Feed and Expansion (F&E) Cistern Quiz

Total questions: 63

Worksheet time: 32mins

Name
Class
Date
1.

What is the main purpose of the Feed and Expansion (F&E) cistern in an open vented system?

a)

To store cold water for household use

b)

To allow the heated water in the system to expand and to operate at atmospheric pressure

c)

To filter impurities from the water

d)

To heat the water in the system

2.

Where is the Feed and Expansion (F&E) cistern commonly located in an open vented system?

a)

In the basement

b)

In the kitchen

c)

In the loft

d)

In the garden

3.

At what level should the base of the Feed and Expansion (F&E) cistern be placed?

a)

Above the cold water storage cistern

b)

Below the cold water storage cistern

c)

At the same level as the cold water storage cistern

d)

At ground level

4.

What is the function of the Feed and Expansion (F&E) cistern in an open vented system?

a)

To fill the system up with water

b)

To drain the system

c)

To cool the water in the system

d)

To circulate the water in the system

5.

What is the common capacity of the Feed and Expansion (F&E) cistern?

a)

10 litres

b)

18 litres

c)

22 litres

d)

15 litres

6.

Where is the 15mm cold feed located in relation to the F&E cistern?

a)

Above the F&E

b)

Below the F&E

c)

To the side of the F&E

d)

Inside the F&E

7.

What is the minimum height the 22mm open vent from the primaries must rise above the water level?

a)

300mm

b)

450mm

c)

500mm

d)

600mm

8.

How far above the circulator should the F&E be located?

a)

0.5 metres

b)

1 metre

c)

1.5 metres

d)

2 metres

9.

What does the rising main supply in the F&E system?

a)

BS 1212 FOV

b)

Cold feed exit

c)

Service valve

d)

Expansion tank

10.

Why must there be a service valve installed prior to the FOV?

a)

To allow for maintenance

b)

To increase water pressure

c)

To reduce water temperature

d)

To prevent water leakage

11.

At what level should the water set by the FOV in the cistern be?

a)

High level

b)

Medium level

c)

Low level

d)

Overflow level

12.

What percentage does the system water expand by when heated?

a)

2%

b)

4%

c)

6%

d)

8%

13.

What is the primary function of the open vent pipe?

a)

To increase the water pressure

b)

To provide a safety outlet and allow the system to operate at atmospheric pressure

c)

To reduce the temperature of the system

d)

To filter the water in the system

14.

Why should the open vent not have any valves attached?

a)

It would increase the water flow

b)

It could have disastrous effects if the valve was closed and the cold feed became blocked

c)

It would decrease the system's efficiency

d)

It would cause the system to overheat

15.

What is the minimum height the vent needs to be above the water level?

a)

300mm

b)

350mm

c)

450mm

d)

500mm

16.

What is the minimum pipe size for the open vent pipe?

a)

18mm

b)

20mm

c)

22mm

d)

24mm

17.

What is the primary function of an air separator in a piping system?

a)

To heat the water

b)

To cool the water

c)

To separate the air from the water

d)

To filter impurities from the water

18.

What allows close proximity or close coupled pipework when positioning the cold feed and vent pipe?

a)

A water pump

b)

An air separator

c)

A heat exchanger

d)

A pressure valve

19.

What is the basic structure of an air separator?

a)

A small pipe with a heating element

b)

An oversized pipe with a cold feed and vent pipe connections

c)

A narrow pipe with multiple filters

d)

A large tank with a cooling system

20.

What happens to the water inside the air separator?

a)

It gets heated

b)

It gets cooled

c)

It swirls around, separating the air

d)

It gets filtered

21.

What is one of the benefits of the correct layout of pipework and removal of air from the system?

a)

Increases the noise in the system

b)

Reduces the noise in the system

c)

Increases the risk of corrosion

d)

Increases the temperature of the system

22.

What does the removal of air from the system help to lower?

a)

The temperature of the system

b)

The pressure in the system

c)

The risk of corrosion

d)

The flow rate of the system

23.

What is the function of an air separator in a pipework system?

a)

To increase the temperature of the system

b)

To ensure correct coupling of the cold feed and vent pipes

c)

To increase the noise in the system

d)

To decrease the flow rate in the system

24.

What is commonly used instead of an air separator in the configuration described?

a)

T frame

b)

H frame

c)

L frame

d)

X frame

25.

Where should the vent and the cold feed be installed in relation to the boiler?

a)

On the return side of the circulator

b)

On the flow from the boiler, on the suction side of the circulator

c)

On the flow from the boiler, on the discharge side of the circulator

d)

On the return side of the boiler, on the suction side of the circulator

26.

What is the maximum distance allowed between the vent and the cold feed?

a)

100mm

b)

150mm

c)

200mm

d)

250mm

27.

What is the purpose of ensuring that the circulator always draws on the cold feed?

a)

To increase the temperature of the water

b)

To ensure proper circulation

c)

To prevent air from entering the system

d)

To reduce the pressure in the system

28.

What ensures the neutral point of the system is at the base of the cold feed in an air separator and H frame?

a)

The correct layout of pipework

b)

The type of pump used

c)

The temperature of the water

d)

The size of the boiler

29.

What is the primary purpose of positioning the pump correctly in a circulator system?

a)

To reduce the system's temperature

b)

To produce positive pressure and avoid air entering the system

c)

To increase the system's noise

d)

To decrease the system's efficiency

30.

According to the golden rule, where must the circulator always draw from?

a)

The hot feed

b)

The cold feed

c)

The middle feed

d)

The return feed

31.

Why is it important to set the speed settings of the circulator correctly?

a)

To allow the system to cool down efficiently

b)

To allow the system to heat up efficiently without any system noise

c)

To increase the system's noise

d)

To decrease the system's pressure

32.

Where is the circulator located in a heating system?

a)

By the radiators

b)

By the pump flanges

c)

By the boiler

d)

By the thermostat

33.

What materials are used for washers to maintain the watertight seal in a circulator?

a)

Metal or plastic

b)

Rubber or fibre

c)

Wood or metal

d)

Plastic or fibre

34.

What can be done to remove the pump without draining the system?

a)

Turn off the boiler

b)

Close the full bore valves at either side of the flanges

c)

Disconnect the radiators

d)

Open the pressure release valve

35.

What could be the reason if the radiators are not heating up and the hot water is only lukewarm?

a)

A faulty thermostat

b)

A sluggish or poor performing pump

c)

A broken radiator

d)

Low water pressure

36.

What is the function of the isolation valves integral to the flanges on either side of the pump?

a)

To increase the pressure of the pump

b)

To allow easy maintenance

c)

To reduce the noise of the pump

d)

To control the temperature of the pump

37.

Why is the position of the circulator important in a system that requires positive pressure?

a)

To ensure the system operates under negative pressure

b)

To maintain the correct relation to the cold feed and vent pipe

c)

To reduce the temperature of the system

d)

To increase the flow rate of the system

38.

What happens when the system is under negative pressure?

a)

Pumping over the vent pipe

b)

Pushing into the cistern

c)

Correct arrangement showing the position of the vent and feed behind the pump

d)

Increasing the temperature of the system

39.

What is the correct arrangement for a system under positive pressure?

a)

Pumping over the vent pipe

b)

Pushing into the cistern

c)

Position of the vent and feed behind the pump

d)

Increasing the temperature of the system

40.

What is another name for a two port motorised valve?

a)

Zone valve

b)

Pressure valve

c)

Flow valve

d)

Temperature valve

41.

What does a zone valve allow to be controlled separately?

a)

Cold water and the cooling circuits

b)

Hot water and the heating circuits

c)

Air flow and the ventilation circuits

d)

Electrical current and the power circuits

42.

What happens when there is a call for heat in a system with a zone valve?

a)

The zone valve closes

b)

The zone valve opens

c)

The thermostat shuts down

d)

The boiler stops working

43.

What occurs when the thermostat reaches the set temperature in a system with a zone valve?

a)

The zone valve opens

b)

The zone valve closes

c)

The boiler starts heating

d)

The water flow increases

44.

What does the three port mid-position valve control?

a)

The flow of water to both the heating and hot water circuits

b)

The flow of air to both the heating and cooling circuits

c)

The flow of gas to both the heating and cooling circuits

d)

The flow of electricity to both the heating and cooling circuits

45.

Which of the following is NOT a label for the three ports of the three port mid-position valve?

a)

AB

b)

A

c)

B

d)

C

46.

What does the port labeled 'A' control in the three port mid-position valve?

a)

Flow for the boiler

b)

Central heating

c)

Hot water

d)

Cold water

47.

What does the port labeled 'B' control in the three port mid-position valve?

a)

Flow for the boiler

b)

Central heating

c)

Hot water

d)

Cold water

48.

What does the port labeled 'AB' control in the three port mid-position valve?

a)

Flow for the boiler

b)

Central heating

c)

Hot water

d)

Cold water

49.

What is the function of a three port mid-position valve in a heating system?

a)

To allow water to circulate around both heating and hot water circuits

b)

To shut off water flow completely

c)

To only allow water to circulate around the heating circuit

d)

To only allow water to circulate around the hot water circuit

50.

In the heating only position, which port is shut off in a three port mid-position valve?

a)

Port A

b)

Port B

c)

Port AB

d)

None of the ports

51.

In the central heating only position, which port is shut off in a three port mid-position valve?

a)

Port A

b)

Port B

c)

Port AB

d)

None of the ports

52.

Where is the cylinder thermostat typically situated on a hot water cylinder?

a)

At the bottom of the cylinder

b)

One-third of the way up the cylinder

c)

At the top of the cylinder

d)

In the middle of the cylinder

53.

What is the primary function of the cylinder thermostat?

a)

To control the water pressure

b)

To govern the temperature of the hot water

c)

To regulate the flow of water

d)

To measure the water level

54.

To what is the cylinder thermostat linked?

a)

The main water supply

b)

The heating element

c)

The zone valve or three port valve

d)

The water pump

55.

What types of cylinder thermostats are mentioned in the text?

a)

Digital and analog

b)

Bi-metallic strip, volatile liquid, or gas type

c)

Mechanical and electronic

d)

Single-phase and three-phase

56.

What is the common maximum temperature setting for a cylinder thermostat?

a)

40°C

b)

50°C

c)

60°C

d)

70°C

57.

Where should a room thermostat be situated?

a)

1.5 metres up a wall and approximately 3 metres away from a heat source

b)

1 metre up a wall and approximately 2 metres away from a heat source

c)

2 metres up a wall and approximately 1 metre away from a heat source

d)

3 metres up a wall and approximately 1.5 metres away from a heat source

58.

What type of room thermostat is more commonly fitted nowadays?

a)

Basic bi-metallic type

b)

Programmable, Wi-Fi, app-activated and digital type

c)

Compensating room thermostat

d)

Manual thermostat

59.

Which of the following is NOT a type of room thermostat mentioned in the text?

a)

Basic bi-metallic type

b)

Programmable type

c)

Digital type

d)

Solar-powered type

60.

Where is the boiler thermostat located?

a)

On the heat exchanger

b)

On the hot water cylinder

c)

On the boiler

d)

On the heat emitters

61.

What does the boiler thermostat govern?

a)

The temperature of the heat exchanger

b)

The temperature of the primary water

c)

The temperature of the heat emitters

d)

The temperature of the return pipe

62.

What is heated by the primary water controlled by the boiler thermostat?

a)

The heat emitters only

b)

The return pipe only

c)

The heat exchanger and heat emitters

d)

The phial attached to the boiler

63.

What is commonly attached to the return pipe of the boiler?

a)

A heat exchanger

b)

A hot water cylinder

c)

A phial

d)

A heat emitter