Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

PPT 6 Electrical Supplies and Equipment Identification Quiz

Total questions: 40

Worksheet time: 20mins

Name
Class
Date
1.

What is the minimum current and voltage combination that can be lethal to a human?

a)

50 milliamps and 50 volts

b)

100 milliamps and 100 volts

c)

10 milliamps and 10 volts

d)

200 milliamps and 200 volts

2.

Which factors affect the lethality of electricity?

a)

Age, body mass, and health

b)

Height, weight, and diet

c)

Temperature, humidity, and altitude

d)

Speed, distance, and time

3.

What is the typical supply voltage in a dwelling that makes electricity dangerous?

a)

230 volts

b)

110 volts

c)

50 volts

d)

400 volts

4.

What should be considered before carrying out any electrical task?

a)

The cost of the equipment

b)

The relevance of PPE for the task

c)

The color of the tools

d)

The brand of the tools

5.

What is recommended for electrical work to offer protection in case of faults?

a)

Non-insulated tools

b)

Insulated screwdrivers and tools

c)

Metal tools

d)

Wooden tools

6.

What does the use of insulated tools NOT mean?

a)

You are expected to work on live equipment

b)

You have protection in case of faults

c)

You should follow risk assessments

d)

You need to consider general PPE

7.

What should be considered for tasks involving pipework systems?

a)

The color of the pipes

b)

The general PPE suitable to the environment

c)

The length of the pipes

d)

The brand of the pipes

8.

According to the Electricity at Work Regulations, what must be done to circuits on which engineers work?

a)

Circuits should be made dead.

b)

Circuits should be left live.

c)

Circuits should be partially live.

d)

Circuits should be disconnected.

9.

When is live work on circuits permitted according to the regulations?

a)

When it is not practical for the circuit to be dead.

b)

When it is convenient for the engineer.

c)

When the circuit is new.

d)

When the circuit is old.

10.

What does the rule about testing imply regarding working on live circuits?

a)

Engineers cannot work on live circuits just because it is inconvenient to turn off the supply.

b)

Engineers can work on live circuits if they are in a hurry.

c)

Engineers can work on live circuits if they have permission.

d)

Engineers can work on live circuits if they are experienced.

11.

Before isolating a circuit, what should be checked regarding others?

a)

They are not affected by the electrical isolation

b)

They are aware of the circuit design

c)

They have the necessary tools

d)

They are wearing protective gear

12.

What should be ensured about essential plant and equipment before isolating a circuit?

a)

They are turned off

b)

They are not affected

c)

They are labeled

d)

They are disconnected

13.

What should be done for people who may be affected by electrical isolation?

a)

Provide them with a map

b)

Give them enough warning

c)

Offer them training

d)

Supply them with tools

14.

What type of temporary equipment should be supplied if necessary during electrical isolation?

a)

Mobile heaters and battery powered lighting

b)

Generators and transformers

c)

Circuit breakers and fuses

d)

Insulated gloves and boots

15.

What is the first step in the safe electrical isolation procedure?

a)

Test the voltage tester

b)

Identify the circuit

c)

Lock off the supply

d)

Post notices in appropriate places

16.

Why is it important to ensure that the test circuit is dead?

a)

To save time

b)

To prevent electrical shock

c)

To increase voltage

d)

To reduce noise

17.

What should be done after locking off the supply in the safe electrical isolation procedure?

a)

Identify the circuit

b)

Test the voltage tester

c)

Keep the key with you

d)

Isolate the circuit

18.

Which of the following is NOT part of the safe electrical isolation procedure?

a)

Make sure the test voltage instrument works

b)

Ensure the test circuit is dead

c)

Increase the circuit voltage

d)

Post notices in appropriate places

19.

What is the first step in the safe electrical isolation procedure?

a)

Prove the device is working on a proving unit

b)

Locate and identify circuit or appliance

c)

Select an approved voltage indicating device

d)

Identify means of isolation

20.

What should you do if the voltage indicator is not working on a known supply?

a)

Begin work

b)

Replace or repair

c)

Identify means of isolation

d)

Fit warning cables if required

21.

How can you ensure isolation during the procedure?

a)

By switching off

b)

By increasing voltage

c)

By connecting to a live circuit

d)

By using a higher voltage device

22.

Which standard must the test meter be approved to?

a)

HSE GS38

b)

ISO 9001

c)

ANSI Z535

d)

OSHA 1910

23.

What type of equipment is recommended for testing without the need for a battery?

a)

Dedicated voltage indicator

b)

Multimeter

c)

Electrical indicator screwdriver

d)

Digital voltmeter

24.

Why are electrical indicator screwdrivers not approved?

a)

They are too expensive

b)

They are not reliable

c)

They have potential for incorrect measurement

d)

They require a battery

25.

Why is it important to prove a test instrument before use?

a)

To ensure it is safe and reliable

b)

To save time during testing

c)

To avoid using a manual

d)

To increase the instrument's lifespan

26.

What should be used to prove a test instrument is working properly?

a)

A multimeter

b)

A proving unit

c)

A battery tester

d)

A circuit breaker

27.

How can an engineer test if an instrument is functioning properly?

a)

By checking the battery level

b)

By inserting the probes into the test points

c)

By turning the instrument on and off

d)

By reading the instruction manual

28.

What is the first step in isolating a circuit or appliance?

a)

Identifying the correct circuit or appliance

b)

Turning off the main power supply

c)

Checking the voltage levels

d)

Consulting the user manual

29.

What might be required if the circuit or appliance is in service?

a)

A safety inspection

b)

Permission

c)

A new circuit breaker

d)

A voltage check

30.

What does each MCB in a consumer unit serve?

a)

A shared circuit

b)

A dedicated circuit

c)

Multiple circuits

d)

A temporary circuit

31.

What needs to be established after identifying the circuit?

a)

The voltage level

b)

The means of isolation

c)

The circuit diagram

d)

The power consumption

32.

What is the purpose of selecting a suitable device to lock off the source in plumbing and domestic heating?

a)

To ensure the source is securely isolated

b)

To increase water pressure

c)

To enhance heating efficiency

d)

To reduce energy consumption

33.

What should be done after securing the lock-off device?

a)

Increase the temperature

b)

Add a warning notice and retain the key

c)

Turn on the water supply

d)

Remove all safety equipment

34.

What is the purpose of using a multi-hole clasp in a lockout procedure?

a)

To allow multiple operatives to work on the same system with individual keys.

b)

To increase the security of the lockout system.

c)

To reduce the number of keys needed for the lockout.

d)

To ensure only one operative can access the system at a time.

35.

What additional protection does safe isolation provide besides preventing electrical shock?

a)

Prevents injury from mechanical movement.

b)

Ensures faster completion of tasks.

c)

Reduces the need for personal protective equipment.

d)

Increases the efficiency of the system.

36.

What is the first step to confirm that the power has been isolated?

a)

Check from live (phase) to earth.

b)

Check from neutral to earth.

c)

Check from live (phase) to neutral.

d)

Check from earth to live (phase).

37.

What should all tests confirm when checking for isolation?

a)

0 volts

b)

5 volts

c)

10 volts

d)

220 volts

38.

What is the final stage before carrying out your work ?

a)

Recheck the voltage indicator

b)

Test the water pressure

c)

Inspect the gas lines

d)

Check the temperature settings

39.

What is recommended to use for rechecking the voltage indicator?

a)

GS38 approved proving unit

b)

A standard multimeter

c)

A household battery

d)

A light bulb

40.

Is testing on a known live source recommended?

a)

No, it is not recommended

b)

Yes, it is always recommended

c)

Only if the voltage is low

d)

Only if the source is new