312 - Electrical circuits and components

Total questions: 52

Worksheet time: 26mins

Name
Class
Date
1.

What are the typical electrical circuits found in a modern dwelling?

a)

Ring main, Lighting, Power circuit (radial)

b)

Solar panel, Wind turbine, Battery storage

c)

Generator, Transformer, Inverter

d)

Circuit breaker, Fuse, Resistor

2.

How many ring mains are typically found in a modern dwelling?

a)

1

b)

2

c)

3

d)

4

3.

Where are the lighting circuits typically located in a modern dwelling?

a)

Both upstairs and downstairs

b)

Only in the kitchen

c)

Only in the living room

d)

Only in the basement

4.

What might the power circuits in a modern dwelling be used for?

a)

Cooker, central heating, and alarm

b)

Television, radio, and computer

c)

Refrigerator, microwave, and dishwasher

d)

Washing machine, dryer, and vacuum cleaner

5.

What do consumer units house for radial and ring final circuits?

a)

Individual MCBs

b)

Circuit breakers

c)

Fuses

d)

Transformers

6.

What is incorporated in consumer units to provide protection against earth leakage?

a)

RCD

b)

Fuse

c)

Circuit breaker

d)

Transformer

7.

As of 2019, what material must all newly installed consumer units be made of?

a)

Metallic

b)

Plastic

c)

Wood

d)

Ceramic

8.

What protects the consumer unit in a circuit protective device setup?

a)

Single pole isolator

b)

Double pole main isolator

c)

Circuit breaker

d)

Fuse

9.

How are the MCBs split in the circuit protective device setup?

a)

In a single bank

b)

In three banks

c)

In two banks

d)

Randomly

10.

What does each bank of MCBs have for protection?

a)

Its own fuse

b)

Its own RCD

c)

Its own circuit breaker

d)

Its own isolator

11.

What types of circuits do the MCBs protect?

a)

Only lighting circuits

b)

Only power circuits

c)

Ring final circuits, lights, and power circuits

d)

Only ring final circuits

12.

What does an RCBO combine the functions of?

a)

An MCB and a fuse

b)

An RCD and a fuse

c)

An MCB and an RCD

d)

A circuit breaker and an isolator

13.

What is the purpose of the earth bar in a consumer unit?

a)

To connect the live wires

b)

To provide a path to ground for electrical safety

c)

To distribute the neutral current

d)

To control the circuit breakers

14.

Which component in a consumer unit is responsible for distributing the incoming live current?

a)

Neutral bar

b)

Earth bar

c)

Live in

d)

Busbar

15.

In a consumer unit, what is the function of the busbar?

a)

To connect the earth wires

b)

To distribute electrical power to circuit breakers

c)

To measure electrical current

d)

To provide a neutral connection

16.

What is the primary function of circuit protective devices like MCBs?

a)

To increase the voltage in a circuit

b)

To permanently isolate circuits in an over-current situation

c)

To decrease the current in a circuit

d)

To provide power to the circuit

17.

What does MCB stand for?

a)

Main Circuit Board

b)

Miniature Circuit Breaker

c)

Maximum Current Breaker

d)

Main Current Blocker

18.

What is a typical use for a 6A MCB?

a)

Heating circuits

b)

Lighting circuits

c)

Motor circuits

d)

Cooling circuits

19.

What is the maximum operating current for a residual current device (RCD)?

a)

10mA

b)

20mA

c)

30mA

d)

40mA

20.

What happens when an RCD detects an imbalance in the circuit?

a)

The circuit continues to operate normally.

b)

The circuit is automatically disconnected.

c)

The current is increased.

d)

The voltage is reduced.

21.

How quickly should an RCD disconnect to protect a 32A circuit?

a)

0.2s

b)

0.4s

c)

0.6s

d)

0.8s

22.

What is the role of an RCD in the event of failure of basic protection?

a)

It provides additional protection.

b)

It reduces the voltage.

c)

It increases the current.

d)

It disconnects the power supply permanently.

23.

What is the function of the fuse in older fuse boards?

a)

To create the circuit from the copper busbar to the individual circuit

b)

To provide power to the entire building

c)

To regulate the voltage in the circuit

d)

To act as a backup power source

24.

Where are the fuses inserted in older fuse boards?

a)

Into the slots on an exposed busbar

b)

Directly into the power outlet

c)

Into a separate fuse box

d)

Into the main power switch

25.

What is a characteristic of a cartridge fuse to BS 1361?

a)

It is cheaper than semi-enclosed fuses.

b)

It is fitted into a consumer unit like a rewireable fuse.

c)

It cannot be replaced incorrectly.

d)

It is used only in industrial settings.

26.

What is a disadvantage of cartridge fuses compared to semi-enclosed fuses?

a)

They are less reliable.

b)

They are more expensive.

c)

They are harder to install.

d)

They have a lower current rating.

27.

What does the wire diameter in a semi-enclosed fuse to BS 3036 relate to?

a)

The voltage rating.

b)

The physical size of the fuse.

c)

The current rating.

d)

The temperature rating.

28.

What type of cables are generally flat PVC two-core and earth, depending on the circuit they feed?

a)

Flex cables

b)

Multicore flex

c)

Singles cables

d)

Consumer unit cables

29.

Where are flex cables often found?

a)

In consumer units

b)

On individual appliances

c)

In boiler controls

d)

In gas solenoids

30.

What is a possible use for multicore flex cables?

a)

Connecting a gas solenoid

b)

Wiring boiler or heating controls

c)

Feeding consumer units

d)

Protecting with a conduit

31.

What type of cables may be used with mechanical protection such as a conduit?

a)

Flex cables

b)

Multicore flex

c)

Singles cables

d)

PVC two-core cables

32.

What is the typical use of flex cables?

a)

For underground wiring

b)

For extension cables and leads for appliances above floor level

c)

For outdoor lighting

d)

For automotive wiring

33.

Why is the correct selection of flex important?

a)

To reduce cost

b)

To prevent overheating

c)

To improve signal quality

d)

To increase flexibility

34.

What is the wattage capacity for a 1.0mm cable ?

a)

700w

b)

1400w

c)

2400w

d)

3600w

35.

Which appliance is suitable for a 0.75mm cable?

a)

Lights

b)

Central heating

c)

Kettle/immersion

d)

Commercial

36.

What is the primary use of armoured cable?

a)

To connect household appliances

b)

To supply an incoming mains or outhouse with power

c)

For internal wiring in homes

d)

To connect to portable devices

37.

What additional feature does the metal armour of the cable provide?

a)

Electrical insulation

b)

Aesthetic appeal

c)

Mechanical protection

d)

Heat resistance

38.

What type of appliances use heat-resistant flex?

a)

Refrigerators

b)

Kettles

c)

Televisions

d)

Computers

39.

What is the typical power rating for an immersion heater that uses heat-resistant flex?

a)

1.0–1.5kW

b)

2.5–3.0kW

c)

3.5–4.0kW

d)

4.5–5.0kW

40.

What is the maximum temperature that heat-resistant flex can withstand without damage?

a)

65°C

b)

75°C

c)

85°C

d)

95°C

41.

What is the typical capacity in amps for a 1.5mm twin and earth (CPC) cable?

a)

11A

b)

14A

c)

18A

d)

25A

42.

Which domestic usage is a 6.0mm twin and earth (CPC) cable typically used for?

a)

Lighting

b)

Sockets

c)

Shower

d)

Cooker

43.

What is the fuse rating range for a 2.5mm twin and earth (CPC) cable?

a)

6-10 amps

b)

16-20 amps

c)

30-32 amps

d)

45 amps

44.

According to the table, which cable size is used for cookers?

a)

1.0mm

b)

2.5mm

c)

6.0mm

d)

10mm

45.

What is the primary use of back boxes (pattress boxes) and joint boxes in electrical installations?

a)

To decorate walls

b)

To fix fascias or outlets and securely join cables

c)

To increase electrical current

d)

To reduce noise

46.

Which of the following is an example of a back box?

a)

Galvanised steel single recessed back box

b)

Wooden frame box

c)

Metal conduit box

d)

Plastic cable tie

47.

What material is used for a plastic surface mounted single back box?

a)

Wood

b)

Metal

c)

Plastic

d)

Glass

48.

Which type of box is used for heating control installations?

a)

Galvanised steel single recessed back box

b)

Wiring centre box

c)

Plastic surface mounted jointing boxes

d)

Bakerlite plastic jointing boxes

49.

What is the purpose of fascias in electrical installations?

a)

To provide lighting

b)

To serve as a switch plate or outlet

c)

To generate electricity

d)

To cool down electrical devices

50.

Which of the following is a type of fascia with a neon indicator?

a)

Plastic fan isolator switch

b)

Pull cord switch for shower

c)

Plastic unswitched fused spur

d)

Brushed steel single switched socket outlet

51.

Identify the fascia type used for controlling a shower.

a)

Plastic switched fused spur

b)

Pull cord switch

c)

Cooker switch with socket outlet

d)

Brushed steel single switched socket outlet

52.

What is the purpose of using adapters in electrical fittings?

a)

To enhance the aesthetic appearance of cables

b)

To ensure a secure connection and prevent disconnection or abrasion

c)

To increase the length of the cables

d)

To reduce the electrical resistance of the cables