Heating System Quiz

Total questions: 46

Worksheet time: 23mins

Name
Class
Date
1.

Which British Standard covers the method for the calculation of design heating loads?

a)

BS EN 12828:2003

b)

BS EN 12381:2003

c)

BS EN 14336:2004

d)

BS EN 1264-1:1998

2.

What is the measurement of the U-value? Remember this measurement for your exam!

a)

w/m2K

b)

kj/moC

c)

w/kg/K

d)

J/m3/K

3.

What is the correct formula to determine the heat loss from a space through air changes and ventilation? Remember this formula for your exam!

a)

m2 x Δt x 1.33

b)

m2 x Δt x U-value

c)

m3 x QTY x Δt x 0.33

d)

m3 x U-value x QTY x 3

4.

What are the likely effects of oversizing a heating system?

a)

Reduced energy usage, as systems produce enough heat quickly before shutting off for longer periods

b)

Reduced life expectancy of heat emitters, which often overheat due to higher temperatures

c)

Greater risk of burns/scalds, due to excess temperatures within the system and increased boiler combustion efficiency

d)

Reduced energy efficiency, as boilers ‘hunt’, and greater initial outlay costs

5.

What is the most suitable external design temperature for a house with normal sheltered exposure in England and Wales?

a)

-1oC

b)

-3oC

c)

-4oC

d)

-5oC

6.

What is the correct formula to determine the heat loss through a surface such as a wall or window? Remember this formula for your exam!

a)

m2 x Δt x 1.33

b)

m2 x Δt x U-value

c)

m3 x QTY x Δt x 0.33

d)

m3 x U-value x QTY x 3

7.

A radiator has a temperature of 70oC at the inlet and 50oC at the outlet. What is the maximum water temperature of the radiator?

a)

20oC

b)

40oC

c)

50oC

d)

60oC

8.

You are trying to determine the correct size of an expansion vessel for a typical domestic central heating system. The system is installed in 22mm and 15mm copper. Which of the following methods could be used to give an approximate system volume?

a)

2 litres per kW of the boiler

b)

4 litres per kW of the boiler

c)

6 litres per kW of the boiler

d)

10 litres per kW of the boiler

9.

What is the term given to the radiator within a central heating system which is the furthest from the heat source?

a)

The content circuit

b)

The shunt circuit

c)

The hydraulic circuit

d)

The index circuit

10.

What is the formula used to determine the flow rate for a circuit? Remember this formula for your exam!

a)

kg/s = kW / 4.19 x Δt

b)

W = kg x SHC x Δt

c)

kW = 4.19 / kg x 1.33

d)

Litres = kW x SHC / Δt

11.

According to BSEN 14336:2004, what is the minimum test pressure and period for a water-based heating system?

a)

At least 30% greater than the working pressure for a minimum of one hour

b)

At least 30% greater than the working pressure for a minimum of two hours

c)

At least 1.5 times the working pressure for three hours

d)

At least 2 times the working pressure for one hour

12.

What is the purpose of a hot flush of the central heating system?

a)

To remove excess limescale deposits from the system

b)

To ensure that the system flow rates can be achieved throughout the installation

c)

To remove traces of the legionella bacteria from the system pipework

d)

To remove excess jointing compounds, fluxes and oils from the system

13.

What is not an effect of good balancing within a central heating system?

a)

Increased efficiency at the boiler

b)

Reduced fuel costs

c)

More even radiator temperatures

d)

Higher calorific value of the fuel

14.

Which component is initially used to balance the heat outputs at radiators?

a)

Wheel head valves

b)

TRVs

c)

Lockshield valves

d)

Pump speed controller

15.

A radiator has stopped working and is completely cold. All the other radiators in the system are hot and no air is present in the cold radiator. What is the most likely problem?

a)

Pin stuck within TRV

b)

Sludge blocking parts of the radiator

c)

Faulty pump

d)

System needs balancing

16.

Which of the following components can be used to check the charge pressure of an expansion vessel?

a)

Pressure gauge at the boiler when the system is hot

b)

Tyre pressure gauge when the system is hot and the vessel full

c)

Pressure gauge on the boiler when the system is cold

d)

Tyre pressure gauge with the vessel disconnected from the central heating system

17.

A central heating boiler fires on demand for heating. The flame is established for a second or two before 'locking out'. What is the most likely fault?

a)

Ignition electrode failed

b)

Rectification probe failed

c)

Air pressure switch stuck in the open position

d)

Gas valve solenoid burned out

18.

A customer reports that she needs to top up the boiler regularly but cannot see any signs of leakage. All pipework from the combination boiler is visible and no signs of leaks are present. You have noticed signs of water at the pressure relief valve discharge pipe outlet. What is the most likely cause of the pressure loss?

a)

Boiler pressure gauge is malfunctioning

b)

Both check valves at the external filling loop are passing and the system is backflowing into the cold main

c)

The cylinder coil has failed, leading to central heating water leaking into the secondary water

d)

The expansion vessel has ruptured

19.

You have been called to an old open vented system which has a pumped heating circuit and a gravity hot water circuit. The radiators are cold but the hot water is hot, despite the controller being switched to heating and hot water. No zone valves are installed. What is the most likely cause of the fault?

a)

Failure of boiler thermostat

b)

Failure of circulating pump

c)

Failure of synchron motor

d)

Failure of cylinder thermostat

20.

What heating system uses a difference in the density of water to circulate heat to a hot water cylinder?

a)

Y plan

b)

Gravity fed

c)

S plan+

d)

Hypocaust

21.

The conservation of fuel and energy is covered by which approved document?

a)

Building regulations part P

b)

Building regulations part M

c)

Building regulations part H

d)

Building regulations part L

22.

What is the main purpose of a central heating system?

a)

To heat up the core of the building

b)

To provide thermal comfort to a property

c)

To supply heating to a single room

d)

To provide heat to a number of properties

23.

What is at the highest point of a vented heating system?

a)

Expansion vessel

b)

Feed and expansion cistern

c)

Cold feed isolation valve

d)

Automatic air vent

24.

What is the primary function of the open vent on a central heating system?

a)

To allow the system to pressurise

b)

To allow the system to operate at atmospheric pressure

c)

To provide sufficient oxygen to the heating system

d)

To provide a means of ventilation when filling the system

25.

What type of heating system incorporates a three-port valve that gives priority to the hot water system?

a)

S plan

b)

S plan+

c)

Y plan

d)

W plan

26.

What three components are required when converting an open vented system with a sealed system?

a)

Automatic air vent, low loss header, filling loop

b)

Filling loop, expansion vessel, pressure gauge

c)

Pressure relief valve, filling loop, expansion vessel

d)

Expansion vessel, automatic air vent, pressure gauge

27.

What type of heating system charges using low-cost off-peak tariffs?

a)

District

b)

Electric storage

c)

Y plan

d)

Warm air

28.

What type of heating system can be split into zones that serve a cluster of houses and buildings?

a)

District

b)

Underfloor

c)

Microbore

d)

Thermosyphon

29.

Which one of the following Building Regulations discusses the control of heating systems within new-build dwellings?

a)

Part L1a

b)

Part L1b

c)

Part L2a

d)

Part L2b

30.

Which one of the following describes the purpose of background heating?

a)

Heat the property quicker than full central heating

b)

Heat only certain rooms in the property, as required

c)

Heat the property to a lower temperature than full central heating

d)

Heat the property to a higher temperature than full central heating

31.

An automatic bypass valve is activated by which of the following?

a)

Boiler shutting off

b)

Programmer being switched on

c)

Pressure created within the system

d)

Pressure of the incoming water service

32.

The main reason a radiator should be installed 150mm above floor level is to?

a)

Reduce the risk of fire

b)

Allow the heat to circulate

c)

Protect the flooring from possible leaks

d)

Allow easier access for maintenance work

33.

A thermostatic radiator valve opens and closes as a result of the temperature of the?

a)

Primary circuit

b)

Boiler

c)

Space it’s installed in

d)

Return pipework

34.

A pump should be positioned so that the heating system is operating under?

a)

No pressure

b)

Positive pressure

c)

Negative pressure

d)

Both positive and negative pressures

35.

An automatic air vent should be positioned at the?

a)

Highest part of the system

b)

Lowest point of the system

c)

Point where the vent enters the system

d)

Point where the cold feed enters the system

36.

Which one of the following central heating systems uses a manifold?

a)

One-pipe system

b)

Two-pipe system

c)

Microbore system

d)

Gravity pipe system

37.

Installing an air separator allows which one of the following to take place?

a)

Close coupling of the cold feed and vent connections

b)

Close coupling of the flow and return connections

c)

Close coupling of the pump and the vent connections

d)

Close coupling of the motorised valve connections

38.

The minimum size for an open vent pipe is?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

39.

Which one of the following is the best installation position for a cylinder thermostat?

a)

¾ down from the top of the cylinder

b)

⅓ down from the top of the cylinder

c)

¼ up from the bottom of the cylinder

d)

⅓ up from the bottom of the cylinder

40.

Which port is the central heating flow connected to on a mid-position valve?

a)

A

b)

B

c)

AB

d)

BA

41.

In a central heating installation, the primary pipework connects the?

a)

Boiler and the cylinder

b)

Cylinder and the outlets

c)

Cylinder and the radiators

d)

Feed cistern and the cylinder

42.

Condensing boilers are specifically designed to?

a)

Provide stored hot water

b)

Extract less heat from the flue gases

c)

Extract more heat from the flue gases

d)

Provide hot water at low temperatures

43.

By which one of the following processes do radiators give out 70% of their heat?

a)

Conduction

b)

Convection

c)

Radiation

d)

Emission

44.

Separate space heating zones are required in dwellings where the floor area is greater than?

a)

150m²

b)

180m²

c)

200m²

d)

500m²

45.

Which one of the following types of valve would you commonly find in a Y-plan system with no bypass?

a)

Three-port diverter valve

b)

Zone valve

c)

Two-port valves

d)

Three-port mid-position valve

46.

A district heating system is feeding a number of high-rise flats. Hydraulic separation is required – how is this achieved within each flat?

a)

Heat recovery unit

b)

Ground source heat pump

c)

Heat interface unit

d)

Air source heat pump