wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

National Plumbing Code - Definitions Part 2

Total questions: 67

Worksheet time: 34mins

Name
Class
Date
1.

The extended portion of a pipe that is closed at one end to which no connections arc made on the extended portion, thus permitting the stagnation of liquid or air therein.

a)

Blind Pipe

b)

Dead-end

c)

Closed Branch

d)

Stub-out

2.

The Administrative Authority and includes any other law enforcement agency concerned by any provision of this Code, whether such agency is specifically named or not.

a)

Compliance Office

b)

Code Enforcement Unit

c)

Department having jurisdiction

d)

Regulatory Authority

3.

The length of a pipe along its centerline and fittings.

a)

Developed Length

b)

Centerline Distance

c)

Connection Length

d)

Total Length

4.

Unless specifically stated, the term "diameter'' is the nominal diameter as designated commercially. I. D. denotes ________________ of pipe and O.D. denotes ________________ of tube.

a)

Inside Diameter; Outside Diameter respectively

b)

Internal Diameter; Outer Dimension respectively

c)

Inner Depth; Outer Depth respectively

d)

Interior Diameter; External Diameter respectively

5.

The liquid and water-home wastes derived from the ordinary living processes, free from industrial wastes and of such character that permit satisfactory disposal without special treatment. It is discharged into the public sewer or into a private sewage disposal system.

a)

Industrial Sewage

b)

Domestic Sewage

c)

Household Wastewater

d)

Community Sewage

6.

A pipe fitting with adjacent reverse bends and shaped like the letter "S''

a)

S-Trap Fitting

b)

Double-bend Fitting

c)

Loop Fitting

d)

Reverse Bend Adapter

7.

Two offsets in succession or in series such that the centerlines of the outside ends are in the same straight line.

a)

Stacked Offset

b)

Parallel Offset

c)

Double Offset

d)

Series Offset

8.

The vertical portion of a rainwater conductor .

a)

Downspout

b)

Gutter Drop

c)

Rain Stack

d)

Storm Pipe

9.

A pipe, which carries ground and surface waters, storm water or wastewater into a building drainage system

a)

Conduit

b)

Drain

c)

Collector

d)

Outlet

10.

Includes all the pipings within public or private premises which convey sewage or other liquid wastes to a legal point of disposal but does not include the mains of a public sewer system or a public sewage treatment or disposal plant.

a)

Private Sewer

b)

Sanitary Network

c)

Drainage System

d)

Wastewater Network

11.

A vent that does not carry liquid or water-borne wastes.

a)

Dry Vent

b)

Dual Vent

c)

Waste Vent

d)

Wet Vent

12.

A term used to describe soil or waste system where all pipings are of threaded pipe, tubing or other such rigid construction using recessed drainage fittings to correspond to the types of piping.

a)

Threaded Pipe Network

b)

Rigid Drainage System

c)

Recessed Drainage System

d)

Durham System

13.

The minimum cross-sectional area at the point of water supply discharge measured or expressed in terms of:

( 1) diameter of a circle;

(2) if the opening is not circular, the diameter of a circle of equivalent cross-sectional area.

(This is applicable also to air gap installation.)

a)

Cross-Sectional Area

b)

Effective Opening

c)

Utilization Opening

d)

Flow Opening

14.

The on-going installation of the plumbing system or any part thereof which has been installed prior to the effectivity of this Code.

a)

Current Installation

b)

Legacy Installation

c)

Existing Work

d)

Established Work

15.

One person living alone or a group living together, whether related to each other by birth or not.

a)

Family

b)

Household

c)

Domestic Unit

d)

Residence

16.

A valve located at the end of a water pipe through of which water can be drawn from or held within the pipe.

a)

Gate Valve

b)

Tap

c)

Spigot

d)

Faucet

17.

A metallic sleeve, caulked or joined to an opening in a pipe, into which a plug is screwed that can be removed for cleaning or examining the interior of the pipe.

a)

Cap

b)

Ferrule

c)

Cleanout Plug

d)

Threaded Sleeve

18.

A receptacle other than a trap attached to a plumbing system in which water or wastes may be collected or retained for ultimate discharge into the plumbing system.

a)

Water Closet

b)

Fixture

c)

Appurtenance

d)

Device

19.

The water supply pipe between the fixture supply pipe and the water-distributing pipe .

a)

Fixture Branch

b)

Supply Line

c)

Fixture Line

d)

Connection Pipe

20.

The drainpipe from the trap of a fixture to the junction of that drain with any other drainpipe.

a)

Waste Pipe

b)

Drain Connection

c)

Fixture Drain

d)

Drain Branch

21.

A water supply pipe connecting the fixture with the fixture branch.

a)

Supply Pipe

b)

Fixture Supply

c)

Water Line

d)

Branch Supply

22.

An arbitrary quantity in terms of which the load­ producing effect's or water requirements on the plumbing system of different kinds of plumbing fixtures are expressed in some arbitrarily chosen scale.

a)

Load Factor

b)

Water Demand Metric

c)

Fixture Unit

d)

Plumbing Unit

23.

Equivalent to a rate of flow at 28.3 liters per minute ( l cu. ft ./minute).

a)

One plumbing unit

b)

One fixture unit

c)

Usage Rate

d)

Flow Rate

24.

The level in a fixture at which water begins to overflow over the top or rim of the fixture.

a)

Flood Level

b)

Spill Level

c)

Overflow Point

d)

Rim Height

25.

The top edge of a receptacle from where water overflows

a)

Flood level rim

b)

Flood level

c)

Overflow Edge

d)

Receptacle Lip

26.

A fixture is flooded when the liquid therein rises to the flood level rim

a)

Overflowed

b)

Filled

c)

Flooded

d)

Engorged

27.

The area included within surrounding walls of a building (or portion thereof), exclusive of vent shafts and courts.

a)

Floor Area

b)

Usable Space

c)

Interior Area

d)

Living Space

28.

A tank located above or integral with water closet, urinal or similar fixtures for flushing or removing excrements in the fixture.

a)

Flush Valve

b)

Flush Tank

c)

Flushometer Valve

d)

Flushometer Tank

29.

A device located at the bottom of the tank for the purpose of flushing waster closet and similar fixtures.

a)

Flush Valve

b)

Flush Tank

c)

Flushometer Valve

d)

Flushometer Tank

30.

Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into

fixtures for flushing purposes.

a)

Flush Valve

b)

Flush Tank

c)

Flushometer Valve

d)

Flushometer Tank

31.

A device, which discharges a predetermined quantity of water into fixtures for flushing purposes and is actuated by direct .

water pressure.

a)

Flush Valve

b)

Flush Tank

c)

Flushometer Valve

d)

Flushometer Tank

32.

A valve in which the flow of water is cut off by means of a circular disc fitted against machine-smoothed faces, at right angles to the direction of flow. The disk is raised or lowered by means of a threaded stern connected to the handle of the valve. The opening in the valve is usually as large as the full bore of the pipe.

a)

Gate Valve

b)

Globe Valve

c)

Check Valve

d)

Backwater Valve

33.

A valve in which the flow of fluid is cut off by means of a circular disc that fits over and against the horizontal valve seat. The movement of the plane of disc is parallel to the normal direction of flow of water through the orifice resulting to a tortuous passage which offers a high pressure loss.

a)

Gate Valve

b)

Globe Valve

c)

Check Valve

d)

Backwater Valve

34.

A return bend of small-sized pipe, one end of which is about 30 cm long and the other end is about 7. 5 cm long. It is commonly used as a faucet for a pantry sink. Also, the term means the flexible tubing connection between a service pipe and a water main.

a)

Faucet

b)

Gooseneck

c)

Swan Neck

d)

Curved Connector

35.

The slope or fall of a line of pipe with reference to a horizontal plane. In drainage, it is usually expressed as the fall in centimeters per meter or percentage slope of pipe.

a)

Pitch

b)

Angle of Incline

c)

Grade

d)

Slope Ratio

36.

An interceptor of at least 3 cubic meters capacity to serve one or more fixtures and which is remotely located.

a)

Waste Interceptor

b)

Fat Trap

c)

Grease Trap

d)

Grease Interceptor

37.

A device designed to retain grease from one to a maximum of tour fixtures.

a)

Grease Trap

b)

Grease Interceptor

c)

Fat Trap

d)

Waste Interceptor

38.

The water that stands in or passes through the ground.

a)

Surface Water

b)

Subsurface Water

c)

Ground Water

d)

Aquifer Water

39.

A branch vent that performs its functions for two (2) or more traps.

a)

Dual Vent

b)

Loop Vent

c)

Group Vent

d)

Circuit Vent

40.

The vertical distance from the "Grade Line" to the highest point of the coping of a flat roof or to the top line of a mansard roof or to the average height of the highest gable of a pitch or hip-roof.

a)

Vertical Clearance

b)

Building Height

c)

Building Elevation

d)

Roof Height

41.

A drain pipe extending laterally from a soil or waste stack or building drain with or without vertical sections or branches, which receives the discharge from one or more fixture drains and conducts it to the soil or waste stack or to the building drain.

a)

Soil Pipe

b)

Horizontal Branch

c)

Building Drain

d)

Building Sewer

42.

Any pipe or fitting installed in a horizontal position or which forms an angle of not more than forty-five (45) degrees

with the horizontal plane.

a)

Soil Pipe

b)

Horizontal Branch

c)

Horizontal Pipe

d)

Building Sewer

43.

A part of the lowest horizontal piping of a plumbing system which receives the discharges from soil, waste and other drainage pipes inside of a building and conveys it to the house sewer outside of the

building.

a)

Building Sewer

b)

House Drain

c)

House sewer

d)

Horizontal Pipe

44.

The part of a plumbing system extending from the house drain at a point 0.60 meters from the outside face of the foundation wall of a building to the junction with the street sewer or to any point of discharge, and conveying the drainage of one building site.

a)

Horizontal Branch

b)

House Drain

c)

House sewer

d)

Horizontal Pipe

45.

The pipeline from the building to the public or street storm drainage system.

a)

House Sewer

b)

House Storm Sewer

c)

Waste Pipe

d)

Soil Pipe

46.

Cast iron soil pipes with plain ends connected together with bolted stainless steel bands and neoprene gaskets.

a)

Hubless Pipes

b)

Bell and Spigot

c)

Threaded Pipes

d)

Sleeve Joint Pipe

47.

A pipe that does not connect directly with the drainage system but conveys liquid wastes by discharging into a plumbing fixture, interceptor or receptacle directly connected to the drainage system .

a)

Soil Pipe

b)

Building Drain

c)

Indirect Waste Pipe

d)

Discharge Pipe

48.

A pipe installed to vent a fixture trap and which connects with the vent system above the fixture served or terminates in the

open air.

a)

Individual vent

b)

Common Vent

c)

Loop Vent

d)

Yoke Vent

49.

Any and alI liquid or water-borne waste from industrial or commercial processes, except domestic sewage.

a)

Commercial Waste

b)

Industrial Waste

c)

Common Waste

d)

Residential Sewage

50.

What does I.P.S. mean?

a)

Internal Pipe Size

b)

Industrial Pipe Standard

c)

Iron Pipe Size

d)

Integrated Pipe Size

51.

A condition contrary to sanitary principles or injurious to health.

a)

Polluted

b)

Insanitary

c)

Contaminated

d)

Unhygienic

52.

A device designed and installed to separate and retain deleterious, hazardous or undesirable matters from normal wastes and permits normal sewage or liquid wastes to discharge into the disposal terminal by gravity.

a)

Interceptor

b)

Debris Collector

c)

Filter Chamber

d)

Clarifier

53.

The lowest portion of the interior part of any pipe or conduit that is not vertical.

a)

Invert

b)

Channel Bed

c)

Bottom Grade

d)

Pipe Trough

54.

The Administrative Authority under the Department of Health, the Department of Public Works & Highways, the Department of Interior and Local Government, t he City Mayors of Chartered Cities, Environmental Management Bureau (D.E.N.R) and other government: entities that regulate the practice of Registered & Licensed Master

Plumbers.

a)

Governing Authority

b)

Jurisdiction

c)

Compliance Office

d)

Regulatory Body

55.

Equipment or materials bearing a label of a listing agency.

a)

Tagged

b)

Labeled

c)

Marked

d)

Identified

56.

In plumbing, a secondary pipeline. In sewerage, a common sewer to which no other branch sewer is connected. It receives sewage from building sewer service connections only.

a)

Lateral

b)

Fixture Branch

c)

Circuit Pipe

d)

Latrine

57.

A water closet consisting of a continuous trough containing water. The trough extends under two or more adjacent seats. Prohibited by health authorities for permanent installations.

a)

Privy

b)

Latrine

c)

Privy vault

d)

Sanitary Station

58.

A fixture designed for the washing of the hands or face. Sometimes called a wash basin.

a)

Lavatory

b)

Water Closet

c)

Bidet

d)

Bathtub

59.

A cesspool that is not watertight.

a)

Absorption Pit

b)

Leaching Cesspool

c)

Drainage Well

d)

Percolation Cesspool

60.

A pipe connected from building gutter to the downspout or conductor.

a)

Drain Pipe

b)

Collection Pipe

c)

Gutter Downspout

d)

Leader

61.

Measured along it s centerline

a)

Diameter of Pipe

b)

Development Length

c)

Length of Pipe

d)

Total Length of Pipe

62.

The discharge from any fixture, appliance or appurtenance in connection with a plumbing system which does not receive

fecal matter.

a)

Liquid Waste

b)

Industrial Waste

c)

Common Waste

d)

Domestic Waste

63.

Equipment or materials included in a List published by a listing agency that maintain periodic inspection on current production of listed equipment or materials and whose listing state either that the equipment or materials complied with approved standards or have been tested and found suitable for use in specified manners.

a)

Certified

b)

Listed

c)

Validated

d)

Registered

64.

An agency accepted by the Administrative Authority in the business of listing nr labeling and which maintains a periodic inspection program on current production of listed models, and makes available a published report of such listing where specific information is included tint the product has been tested against approved standards and found safe for use in a specific manner.

a)

Certification Body

b)

Inspection Authority

c)

Regulatory Agency

d)

Listing Agency

65.

A pipe or shaft to convey foul air from a plumbing fixture or a room to the outer air.

a)

Air vent

b)

Individual Vent

c)

Local Vent

d)

Group Vent

66.

A vertical vent connection on a horizontal soil or waste pipe branch at a point downstream of the last fixture connection and turning to a horizontal line above the highest overflow level of the highest fixture connected thereat; the terminus connected to the stack vent in the case of loop venting or to the vent stack nearby in the case of circuit venting.

a)

Loop Vent

b)

Local Vent

c)

Group Vent

d)

Wet Vent

67.

A single area of land legally recorded or validated by other means acceptable to the Administrative Authority where a building is situated or site of any work regulated by this Code, together with the yard, court, and unoccupied space legally required for the building or works; and which is owned by or in the lawful possession of the owner of the building or works.

a)

Lot

b)

Plot

c)

Site

d)

Parcel