WorksheetsSingle Phase Electrical Installation
Total questions: 56
Worksheet time: 28mins
Which of the following equipment is not found in the distribution fuse board?
Main switch
Neutral link
Miniature circuit breaker (MCB)
Residual current circuit breaker (RCCB)
What is the function of the Kilo Watt Hour Meter?
Measure current used
Measure voltage used
Measure resistance used
Measure total energy used
What type of testing is shown in Figure Q3?
Continuity test
Insulation test
Polarity test
Earthing test
What is the function of a measuring tape?
Cutting cables
Making measurements
Making connections
Winding conductors
Earth leakage current can be protected using?
RCCB
Pull switch
Two-way switch
Leakage stopper
What is the supply voltage for single-phase residential homes in Malaysia?
240 V
415 V
500 V
150 V
What is the minimum cable size and fuse rating for a ring circuit?
1.5mm² pvc/pvc - 6 Amp
2.5 mm² pvc/pvc - 15 Amp
2.5 mm² pvc/pvc - 32 Amp
1.25 mm² pvc/pvc - 32 Amp
Which of the following is not a type of cable?
PVC
MICC
XLPE
ACC
The testing tool 'Ohm meter' is used to measure?
Current
Voltage
Power
Resistance
How many terminals does an intermediate switch have?
1 terminal
2 terminals
3 terminals
4 terminals
Which quantity cannot be measured by a multimeter?
Current
Voltage
Power
Resistance
What is the function of the 'lead strip cutter' tool?
Cutting cables
Shaping solder
Twisting cable conductors
Tightening screws on switch terminals
What is the MCB size used for 2 socket outlets in a radial circuit?
6 A
16 A
20 A
32 A
The statement 'This type of trunking requires the earth conductor connection to be terminated on its body' can be associated with?
PVC casing
PVC trunking
Mini trunking for office installations
Trunking coated with zinc
'Stock and dies' are used to make threads on?
PVC pipe
PVC conduit
Metal conduit
Flexible conduit
According to IEE regulations, the allowed space factor for trunking is?
45%
40%
60%
55%
Choose the correct statement for the installation of SSO circuit 15 A.
Number Rate MCB
2 20A
1 20A
1 32A
1 6A
How many terminals does an RCCB have?
2
3
1
4
Why are circuit breakers placed on each circuit with different current ratings?
To protect the load used.
To protect the circuit when leakage current occurs.
To protect the circuit breaker from damage.
To protect the circuit when excess current occurs.
What conditions can cause the MCB to trip?
Earth leakage cable
Earth and phase cable connected
Earth and neutral cable connected
Phase and neutral cable connected
What is the space factor for conduit to make single phase wiring?
25%
30%
35%
40%
What are the advantages of concealed wiring?
Neat and beautiful
Longer cable durability
Reduced mechanical damage
Easy to maintain when cable damage occurs
What is the color code for electrical wiring?
Blue
Orange
Red
Gray
The standard notice displaying the word __________ must be placed in a visible location near the switchboard.
WARNING
DANGER
NO ENTRY
WORKING PERSONNEL
What does the 'OFFSET' bend on conduit mean?
Single 90° angle bend
Single 135° angle bend
Double 90° angle bend
Double 135° angle bend
What tool is used to bend PVC conduit?
Table vice
Bending machine
Wood bending block
Bending spring
What is the name of the tool mentioned above?
Elbow
Long Bend
2 Way Box
Inspection Tee
What is the nominal voltage for single phase and its range?
230V +10% -6%
230V +10% -5%
230V +6% -10%
230V +5% -10%
The statement refers to?
Space factor
Economic factor
Various factors
Reduction factor
Why must PVC/PVC cables be used for concealed wiring?
To look neater
According to the homeowner's request
Surroundings and mechanical damage
PVC/PVC cables are cheap and readily available
What is the color code for trunking in electrical wiring?
Blue
Orange
White
Red
What is the cable size for lighting circuit wiring in trunking?
1.5 mm² PVC
2.5 mm² PVC
3.0 mm² PVC
4.0 mm² PVC
What is the cable size and MCB rating for S.A.K 13Amp for trunking circuit wiring?
2.5 mm² PVC - 6 Amp
2.5 mm² PVC - 10 Amp
2.5 mm² PVC - 32 Amp
2.5 mm² PVC - 30 Amp
What is the minimum cable size for trunking wiring for S.A.K 15 Amp?
6.0 mm² PVC
4.0 mm² PVC
4.0 mm² PVC/PVC
1.25 mm² PVC/PVC
What are the advantages of trunking wiring system?
High cost
Easy to maintain
Does not require skilled workers
Can accommodate many cables
What is the space factor for trunking?
30%
35%
40%
45%
What tool is used to cut trunking?
Trunking cutter
Trunking spring
Trunking bander
Trunking saw
The following are tools commonly used in trunking work EXCEPT
Saw
L-shaped square
Saddle & bar
Trunking scissors
What are the disadvantages of trunking wiring system?
High cost
Durable
Not neat/beautiful
Requires skilled workers
The common size of trunking used for single phase wiring is?
1" X 2"
2" X 2"
2" X 3"
2" X 4"
What is the common trunking size used for single phase wiring?
1" X 2"
2" X 2"
2" X 3"
2" X 4"
What is the rating of MCB for wiring 6 socket outlets (Ring Circuit)?
6 Amp
16 Amp
20 Amp
32 Amp
What is the operating current of RCD for commonly used power circuits?
10mA
20mA
30mA
40mA
Why must cables be marked during wiring?
According to the supervisor's instructions
To differentiate cables
To facilitate work completion at terminals
To ease repair work in case of damage
What is the nominal voltage required for single phase installation?
230V
250V
400V
500V
Which of the following is NOT a common size of current rating and sensitivity of RCD?
63A/0.3A
40A/100mA
40A/300mA
32A/100mA
What testing device is used to measure earth electrode resistance?
Multimeter
RCCB tester
Insulation tester
Earth Resistance tester
What happens when there is a leakage current to earth in a circuit?
Earth leakage circuit breaker trips
Voltage drop occurs in the circuit
Fuse blows when supply is connected
Earth leakage circuit breaker connects the circuit directly
What type of earth electrode is commonly used for single phase supply houses?
Aluminum strip
Galvanized pipe
Copper rod
Copper tape
Which of the following are methods to reduce earth electrode resistance EXCEPT?
Spreading iron powder
Watering with salt water
Planting electrodes in parallel
Planting electrodes closely together
What is the most suitable cable size for surface wiring of lighting circuits?
1.5 mm² pvc
2.5 mm² pvc
1.5 mm² pvc/pvc
2.5 mm² pvc/pvc
What is the cable size and fuse rating for 2 S.A.K 13Amp for surface wiring ring circuit?
2.5 mm² pvc - 6 Amp
2.5 mm² pvc - 20 Amp
2.5 mm² pvc/pvc - 32 Amp
2.5 mm² pvc/pvc - 20 Amp
What is the cable size and MCB rating for S.A.K 13 Amp for surface wiring ring circuit?
2.5 mm² pvc/pvc - 6 Amp
2.5 mm² pvc/pvc - 10 Amp
2.5 mm² pvc/pvc - 32 Amp
2.5 mm² pvc/pvc - 20 Amp
What is the minimum cable size suitable for surface wiring for S.A.K 15 Amp?
4.0 mm² pvc
4.0 mm² pvc/pvc
6.0 mm² pvc/pvc
1.25 mm² pvc/pvc
Why must pvc/pvc type cables be used for surface wiring?
To look neater
According to the homeowner's requirements
Pvc/pvc cables are cheap and readily available
It is exposed to surrounding conditions and mechanical damage
Which of the following is NOT categorized as an additional tool?
Cable
Ceiling rose
Socket outlet
Lamp holder