wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Installation LEVEL 3 Quiz

Total questions: 18

Worksheet time: 9mins

Name
Class
Date
1.

Which of the following documents should be available to a site electrician during the construction phase of an electrical installation?

a)

Risk assessment Method Statement

b)

Manufacturer’s instructions / Data sheets

c)

Building regulations

d)

All of the above

2.

Which of the following is a type of inductive transformer?

a)

Isolation / separation

b)

Laminated core

c)

Single phase

d)

Direct current transformer

3.

Why is pumped storage electricity generation used in preference to traditional fuel sources?

a)

It is cheaper to operate

b)

It provides supply flexibility when demand fluctuates

c)

It requires less maintenance

d)

It uses solar energy

4.

A single-phase electric motor has a rating of 2.55 kW and the current lags the voltage by 32°. Calculate the apparent power.

a)

2.55 kVA

b)

3 kVA

c)

1.59 kVA

d)

0.85 kVA

5.

Why must all live conductors of the same A.C. circuit enter a steel-cased consumer unit through one single hole?

a)

To reduce the length of the conductors

b)

To ensure the magnetic fields induced by each conductor are offset by the opposing fields

c)

To make the installation process easier

d)

To increase the voltage of the circuit

6.

Which of the following gases or metallic vapours is commonly used in discharge lamps?

a)

Neon

b)

Oxygen

c)

Nitrogen

d)

Carbon Dioxide

7.

Why is star-delta motor control equipment used in preference to direct-on-line?

a)

It reduces the line current during start-up and increases the torque while running

b)

It is cheaper to install

c)

It requires less maintenance

d)

It is more energy-efficient

8.

What is one of the drawbacks of BS 3036 fuses?

a)

They have a high fusing factor

b)

They are very expensive

c)

They can overheat and potentially cause a fire

d)

They are difficult to replace

9.

Which of the following is a factor to be taken into account when calculating the maximum demand of an installation according to BS 7671?

a)

The color of the cables

b)

The location of points of power demand

c)

The brand of the equipment

d)

The type of insulation used

10.

Which of the following factors should be considered when designing a lighting system?

a)

Anticipated future demand

b)

Color of the walls

c)

Number of windows

d)

Type of flooring

11.

What is the purpose of adjusting sensors to test settings in a hotel corridor?

a)

To change the color of the lights

b)

To activate lights when people move in appropriate locations

c)

To increase the brightness of the lights

d)

To turn off the lights during the day

12.

Which of the following is NOT a practical measure to ensure the safety of other people during inspection and testing?

a)

Informing people of dangers

b)

Posting signs for awareness

c)

Ensuring lifts are occupied

d)

Providing adequate lighting for safe access/egress

13.

Why must a newly installed gas central heating boiler be disconnected from a circuit before an insulation resistance test?

a)

To prevent overheating

b)

To avoid false readings and damage to sensitive electronic components

c)

To save energy

d)

To ensure the boiler is working properly

14.

Which of the following hazardous materials may require specialist disposal when undertaking fault rectification work?

a)

Wood

b)

Plastic

c)

Mercury

d)

Paper

15.

Identify three pieces of verbal information an electrician should seek from a user when undertaking diagnosis of an intermittent electrical fault.

a)

How long has the fault been occurring

b)

What is the color of the wires

c)

How often does the fault occur

d)

Is anything else happening at the time the fault occurs

16.

State the upper voltage limits for Extra-Low Voltage.

a)

50 V ac

b)

100 V ac

c)

120 V dc

d)

200 V dc

17.

Explain the effect of running a cable through 200 mm of thermal insulation.

a)

The thermal insulation will increase the ability of the cable to dissipate heat

b)

The thermal insulation will reduce the ability of the cable to dissipate heat

c)

The current carrying capacity of the cable will increase

d)

The correction factor to be applied is 0.75

18.

Explain why Low Voltage circuits with surge protective devices may have the insulation resistance test voltage reduced.

a)

Low voltage circuits are normally tested at 500 V, which is sufficient to operate the surge protection

b)

Low voltage circuits are normally tested at 1000 V, which is sufficient to operate the surge protection

c)

Reducing the test voltage to 250 V will stop the operation of the surge protective device

d)

Reducing the test voltage to 100 V will stop the operation of the surge protective device