Maintenance Inspection Quiz

Total questions: 70

Worksheet time: 35mins

Name
Class
Date
1.

What should be inspected if the flow rate is less than the required manufacturer's instructions or if a customer notices a drop in the flow rate?

a)

Temperature settings on thermostat

b)

Limescale blockages

c)

Filters cleaned

d)

All of the above

2.

Which of the following is NOT listed as a potential cause for poor flow rate?

a)

Temperature settings on thermostat

b)

Limescale blockages

c)

Filters cleaned

d)

Incorrect installation

3.

What is one of the indicators that an inspection is needed for maintenance?

a)

Increase in temperature

b)

Drop in flow rate

c)

Noise from the system

d)

Change in color of the fluid

4.

What can cause unbalanced pressure in manually controlled showers?

a)

Properly balanced pressure

b)

Debris partially blocking the feed pipework

c)

Regular maintenance

d)

Correct temperature settings

5.

Which of the following is NOT listed as a maintenance indicator for showers?

a)

Temperature settings on thermostat

b)

Limescale blockages

c)

Filters cleaned/pipework inspected

d)

Water pressure settings

6.

What can affect the flow rate and temperature in manually controlled showers?

a)

Balanced pressure

b)

Unbalanced pressure due to debris or damaged pipework

c)

Regular use

d)

Proper lubrication of parts

7.

Which maintenance task involves ensuring that the parts move smoothly?

a)

Temperature settings on thermostat

b)

Limescale blockages

c)

Filters cleaned/pipework inspected

d)

Lubrication of parts

8.

What can cause an isolation valve to pass water?

a)

Build-up of limescale

b)

Lack of lubrication

c)

Incorrect installation

d)

Overuse of the valve

9.

Which of the following is NOT a recommended maintenance step for a valve?

a)

Dismantle valve

b)

Remove debris or lime scale

c)

Check seals on shower body

d)

Increase water pressure

10.

What should be done if an isolation valve is old or hasn’t been closed for a period of time?

a)

Replace the entire plumbing system

b)

Inspect and maintain the valve

c)

Ignore the valve

d)

Increase the water flow

11.

What is one of the causes of a valve not closing fully?

a)

Excessive water pressure

b)

Build-up of limescale

c)

Incorrect valve size

d)

Overuse of the valve

12.

Which part of the valve might be damaged, causing it to pass water?

a)

Handle

b)

O ring

c)

Body

d)

Spout

13.

What are some common causes of leaks in components?

a)

Poor installation, corrosion, lack of insulation, freezing, and loosening over time

b)

Overheating, excessive lubrication, and over-tightening

c)

Incorrect material selection, excessive pressure, and lack of maintenance

d)

Overuse, improper storage, and exposure to sunlight

14.

Which of the following is NOT a recommended action to address leaks in components?

a)

Tighten compression fitting nut

b)

Repack glands/O rings

c)

Replace part

d)

Increase pressure

15.

What is one of the maintenance actions mentioned for dealing with leaks?

a)

Increase the temperature

b)

Lubricate parts

c)

Paint the components

d)

Reduce the pressure

16.

What causes expansion noise in hot water or central heating pipework?

a)

The pipes contracting as cold water passes through them

b)

The pipes expanding as heated water passes through them

c)

The pipes vibrating due to water pressure

d)

The pipes rusting over time

17.

Which of the following is NOT a recommended inspection for addressing expansion noise in pipework?

a)

Inspect clips/brackets

b)

Inspect notching

c)

Inspect insulation and padding

d)

Inspect for rust

18.

What is the maximum flow velocity of water to avoid audible noise according to BS6700?

a)

2 m/s

b)

3 m/s

c)

4 m/s

d)

5 m/s

19.

What can be used to reduce noise when cisterns refill?

a)

Increase the pipe diameter

b)

Install a pressure reducing valve

c)

Use collapsible silencers

d)

Decrease the pipe diameter

20.

Which of the following is a method to reduce flow noise in water systems?

a)

Decrease the pipe diameter

b)

Increase the pipe diameter

c)

Increase the water pressure

d)

Use non-collapsible silencers

21.

What is one of the suggested solutions to reduce noise in water systems?

a)

Increase the water temperature

b)

Install a pressure reducing valve

c)

Use a larger cistern

d)

Decrease the water flow

22.

What is a common complaint when the CWSC is refilling after hot water has been used?

a)

Water hammer

b)

Air lock

c)

Low water pressure

d)

Leaking tap

23.

What can cause a juddering sound in the pipework as the FOV shuts off?

a)

Air bubbles

b)

Water hammer

c)

Loose pipe fittings

d)

High water pressure

24.

Which of the following is NOT a suggested action to address water hammer?

a)

Inspect FOV and tap washer

b)

Install flow restrictor

c)

Change to an equilibrium valve

d)

Increase water pressure

25.

What happens if the thermostat fails open?

a)

The customer will have no hot water.

b)

The temperature will continue to rise.

c)

The water will become too cold.

d)

The system will shut down completely.

26.

What is a potential danger if the thermostat fails closed?

a)

The water will become too cold.

b)

The temperature will continue to rise to dangerous levels.

c)

The system will shut down completely.

d)

The customer will have no hot water.

27.

What should be done if the thermostat fails?

a)

Replace the cylinder stat.

b)

Replace the water heater.

c)

Replace the entire system.

d)

Replace the vent.

28.

Which of the following is NOT an indicator of thermostat failure?

a)

No hot water.

b)

Hot water too hot.

c)

Cold water warming up.

d)

Cold water too cold.

29.

What is a common fault in immersion elements in direct cylinders?

a)

Overheating

b)

No hot water

c)

Excessive noise

d)

Water leakage

30.

What is an indicator of immersion element failure?

a)

Water leakage

b)

Excessive noise

c)

Fuse blowing

d)

Overheating

31.

What should be done to fix an immersion element failure?

a)

Replace the cylinder

b)

Replace immersion, complying with Building Regulations Part P

c)

Add more insulation

d)

Increase water pressure

32.

What is a common cause of no hot water in a heating system?

a)

Faulty thermostat

b)

Failure of heat source

c)

Blocked pipes

d)

Low water pressure

33.

What should be checked first if there is no hot water due to a failure of the heat source?

a)

Water pressure

b)

Thermostat settings

c)

Fuse and time clock settings

d)

Radiator valves

34.

Who should be arranged to rectify a boiler issue?

a)

An electrician

b)

A plumber

c)

A Gas Safe engineer

d)

A handyman

35.

What regulation must be complied with when replacing an immersion heater?

a)

Building Regulations part A

b)

Building Regulations part B

c)

Building Regulations part P

d)

Building Regulations part C

36.

What happens if the coil fails in the system described?

a)

The pressure from the CWSC is less than the pressure from the F&E cistern.

b)

Water is forced out of the primary system.

c)

The warning pipe on the F&E discharges.

d)

The hot water remains clear.

37.

What is an indicator of a coil failure in the system?

a)

F&E overflow is not dripping.

b)

Hot water is clear.

c)

F&E overflow is dripping and hot water is discoloured.

d)

The pressure from the CWSC is less than the pressure from the F&E cistern.

38.

What should be done if the coil fails?

a)

Replace the cylinder with a current approved part L cylinder.

b)

Increase the pressure from the CWSC.

c)

Decrease the pressure from the F&E cistern.

d)

Clean the warning pipe on the F&E.

39.

What is a consequence of losing the air bubble in a single feed cylinder?

a)

The hot water will be discoloured when drawn off.

b)

The pressure relief valve will discharge when the water is heated.

c)

The system will not need draining.

d)

The air bubble will automatically reinstate.

40.

What happens with the unvented cylinder when the water is heated and the air bubble is lost?

a)

The hot water will be discoloured when drawn off.

b)

The pressure relief valve will discharge.

c)

The system will not need draining.

d)

The air bubble will automatically reinstate.

41.

What is the first step to reinstate the air bubble in both single feed and unvented cylinders?

a)

Refill the system.

b)

Drain the secondary system to the base of the hot water cylinder.

c)

Replace the hot water cylinder.

d)

Heat the water.

42.

What should be done after draining the secondary system to reinstate the air bubble?

a)

Replace the hot water cylinder.

b)

Heat the water.

c)

Refill the system.

d)

Discharge the pressure relief valve.

43.

What is a sign that water is boiling in a heating system?

a)

The water is lukewarm when drawn off.

b)

There is no steam in the loft area.

c)

The open vent is discharging and water is dangerously hot when drawn off.

d)

The water is cold when drawn off.

44.

What should be done if old immersion heater thermostats are found?

a)

They should be left as they are.

b)

They should be replaced with new immersions that contain a non self-resetting thermal cut out.

c)

They should be replaced with the same old immersions.

d)

They should be disconnected permanently.

45.

What happens if a cylinder stat fails?

a)

The water will stop heating immediately.

b)

The water will continue to heat and be controlled by the boiler stat, which should cut out at approximately 80-85ºC.

c)

The water will cool down automatically.

d)

The water will be controlled by the immersion heater.

46.

What is one reason cold water can warm up according to the document?

a)

Cold water pipes are too far from hot water pipes.

b)

Cold water pipes are too close to hot water pipes.

c)

Cold water pipes are made of metal.

d)

Cold water pipes are not insulated.

47.

How should hot water pipes be installed to avoid the transfer of heat to cold water pipes?

a)

Below cold water pipes.

b)

Parallel to cold water pipes.

c)

Above cold water pipes.

d)

Inside cold water pipes.

48.

What should be done to hot water pipes to avoid heat loss?

a)

They should be painted.

b)

They should be insulated.

c)

They should be made of plastic.

d)

They should be buried underground.

49.

What happens if the hot water cylinder overheats?

a)

The vent pipe discharges into the CWSC.

b)

The cold water pipe bursts.

c)

The hot water pipe freezes.

d)

The hot water pipe leaks.

50.

According to BS8000 pt15, where should the hot pipe be installed in relation to the cold pipework?

a)

Below the cold pipework.

b)

Inside the cold pipework.

c)

Above the cold pipework.

d)

Parallel to the cold pipework.

51.

What is a common cause of air locks in low pressure systems?

a)

Incorrect installation of pipework

b)

High water pressure

c)

Vertical pipework

d)

Properly installed pipework

52.

What is an indicator of air locks in a pipework system?

a)

Continuous water flow

b)

No flow of water or intermittent water flow

c)

High water pressure

d)

Steady water pressure

53.

What is a suggested solution to prevent air locks in pipework?

a)

Increase water pressure

b)

Install pipework correctly

c)

Use vertical pipework

d)

Decrease water pressure

54.

What is a common cause of blockages in a system that affects the flow rate at draw off points?

a)

Excessive water pressure

b)

Debris in the system

c)

Low water temperature

d)

Incorrect pipe size

55.

What needs to be done at the commissioning stage to prevent blockages?

a)

Increase water pressure

b)

Reduce water temperature

c)

Flush out the system to remove debris

d)

Install larger pipes

56.

What is an indicator of a blockage in the system?

a)

High water pressure

b)

Restricted water flow

c)

Noisy pipes

d)

Leaking valves

57.

Which of the following is NOT a recommended action to address blockages?

a)

Remove and clean filters

b)

Trace draw off points and pipework to locate blockage

c)

Increase water temperature

d)

Remove and replace

58.

What is a common issue in hard water areas that can cause blockages and reduce efficiency?

a)

Rust

b)

Limescale

c)

Algae

d)

Mold

59.

Which of the following is an indicator of limescale buildup?

a)

Increased water flow

b)

Clear water

c)

Reduced water flow

d)

Soft valves

60.

What is a recommended solution to prevent limescale buildup?

a)

Install a water filter

b)

Install a water softener or scale inhibitor

c)

Use hot water only

d)

Clean with vinegar

61.

When dealing with faults in maintenance, which of the following should you check first?

a)

Software updates

b)

Temperature settings

c)

User manuals

d)

Warranty status

62.

Which of the following is NOT listed as a basic check for faults in maintenance?

a)

Timer settings

b)

Fuse

c)

Water treatment

d)

Software compatibility

63.

What is one of the basic checks for faults in maintenance related to electrical components?

a)

Timer settings

b)

Water treatment

c)

Fuse

d)

Insulation

64.

Which of the following is a basic check for faults in maintenance related to plumbing?

a)

Temperature settings

b)

Water treatment

c)

Timer settings

d)

Insulation

65.

In the context of maintenance, what should be checked to ensure proper installation and connections?

a)

Timer settings

b)

Water treatment

c)

Fuse

d)

Installation and connections

66.

What can cause maintenance problems in plumbing systems?

a)

Soft water

b)

Temporary hard water

c)

Distilled water

d)

Rainwater

67.

What happens when hard water is heated above 65°C?

a)

It becomes soft water

b)

It loses its calcium and limescale is formed

c)

It evaporates completely

d)

It becomes acidic

68.

What is one of the effects of limescale in plumbing systems?

a)

It purifies the water

b)

It insulates the water from the heat source

c)

It makes the water taste better

d)

It increases water pressure

69.

What is another effect of limescale in plumbing systems?

a)

It can cause blockages

b)

It can clean the pipes

c)

It can increase water flow

d)

It can reduce water temperature

70.

What should ideally be done to hard water before it enters a domestic water system?

a)

It should be boiled

b)

It should be treated

c)

It should be filtered

d)

It should be cooled