Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Water Regulations Quiz

Total questions: 57

Worksheet time: 29mins

Name
Class
Date
1.

Which of the following is a guide related to water regulations?

a)

The Water Regulations Guide (WRAS)

b)

Building Regulations Part G

c)

Directory of fittings (WRAS approved)

d)

The Water Regulations (1999)

2.

What does WRAS stand for?

a)

Water Regulation Advisory Scheme

b)

Water Regulation Approval System

c)

Water Regulation and Safety

d)

Water Regulation and Standards

3.

Which document is related to building regulations?

a)

Building Regulations Part G

b)

The Water Regulations Guide (WRAS)

c)

Directory of fittings (WRAS approved)

d)

The Water Regulations (1999)

4.

Which of the following is a directory of fittings approved by WRAS?

a)

Directory of fittings (WRAS approved)

b)

The Water Regulations Guide (WRAS)

c)

Building Regulations Part G

d)

The Water Regulations (1999)

5.

What does BS6700 cover?

a)

Workmanship on building sites

b)

Design, installation, testing, and maintenance

c)

Code of practice for hot and cold water services

d)

Electrical installations

6.

What is the focus of BS8000 pt15?

a)

Design, installation, testing, and maintenance

b)

Electrical installations

c)

Workmanship on building sites

d)

Fire safety regulations

7.

What does BS8000 pt15 specifically address?

a)

Electrical installations

b)

Fire safety regulations

c)

Code of practice for hot and cold water services

d)

Design, installation, testing, and maintenance

8.

What do manufacturers' instructions typically outline?

a)

Installation requirements, maintenance and servicing requirements, fault diagnosis, and spare parts

b)

Marketing strategies and sales targets

c)

Employee training programs and schedules

d)

Customer feedback and reviews

9.

What additional details do manufacturers' instructions list?

a)

Flow rates and maximum temperatures for appliances

b)

Warranty periods and return policies

c)

Customer service contact information

d)

Product color options and design features

10.

What are the two main categories of hot water supply systems?

a)

Centralised system and Localised or single-point system

b)

Instantaneous and Storage

c)

Thermal store and Gas-fired

d)

Direct and Indirect

11.

Which of the following is a type of instantaneous hot water system?

a)

Gas storage water heater

b)

Combi boiler or instantaneous water heater

c)

Open-vented hot water heater

d)

Unvented hot water heater

12.

Which type of system is classified under both centralised and localised systems?

a)

Gas-fired

b)

Electric

c)

Open-vented hot water heater

d)

Unvented hot water heater

13.

What type of system is a 'Combination vented "fortic" system' classified under?

a)

Instantaneous

b)

Storage

c)

Localised

d)

Direct

14.

Which of the following is NOT a type of storage system?

a)

Gas storage water heater

b)

Unvented / mains-fed system

c)

Thermal store

d)

Immersion heater

15.

What is the definition of a centralised hot water system?

a)

Water is heated to a specific temperature for domestic use.

b)

Water is heated and/or stored centrally in the building and is distributed from that point to all the hot water outlets.

c)

Water is heated and/or stored locally to one specific draw-off point area.

d)

Water is heated on demand when hot water outlets are opened.

16.

Which type of hot water system involves heating water on demand when hot water outlets are opened?

a)

Centralised

b)

Localised

c)

Stored

d)

Instantaneous

17.

In which type of hot water system is a cylinder of water heated to temperature before being distributed to the hot water outlets?

a)

Hot water

b)

Centralised

c)

Stored

d)

Instantaneous

18.

What is the characteristic of a localised hot water system?

a)

Water is heated to a specific temperature for domestic use.

b)

Water is heated and/or stored centrally in the building.

c)

Water is heated and/or stored locally to one specific draw-off point area.

d)

Water is heated on demand when hot water outlets are opened.

19.

Which type of centralised hot water system uses a hot water cylinder centrally located in an airing cupboard?

a)

Centralised – stored hot water

b)

Centralised – instantaneous hot water

c)

Decentralised – stored hot water

d)

Decentralised – instantaneous hot water

20.

What type of boiler is used in a centralised instantaneous hot water system?

a)

Combination boiler

b)

Immersion heater

c)

Solar heater

d)

Electric heater

21.

Which type of centralised hot water system is commonly used in smaller domestic properties?

a)

Centralised – instantaneous hot water

b)

Centralised – stored hot water

c)

Decentralised – stored hot water

d)

Decentralised – instantaneous hot water

22.

How is the hot water distributed in both types of centralised hot water systems?

a)

Through the pipework system

b)

Through the electrical system

c)

Through the ventilation system

d)

Through the drainage system

23.

Which type of system is commonly found in older properties but not installed today?

a)

Centralised open vented indirect gravity system

b)

Centralised closed vented direct gravity system

c)

Decentralised open vented indirect gravity system

d)

Decentralised closed vented direct gravity system

24.

What does the primary flow and return from the boiler rely on to transfer heat from the boiler to the cylinder?

a)

Conduction

b)

Convection

c)

Radiation

d)

Evaporation

25.

What type of system is commonly installed today for transferring heat from the boiler to the cylinder?

a)

Centralised open vented indirect pumped primaries

b)

Decentralised closed vented direct pumped primaries

c)

Centralised closed vented direct pumped primaries

d)

Decentralised open vented indirect pumped primaries

26.

How is heat transferred from the boiler to the cylinder in a centralised open vented indirect pumped primary system?

a)

By natural convection

b)

By the use of a pump or circulator through the coil

c)

By direct contact

d)

By radiation

27.

What does the F&E feed in a heating system?

a)

The secondary circuit – hot water distribution

b)

The primary circuit – boiler, cylinder, and F&E

c)

The central heating system

d)

The electrical circuit

28.

What does the CWSC feed in a heating system?

a)

The primary circuit – boiler, cylinder, and F&E

b)

The electrical circuit

c)

The secondary circuit – hot water distribution

d)

The central heating system

29.

Which of the following is a component required by these systems?

a)

Boiler

b)

Air conditioner

c)

Refrigerator

d)

Microwave

30.

What is the function of the primary flow and return pipes in these systems?

a)

To store cold water

b)

To circulate water between the boiler and the heat exchanger

c)

To provide ventilation

d)

To store hot water

31.

Which component is responsible for storing hot water in these systems?

a)

Cold water storage cylinder

b)

Feed and expansion cistern

c)

Hot water cylinder

d)

Open vent pipe

32.

What is the purpose of the feed and expansion cistern in these systems?

a)

To store hot water

b)

To allow for the expansion of water as it heats up

c)

To provide cold water

d)

To circulate water

33.

Which pipe is used to provide cold water to the system?

a)

Hot distribution pipe

b)

Open vent pipe

c)

Cold feed pipe

d)

Heat exchanger coil

34.

What is a characteristic of a direct hot water cylinder system using a boiler?

a)

It uses a heat exchanger coil in the cylinder.

b)

The boiler heats the water that directly comes out of the draw off points.

c)

It does not require a boiler.

d)

The water is heated by solar panels.

35.

What type of system uses electric immersion heaters and has no heat exchanger coil?

a)

Indirect hot water cylinder

b)

Direct hot water cylinder

c)

Solar water heating system

d)

Gas boiler system

36.

How many immersion heaters are used in a direct hot water cylinder system?

a)

One

b)

Two

c)

Three

d)

Four

37.

What do the immersion heaters in a direct hot water cylinder system heat?

a)

The water in the heat exchanger coil

b)

The water in the radiators

c)

The water that directly comes out of the draw-off points

d)

The air in the room

38.

What type of pressure do open vented systems rely on?

a)

High pressure

b)

Low pressure

c)

Medium pressure

d)

Variable pressure

39.

What is the primary function of the vent in an open vented system?

a)

To increase water pressure

b)

To act as a safety relief

c)

To reduce water temperature

d)

To filter the water

40.

Where does the vent pipe from the hot water cylinder terminate in an open vented system?

a)

Over the cold water storage cistern

b)

Under the hot water cylinder

c)

Inside the heating system

d)

Outside the building

41.

What does the vent allow when the system is filled?

a)

Water to flow out

b)

Air to flow out

c)

Water to flow in

d)

Air to flow in

42.

What are the two primary functions of the vent in an open vented system when it is operational?

a)

Heating and cooling

b)

Water filtration and pressure control

c)

Expansion and contraction heating and cooling, and overheating on control failure

d)

Water storage and pressure maintenance

43.

What does BS6700 recommend regarding the capacity of the CWSC feeding a hot water cylinder?

a)

It should be at least half the capacity of the cylinder.

b)

It should be at least double the capacity of the cylinder.

c)

It should be at least the capacity of the cylinder.

d)

It should be at least 1.5 times the capacity of the cylinder.

44.

What is the minimum size of the CWSC if it feeds both hot and cold water?

a)

115 litres

b)

230 litres

c)

150 litres

d)

200 litres

45.

What is the minimum size of the CWSC if it feeds just the hot system?

a)

115 litres

b)

230 litres

c)

150 litres

d)

200 litres

46.

What is the minimum size of the vent pipe?

a)

15mm

b)

22mm

c)

30mm

d)

45mm

47.

Which of the following is not allowed on the vent pipe?

a)

Valve

b)

Elbow joint

c)

T-joint

d)

Coupling

48.

How long should the hot water distribution pipe be before the vent pipe connection?

a)

300mm

b)

450mm

c)

600mm

d)

750mm

49.

According to which standard should the cold feed be sized?

a)

BS6700

b)

BS8000

c)

BS5000

d)

BS9000

50.

What does CWSC need to be for head pressure?

a)

As low as possible

b)

As high as possible

c)

At medium height

d)

At ground level

51.

Where does the cold feed pipe go and what does it have at the lowest point?

a)

To the radiator and has a valve

b)

To the cylinder and has a DOV

c)

To the boiler and has a pump

d)

To the faucet and has a filter

52.

According to BS6700, what should be done if valves are found on the route of the vent pipe?

a)

They should be left as they are.

b)

They should be replaced with new valves.

c)

They should be removed.

d)

They should be painted.

53.

In a direct system, how is the hot water cylinder heated in more modern systems?

a)

By a heat exchanger

b)

By a coil

c)

By immersion heaters

d)

By a boiler

54.

What is absent in a direct hot water cylinder system?

a)

Immersion heaters

b)

Heat exchanger or coil

c)

Water

d)

Boiler

55.

In older direct systems, how was the water heated?

a)

By immersion heaters

b)

By a heat exchanger

c)

By a coil

d)

By the boiler

56.

In an indirect open vented system, what component acts as the heat exchanger to heat the stored water?

a)

External coil

b)

Internal coil

c)

Immersion heater

d)

Primary flow connection

57.

What is a common feature of cylinders in an indirect open vented system?

a)

They have an external coil.

b)

They do not have any immersion.

c)

They normally have a back-up immersion.

d)

They are not used to store water.