.

What is the average radiator temperature if the flow in is 80 °C and the flow out is 60 °C?

a)

70 °C

b)

60 °C

c)

80 °C

d)

20 °C

30.

What does Delta T equal if the average radiator temperature is 70 °C and the room temperature is 20 °C?

a)

50 °C

b)

70 °C

c)

20 °C

d)

90 °C

31.

Where are radiator valves normally installed in the UK?

a)

In the top female tappings of the radiator

b)

In the bottom female tappings of the radiator (BBOE)

c)

On the exterior of the radiator

d)

In the middle section of the radiator

32.

What is the purpose of wheelhead valves on a radiator?

a)

To balance the system

b)

To control the temperature

c)

To allow the customer to turn the radiator on and off

d)

To drain and remove the radiator

33.

What is the difference between a lock shield valve and a wheelhead valve?

a)

A lock shield valve is used for balancing the system, while a wheelhead valve is for temperature control

b)

A lock shield valve allows the customer to turn the radiator on and off, while a wheelhead valve is for balancing

c)

A lock shield valve is for draining the radiator, while a wheelhead valve is for removing it

d)

A lock shield valve has a wheelhead removed and prevents customer interference, while a wheelhead valve allows customer control

34.

Why are thermostatic radiator valves (TRVs) installed?

a)

To allow the plumber/engineer to balance the system

b)

To enable the radiator to be drained and removed

c)

To allow temperature control of a single radiator

d)

To prevent the customer from interfering with the radiator

35.

Under which regulations are thermostatic radiator valves (TRVs) required as best practice?

a)

Building Regulations part K

b)

Building Regulations part L

c)

Building Regulations part M

d)

Building Regulations part N

36.

What does the head of a TRV contain that reacts to ambient air temperature?

a)

A volatile solid

b)

A volatile liquid

c)

A non-volatile liquid

d)

A gas sensor

37.

According to Building Regulations, which radiator in the circuit should be left without a TRV fitted?

a)

The bathroom radiator

b)

The bedroom radiator

c)

The kitchen radiator

d)

The hallway radiator

38.

What should be fitted to a radiator valve when a TRV is removed for decorating?

a)

A locking cap

b)

A decorator's cap

c)

A sealing cap

d)

A pressure cap

39.

What tool is required by the plumber to secure the valve stems, regardless of the type of valve installed?

a)

A wrench

b)

A screwdriver

c)

A valve key

d)

Pliers

40.

How many valves and blanking plates are located in the four ½" BSP radiator inlets?

a)

Two valves and two blanking plates

b)

Three valves and one blanking plate

c)

Two valves and one blanking plate

d)

One valve and two blanking plates

41.

Where is the bleed valve located in the four ½" BSP radiator inlets?

a)

In one of the bottom inlets

b)

In one of the side inlets

c)

In one of the top inlets

d)

In the center inlet