1.

What is the difference between high-density racks and conventional racks?

a)

High density > 10 KW, conventional < 10 KW

b)

High density < 10 KW, conventional > 10 KW

c)

High density uses more space, conventional uses less space (assuming the same total IT MW target)

d)

High density uses less power, conventional uses more power (assuming power per rack)

2.

What are the challenges of building a data center in the Netherlands compared to Indonesia?

a)

Permits for building data centers in the Netherlands are stricter than in Indonesia in terms of environmental issues

b)

In the Netherlands, there is winter which can be used for free cooling (less power used)

c)

The cost of electricity and water in Indonesia is cheaper than in the Netherlands.

d)

All answers are correct.

3.

What consultancy services does Royal HaskoningDHV offer for data centers?

a)

PMCM

b)

Design Engineering

c)

Special studies (ETAP and CFD)

d)

All answers are correct.

4.

How can Royal HaskoningDHV contribute to the development of future data centers?

a)

Design sustainable data centers

b)

Efficient cooling systems

c)

Considering AI requirements in the design

d)

All answers are correct.

5.

Which of the following statements is correct?

a)

Design sustainable data centers

b)

Design a data center with a raised floor.

c)

Design a data center without a raised floor.

d)

Depends on client requirements.

6.

Which cooling system is better?

a)

Cooling system with CRAH units

b)

Cooling system with FWU

c)

Cooling system with liquid immersion

d)

Depends on client requirements.

7.

Which fact about data center that not true?

a)

Data Center design should follow Uptime Tier regulations

b)

In the future data center power usage should be more efficient

c)

Data Center physical security should be highly secure

d)

Engineering Design is the key to achieve Highly Efficient Data Center

8.

How can we improve the PUE value?

a)

Optimize the cooling system.

b)

Re-evaluate power requirements in the IT data hall.

c)

Upgrade existing equipment.

d)

Answers A and C are correct.

9.

Which system is most suitable for a green data center?

a)

Painting the walls green

b)

Providing many green plants in the data center environment

c)

Using renewable energy

d)

Answers B and C are correct.

10.

How many years has Royal HaskoningDHV Indonesia been established?

a)

>50 years

b)

<50 years

c)

Just established.

d)

0 years

11.

Which of these training programs are held at Nusantara Data Center Academy?

a)

Data Center Technician

b)

Data Center Design Awareness

c)

Data Center Specialist

d)

All of the above

12.

What is the name of Nusantara Academy’s YouTube channel?

a)

Nusantara Academy

b)

Podcast Nusantara

c)

Nusantara Podcast

d)

Nusantara Podcast Academy

13.

What topics are discussed in the most recent episode of Podcast Nusantara?

a)

Data Center Construction

b)

Green Data Center

c)

Data Center Sales & Marketing

d)

Renewable Energy for Data Centers

14.

Which of these polytechnics has Nusantara Academy collaborated with?

a)

ATMI Polytechnic

b)

META Polytechnic

c)

Takumi Polytechnic

d)

All of the above

15.

What are the latest events held by Nusantara Academy?

a)

Connect Fest

b)

Nusantara Data Center and Cloud Summit

c)

Nusantara Executive Dinner Gathering

d)

Nusantara Sustainability Forum