WorksheetsFire Code Quiz
Total questions: 30
Worksheet time: 15mins
Fires involving cloth and rubber.
Class A
Class B
Class C
Class D
Class K
Building contents that are liable to produce a considerable volume of smoke in case of fire but will not cause explosions or produce poisonous fumes.
Low hazard contents
Moderate hazard
High hazard contents
Very high hazard contents
Non-explosive contents
Who must witness the testing and commissioning of the fire protective and warning system?
The Fire Marshall
The Fire Safety Inspector
The Plan Evaluator
The Chief of the FSES
The Building Official
Fires involving sodium.
Class A
Class B
Class C
Class D
Class K
Based on the occupancy classifications in the Fire Code, dry and wet markets are classified as:
Business
Mercantile
Industrial
Special Structures
Mixed
Fires involving flammable liquids and gases.
Class A
Class B
Class C
Class D
Class K
A system of vertical pipes to which firehoses can be attached on each floor.
Standpipe system
Automatic fire suppression system
Sprinkler system
Riser
Fire detection and alarm system
A building is considered high-rise in the Fire Code when it is ___ meters of more in height.
10
15
30
40
50
This person is tasked with the review of the plans and the specifications to determine the design's compliance with the Fire Code and other life and safety standards.
Building Official
Plan Evaluator
Fire Safety Inspector
Chief of the FSES
Fire Marshall
Fire safety inspection not required for:
Certificate of Occupancy
Business Permit
Building Permit
It is required for all of the above
Both A and B
Which is required for the Building Permit?
FSIC
FSEC
FALAR 3
FSMR
FSCCR
Which is required for the issuance of the FSIC for Occupancy?
FSIC
FSMR
FSCR
FSCCR
FALAR 2
If after the building plan review, the plans are disapproved, the Fire Marshall will not issue the FSEC. What will he/she issue instead?
FALAR 1
Notice of Disapproval
Notice to Comply
FSIC
FSMR
Minimum width of a door opening in a means of egress.
710mm
810mm
900mm
910mm
1220mm
Which types of operations are required to undergo business inspection?
a. Industrial operations
b. Commercial or business operations
c. Residential occupancies
A, B, and C
A and B only
The following are typically included in this report: as-built plans, testing certificates, and certification that the building complies with the requirements of the Fire Code.
a. FSCR
b. FSIC
c. FSCCR
d. FSMR
Both C and D
Which is not an occupancy classification in the Fire Code?
Assembly
Storage
Institutional
Mercantile
All of these are occupancy classifications in the Fire Code
The three parts of the means of egress.
Exit access, exit, exit discharge
Exit access, exit, public way
Exit, protective enclosure, public way
Protective enclosure, exit access, exit discharge
None of these
Maximum length of a dead end, according to the Fire Code.
5 meters
6 meters
8 meters
10 meters
46 meters
How many means of egress at the minimum are required for a floor level that will be occupied by 1,000 people?
1
2
3
4
5
According to the Fire Code, if two exits are required, what is the required minimum distance between them? Assume that the building has no sprinkler system.
Length of maximum overall diagonal of the building divided by 2
Length of maximum overall diagonal of the building divided by 3
Length of maximum overall diagonal of the building divided by 4
1/5 of the perimeter of the area served
1/2 of the perimeter of the area served
Minimum tread depth required by the Fire Code for existing stairs.
200mm
230mm
250mm
280mm
300mm
Minimum width required for new stairs serving an occupant load of 49.
710mm
915mm
1015mm
1120mm
1420mm
Which handrail mounting height is prohibited by the Fire Code for stairways?
760mm
785mm
865mm
All of these are prohibited
None of these is prohibited
Occupant load factor of in-patient healthcare treatment facilities, according to the Fire Code
9.30 sqm/person
11.10 sqm/person
18.60 sqm/person
22.30 sqm/person
33.10 sqm/person
Occupant load factor of residential occupancies, according to the Fire Code
9.30 sqm/person
11.10 sqm/person
18.60 sqm/person
22.30 sqm/person
33.10 sqm/person
Minimum illumination required for the means of egress.
8.50 lux
10.70 lux
12.30 lux
14.60 lux
All of these are acceptable levels of illumination
According to the Fire Code, the minimum width of a ramp that is used as a component in a means of egress
1,120 mm
1,200 mm
1,220 mm
1,400 mm
1,420 mm
What is the required fire resistance rating of an exit enclosure if the exit connects 5 levels?
30 minutes
1.00 hour
1.50 hours
2.00 hours
3.00 hours
When was the IRR of the Fire Code revised?
2008
2010
2015
2019
2020