wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

215 ppt5 Types of Shower Mixer Valves

Total questions: 13

Worksheet time: 7mins

Name
Class
Date
1.

What are the three types of shower mixer valves mentioned in the document?

a)

Gravity mixer, Mains-fed/boosted mixer, Electric instantaneous

b)

Pressure mixer, Manual mixer, Digital mixer

c)

Thermostatic mixer, Manual mixer, Electric mixer

d)

Gravity mixer, Pressure mixer, Digital mixer

2.

What type of system does a cistern-fed/gravity mixer rely on for pressure?

a)

High-pressure system

b)

The head height of the CWSC

c)

Medium-pressure system

d)

Variable-pressure system

3.

What is the safest valve to use in a cistern-fed/gravity mixer?

a)

Pressure relief valve

b)

Ball valve

c)

Thermostatic valve

d)

Check valve

4.

What does the sensing device in a thermostatic valve do?

a)

Heats the water

b)

Expands and contracts

c)

Filters the water

d)

Changes water color

5.

What is the relationship between shower head location and water level in a negative head system?

a)

Shower head height is above or within 1m of the height of the CWSC

b)

Shower head height is 3m below the height of the CWSC

c)

Shower head height is in a different building to the CWSC

d)

Shower head height is not related to the height of the CWSC water level

6.

What type of pump is required if the flowrate is insufficient?

a)

Positive head pump

b)

Negative head pump

c)

bicycle pump

d)

Submersible pump

7.

What is the key component that causes the pump to operate in positive head showers?

a)

Flow switch

b)

Pressure valve

c)

Thermostat

d)

Pump

8.

Which shower system is most suitable for homes with a high water tank?

a)

Positive head showers

b)

Negative head showers

c)

Electric showers

d)

Mixer showers

9.

In what situations can negative head pumps be used?

a)

Positive-head, negative-head, and whole-house

b)

Only positive-head

c)

Only negative-head

d)

Only whole-house

10.

What is the starting point of a negative head in relation to the CWSC?

a)

600mm below

b)

600mm above

c)

300mm below

d)

300mm above

11.

What is the main advantage of negative head pumps in terms of noise?

a)

They are quieter

b)

They are louder

c)

They have no noise

d)

They have variable noise levels

12.

What type of situations do negative head pumps not require?

a)

Natural head or flow of water

b)

High pressure

c)

Low temperature

d)

Large volume

13.

Where is the instantaneous electric shower fed from?

a)

Cold water tank

b)

Incoming main

c)

Hot water cylinder

d)

Rainwater collection system