6035 Drainage Outcome 1 part 1

Total questions: 43

Worksheet time: 22mins

Name
Class
Date
1.

Which part of the Building Regulations deals with drainage and waste disposal?

a)

Part G

b)

Part H

c)

Part N

d)

Part A

2.

What does Building Regulations part G cover?

a)

Drainage and waste disposal

b)

Electrical safety

c)

Sanitation, hot water safety, and water efficiency

d)

Fire safety

3.

In which regions are Building Regulations statutory requirements for drainage systems?

a)

Scotland and Wales

b)

England and Wales

c)

Northern Ireland and Scotland

d)

England and Scotland

4.

What does BS 8000: pt 13 refer to?

a)

Good safety practices

b)

Good environmental practices

c)

Good workmanship

d)

Good manufacturing practices

5.

Why is it important to follow manufacturers' instructions carefully?

a)

They are always the same

b)

They vary and ensure proper use

c)

They are optional

d)

They are only for reference

6.

What is the primary function of drainage pipework systems in a dwelling?

a)

To supply clean water to appliances

b)

To take solid and liquid wastes out of the dwelling

c)

To regulate indoor temperature

d)

To provide ventilation

7.

Why must drainage pipework systems be done safely and hygienically?

a)

To prevent water wastage

b)

To avoid any health problems

c)

To reduce noise pollution

d)

To save energy

8.

Through what components is the waste product discharged in a drainage pipework system?

a)

Through a filter, down a discharge pipe, to a water tank

b)

Through a trap, down a discharge branch, to a soil stack, and to the underground sewer

c)

Through a valve, down a discharge pipe, to a septic tank

d)

Through a pump, down a discharge branch, to a soil stack, and to the underground sewer

9.

What is the function of the vent pipe in a standard domestic soil stack?

a)

To allow air to enter the system to operate at atmospheric pressure

b)

To remove waste water from the dwelling

c)

To heat the water in the system

d)

To filter the air entering the system

10.

What could happen if the pressure in the vent pipe varies?

a)

It could lead to trap seal loss, allowing foul air to enter the dwelling

b)

It could cause the system to overheat

c)

It could result in water contamination

d)

It could increase water pressure in the system

11.

What is the function of the soil pipe in a soil stack system?

a)

To provide ventilation

b)

To take all the effluent away from the building

c)

To supply fresh water

d)

To support the structure of the building

12.

Which standards must all soil stack systems comply with?

a)

Part A and BS EN 12056

b)

Part B and BS EN 12056

c)

Part H and BS EN 12056

d)

Part C and BS EN 12056

13.

Which standards must appliances, pipes, and fittings comply with?

a)

American standards

b)

European standards

c)

Asian standards

d)

Australian standards

14.

What is the purpose of providing drainage for all water supply points inside the building?

a)

To prevent water wastage

b)

To prevent flooding

c)

To increase water pressure

d)

To reduce water temperature

15.

What must be installed with appliances connected to the drainage system to prevent foul air from entering the building?

a)

A filter

b)

A pump

c)

A trap

d)

A valve

16.

What is the minimum depth of water seal in a trap according to the compliance requirements?

a)

25mm

b)

50mm

c)

75mm

d)

100mm

17.

What must the waste pipe diameter and gradient maintain after an appliance has been used?

a)

A trap seal depth of at least 10mm

b)

A trap seal depth of at least 25mm

c)

A trap seal depth of at least 50mm

d)

A trap seal depth of at least 75mm

18.

What should not be reduced in the direction of flow according to the compliance requirements?

a)

The depth of water seal

b)

The waste pipe diameter

c)

The nominal diameter of the discharge pipe

d)

The gradient of the waste pipe

19.

What must be adequately sized when used to vent drainage systems?

a)

Water seals

b)

Waste pipes

c)

Discharge pipes

d)

Air admittance valves

20.

Why does the primary ventilated stack not require extra ventilation?

a)

It has a built-in fan

b)

It uses a special filter

c)

The discharge branches are closely grouped around the stack

d)

It is located outdoors

21.

What is the function of the soil stack in a primary ventilated stack system?

a)

To filter water

b)

To allow pressure fluctuations without affecting the trap seal loss

c)

To provide extra ventilation

d)

To store waste

22.

What type of system is depicted in the image?

a)

Secondary ventilated stack

b)

Primary ventilated stack

c)

Combined stack system

d)

Separate stack system

23.

How far is the invert of the drain from the base ?

a)

300mm

b)

450mm

c)

600mm

d)

750mm

24.

What does the term "self-cleaning velocity" mean in the context of a primary ventilated stack system?

a)

The liquid flows slowly to prevent blockage.

b)

The liquid carries the solids as it flows, reducing the risk of blockage.

c)

The liquid is filtered before entering the stack.

d)

The liquid is treated with chemicals to prevent blockage.

25.

What is the maximum length (in meters) for the waste pipe of a WC?

a)

1.7

b)

3.0

c)

6.0

d)

3.5

26.

What is the waste size (in mm) for a basin or bidet?

a)

40

b)

32

c)

75

d)

100

27.

What is the gradient range (in mm/m) for a washing machine/dishwasher waste pipe?

a)

18-22

b)

18-50

c)

18-90

d)

18-75

28.

What is the trap seal depth (in mm) for a bath (40mm)?

a)

50

b)

75

c)

32

d)

100

29.

Which appliance has a waste size of 40 mm and a maximum length of 3.0 meters?

a)

WC

b)

Basin or bidet

c)

Washing machine/dishwasher

d)

Sink

30.

Where are junior WCs often installed?

a)

High schools

b)

Colleges

c)

Nursery schools and infant schools

d)

Universities

31.

If an installation exceeds the maximum length stated, what should the next pipe size up be for a 32mm pipe?

a)

35mm

b)

40mm

c)

45mm

d)

50mm

32.

If an installation exceeds the maximum length stated, what should the next pipe size up be for a 40mm pipe?

a)

45mm

b)

55mm

c)

50mm

d)

60mm

33.

What is the minimum pipe size that should be used if multiple appliances are connected to a single discharge pipe?

a)

32mm

b)

40mm

c)

45mm

d)

50mm

34.

What is the purpose of installing a long radius bend at the base of a soil stack?

a)

To increase the effluent's temperature

b)

To maintain the effluent's velocity when changing from vertical to horizontal movement

c)

To reduce the effluent's velocity

d)

To increase the effluent's pressure

35.

What problem did older systems without a long radius bend face?

a)

Increased effluent temperature

b)

Reduced effluent velocity

c)

Compression or back pressure for the discharge

d)

Increased effluent pressure

36.

What alternative to a long radius bend is mentioned in the text?

a)

A single 90 degree connector

b)

Two 45 degree connectors

c)

A straight pipe

d)

A flexible hose

37.

Where is it good practice to position a rodding access in a primary ventilated stack?

a)

At the top of the stack

b)

Just above ground level, at the base of the stack

c)

In the middle of the stack

d)

At the end of the stack

38.

What is the lowest connection to the soil stack on low-rise buildings (two storeys) from the drain invert level?

a)

450mm

b)

500mm

c)

600mm

d)

750mm

39.

For buildings up to five storeys, what is the minimum distance from the drain invert level to the lowest connection to the soil stack?

a)

450mm

b)

500mm

c)

600mm

d)

750mm

40.

What type of entrance or angle should branch connections to the soil stack be made with to aid the flow of effluent?

a)

Swept entrance or at an angle

b)

Straight entrance

c)

Perpendicular entrance

d)

Horizontal entrance

41.

What must be avoided to prevent trap seal loss and effluent crossflow in a primary ventilated stack system?

a)

Installing connections at the same height

b)

Installing connections at different heights

c)

Installing connections at a vertical distance of 300mm

d)

Installing connections at a vertical distance of 100mm

42.

What is the vertical distance downwards that no other connection may be installed opposite to an existing branch connection to avoid crossflow?

a)

100mm

b)

150mm

c)

200mm

d)

250mm

43.

What is the range of the existing branch connection to a stack where no other connection may be installed opposite to avoid crossflow?

a)

50-100mm

b)

82-160mm

c)

100-200mm

d)

120-180mm